User manual MAXTOR CFP1060S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR CFP1060S. We hope that this MAXTOR CFP1060S user guide will be useful to you.


MAXTOR CFP1060S : Download the complete user guide (785 Ko)

Manual abstract: user guide MAXTOR CFP1060S

Detailed instructions for use are in the User's Guide.

[. . . ] Conner Filepro Performance Series CFP1060E/CFP1060S/CFP1060W Intelligent Disk Drive Product Manual Revision A May 1994 3081 Zanker Road San Jose, CA 95134-2128 (408) 456-4500 FCC Notice This equipment generates and uses radio frequency energy and, if not installed and used properly; that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, you are encouraged to try to correct the interference by one or more of the following measures: · · · Reorient the receiving antenna. [. . . ] A receptacle connector Amp P/N 111622-1 or equivalent can be used to connect a ribbon cable to this header. Table 4-6 defines the relationship between the jumpers and the SCSI ID: Table 4-7 Setting the SCSI ID Optional header Standard 0E1 E1 Out In Out In Out In Out In 0E2 E2 Out Out In In Out Out In In 0E3 E3 Out Out Out Out In In In In SCSI ID 0 1 2 3 4 5 6 7 Note: When controlling the SCSI ID remotely, In = Ground or TTL Low and Out = Open or TTL High. Page 34 Filepro CFP1060E/CFP1060S/CFP1060W SCSI Physical Characteristics Chapter 4 Disabling Spin-Up at Power On - CFP1060S A jumper in the E5 location, disables spin up after power-on for applications where spin up sequencing is necessary. An optional 2mm pin pitch right angle header is located on the front of the PCBA (opposite the SCSI interface connector) which can alternatively be used to disable spin up. Disabling spin up on application of power can also be enabled by setting the DSPN bit in MODE SELECT page 00H (Operating Parameters). The Host must issue a START UNIT command to cause the drive to spin up. Refer to the Ninth Generation SCSI Technical Reference Manual for additional information regarding the MODE SELECT and START/STOP UNIT commands. Refer to Figure 4-3 for the location of the Disable Spin jumper, E5 or 0E5. Table 4-8 Disabling Spin Up at Power-On E5 or 0E5 In In Out Out DSPN 0 1 0 1 Result Spin Disabled Spin Disabled Spin up on Power On Spin Disabled Note: In = Ground or TTL Low and Out = Open or TTL High. Delaying Spin Up at Power On - CFP1060S A jumper in the E6 location, delays spin up on power-up by the value of the drive's SCSI ID multiplied by 4 seconds (i. e. Delaying spin up on application of power can also be enabled by setting the SDLY bit in MODE SELECT page 00H (Operating Parameters). Refer to the Ninth Generation SCSI Technical Reference Manual for additional information regarding the MODE SELECT command. Refer to Figure 4-3 for the location of the Delayed Spin jumper, E6. Table 4-9 Delaying Spin Up at Power On E6 In In Out Out SDLY 0 1 0 1 Result Spin Delayed Spin Delayed Spin up on Power On Spin Delayed Technical Reference Manual Page 35 Chapter 4 SCSI Physical Characteristics Disabling the SCSI Bus Parity - CFP1060S SCSI parity is always enabled in both directions, unless the E7 Parity disable jumper is installed. Installing the jumper will cause the drive to ignore SCSI bus Parity In but it will continue to generate SCSI bus Parity Out. Disabling SCSI Bus Terminator Power (TERMPWR) - CFP1060S Power to the on-board terminators is provided by the higher of the voltage supplied at Pin #26, J2 or the voltage level at the 5 Volt power input to the drive minus one diode drop. Termination Power to external terminators can be supplied by the drive through Pin #26, J2. The TERMPWR line can be disconnected from the drive by removing Jumper E8. Table 4-10 Disabling SCSI Bus TERMPWR Jumper E8 In Out Result TERMPWR (J2, Pin #26) connected to the drive's internal termination power. TERMPWR (J2, Pin #26) open circuit. Page 36 Filepro CFP1060E/CFP1060S/CFP1060W SCSI Physical Characteristics Chapter 4 Setting the Bus Termination - CFP1060S This drive provides on-board Alternative 2 active termination for the SCSI bus. The termination resistors, which are contained in two Single Inline Packs (SIPs) should be removed from the drive unless it is a SCSI device at the physical end of the bus. Figure 4-4 shows the location of the terminator resistors. Figure 4-4 Terminator Resistor Locations Remove to Disable TERMPWR Input/Output SCSI Terminators. Remove in all but the last drive in the chain J1 J2 E8 F1 J3 SS LED J4 J6 100_4_2 TERMPWR Fuse NOTE: The TERMPWR output of the drive is protected by a 1 Ampere fuse. If external terminators are being powered from the drive and SCSI bus problems are suspected, verify that the fuse is still operational using a meter. Technical Reference Manual Page 37 Chapter 4 SCSI Physical Characteristics Cabling the Drive - CFP1060S Connect the SCSI interface cable and the spindle synchronization cable (when needed) as shown in Figure 4-5. Figure 4-5 Connecting the cabling J1 J2 50-pin SCSI Interface E8 Spindle Synchronization Connection J3 SS LED Key Pin 1 (typically indicated by a colored stripe on the cable J4 J6 Pin 1 4-pin Power Connector 100_4_3 SCSI Bus Cable The cable and mating connector required to connect the drive to the SCSI bus are described in Chapter 5. In addition, the cable should meet the following guidelines, particularly with FAST SCSI-2 systems: · · · · · · Do not route the data cable next to the drive PCB or any other high frequency or large current switching signals. The total cable length should not exceed 6 meters (20 feet) and may have to be reduced if a mixture of round and flat cable are used. [. . . ] The value reported for the number of sectors per track is dependent on the active notch value. Data Bytes Per Physical Sector: Defines the number of data bytes per physical sector. Track Skew Factor: Defines the number of physical sectors between the last logical block of one track, and the first logical block on the next sequential track of the same cylinder. Cylinder Skew Factor: Specifies the number of physical sectors between the last logical block of one cylinder and the first logical block on the next sequential cylinder. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR CFP1060S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR CFP1060S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.