User manual MAXON LV AIRFLO M BULLETIN

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXON LV AIRFLO M. We hope that this MAXON LV AIRFLO M user guide will be useful to you.


MAXON LV AIRFLO M BULLETIN: Download the complete user guide (1684 Ko)

Manual abstract: user guide MAXON LV AIRFLO MBULLETIN

Detailed instructions for use are in the User's Guide.

[. . . ] Low air stream oxygen levels can be tolerated without a need to add primary combustion air to the system. Modular burner design provides burner assembly configurations and total heat release for maximum application flexibility. [. . . ] LV-NP1 AIRFLO® burner with its gray iron body and #321 stainless steel mixing plates is the most economical choice for a raw gas burner system for fresh air heating with low heat release per lineal foot and outlet temperatures up to 540°C. LV-3G AIRFLO® burners have gray iron bodies and #321 stainless steel mixing plates. Four different versions are available, either for raw gas burner applications or those requiring a partial air/gas premixture system and/or outlet temperatures up to 540°C. LV-4D AIRFLO® burners have a ductile iron body and #310 stainless steel mixing plates for applications with outlet temperatures up to 815°C. LV-5D AIRFLO® burners complement their ductile iron bodies with Hastelloy-X mixing plates for use in applications with up to 930°C outlet temperature requirements. LV-5B AIRFLO® burners have an aluminum bronze body casting with Hastelloy-X mixing plates for use with applications requiring up to 930°C outlet temperatures. For upstream process air temperature up to 565°C. Typical burner data Fuel: natural gas at 15°C with 10. 9 kWh/Nm3 HHV - sg = 0. 6 [1] Combustion air: 15°C - 21% O2 - 50% humidity - sg = 1. 0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality. Burner size Maximum capacity per foot [2] Minimum capacity per foot [2] Natural gas differential pressure [3] Flame length [4] Pressure drop process air [5] kW kW mbar m mbar LV-NP1 175 9 10 0. 3 LV-3G 730 22 70 2 LV-4D 730 22 70 2 0. 5 - 6. 2 LV-5D 730 22 70 2 LV-5B 730 22 70 2 [1] sg (specific gravity) = relative density to air (density air = 1. 293 kg/Nm3) [2] Maximum and minimum capacities are highly dependent upon the application. Check "Specifications of LV AIRFLO burners" for more information. [3] Natural gas differential pressure at burner inlet at maximum stated burner capacity. Refer to "Specifications of LV AIRFLO burners" for gas differential pressures to be used with alternative gas drillings. [. . . ] If correctly used within the performance limits as described on page 4-21. 4-7, both CO and NOx will remain far below the limits as determined in most standards. Contact MAXON for information on installation specific estimates or guarantees. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXON LV AIRFLO M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXON LV AIRFLO M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.