User manual MAXTOR C2EIES3050

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR C2EIES3050. We hope that this MAXTOR C2EIES3050 user guide will be useful to you.


MAXTOR C2EIES3050 : Download the complete user guide (255 Ko)

Manual abstract: user guide MAXTOR C2EIES3050

Detailed instructions for use are in the User's Guide.

[. . . ] MATROX CORONA-II CAMERA INTERFACE APPLICATION NOTE SONY XC-EI30/50, ES30/50 OCTOBER 15, 2001 Basics about the camera Camera Descriptions § § § § § § 754 × 484 @ up to 60 fps. [. . . ] § Exposure time: The width (rising edge to falling edge) of the EXPOSURE1 (EXT. TRIG IN) signal plus a fixed internal camera delay of 1H to 2H equals the exposure time. The exposure time can be modified in the DCF using Matrox Intellicam or with the MIL digitizer control function MdigControl(). Refer to the appropriate manual or user guide for more information. COR2-CID-003 2 MATROX CORONA-II CAMERA INTERFACE APPLICATION NOTE SONY XC-EI30/50, ES30/50 OCTOBER 15, 2001 Specifics about the interface modes Camera Interface Details (continued) Mode 2: Asynchronous Reset (Restart/Reset mode) § Timing diagram: § Camera Switch settings: Internal/External synchronization switch and DIP switches are set as follows, refer to the camera manual for additional information: EXT Internal/External Sync ON * * * * INT ü OFF * * * * Shutter Speed 1 Shutter Speed 2 Shutter Speed 3 Shutter Speed 4 Field/ Frame/ 5 Mode 6 Mode 7 Mode 8 ü ü ü ü * Shutter switches are not effective in this mode Cabling details for this interface mode Cabling Requirements Mode 1: Continuous § Cable: DBHD44-TO-8BNC/O (open ended) cable required for video, synchronization and control signals. § Connection: Connections between the 12-pin connector of the camera and the 44-pin connectors of the Matrox Corona-II are as follows: CORONA2 (44-pin connector) Pin name VID1_IN GROUND Pin no. VIDEO OUTPUT GROUND 04 03 COR2-CID-003 3 MATROX CORONA-II CAMERA INTERFACE APPLICATION NOTE SONY XC-EI30/50, ES30/50 OCTOBER 15, 2001 Cabling Requirements (continued) Mode 2: Asynchronous Reset (Restart/Reset mode) § Cable: DBHD44-TO-8BNC/O (open ended) cable required for video, synchronization and control signals. § External trigger: TTL external trigger signal connected to the OptoCoupled Trigger input (pin 34, 35) of the DBHD44-TO-8BNC/O cable. § Connection: Connections between the 12-pin connector of the camera and the 44-pin connectors of the Matrox Corona-II are as follows: CORONA2 (44-pin connector) Pin name VID1_IN EXPOSURE1 GROUND OPTOTRIG + OPTOTRIG Pin no. [. . . ] Dorval, Quebec H9P 2T4 Canada Tel: (514) 685-2630 Fax: (514) 822-6273 COR2-CID-003 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR C2EIES3050




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR C2EIES3050 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.