User manual MAXON DM-0530 SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXON DM-0530. We hope that this MAXON DM-0530 user guide will be useful to you.


MAXON DM-0530 SERVICE MANUAL: Download the complete user guide (3186 Ko)

Manual abstract: user guide MAXON DM-0530SERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] All rights reserved. 4 - 21. 4 - 8 E - i - 11/10 Duct burners - LV AIRFLO® Burner capacity versus gas pressure - LV-3, -4 & -5 AIRFLO® burners Capacity vs. gas pressure 3. 0 2. 5 Firing Rate Per Foot (MBtu/h) 2. 0 1. 5 1. 0 0. 5 0. 0 0 5 10 15 Gas Pressure ("wc) 20 25 30 Gas pressures are valid for use with natural gas with 1000 Btu/ft3(st) high heating value. Pressures are valid for burners with standard drilling (24 drillings/foot). The use of alternative drillings will lower the required gas pressure for a given burner capacity. www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. [. . . ] Also, the offtake should be welded on the manifold in such a way that the smaller pipe does not stick into the main manifold (saddle weld), thus avoiding turbulence at the take-off point (see Fig. The manifold should continue at least 2 pipe diameters beyond the last take-off (see Fig. 4). 2 3 4 X 2X www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. Duct burners - LV AIRFLO® Fuels Series LV AIRFLO® burners produce clean and odor-free combustion with natural gas, propane, butane and hydrogen. 4 - 21. 4 - 23 E - i - 11/10 Expected emissions Emissions are highly influenced by different burner and process-related factors, such as type of gas, burner capacity, air stream velocity, process air humidity and temperature, relation to duct/profile plate area, etc. We strongly advise to contact MAXON for evaluation of expected emissions on your typical application. Contact MAXON for specific evaluation of your process and application for a written guarantee of emissions. www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. 4 - 21. 4 - 24 E - i - 11/10 Duct burners - LV AIRFLO® Dimensions Burner sections Burner type A B Dimensions in inches unless stated otherwise C D [1] E A LV-NP1 6. 84 7. 0 1. 06 2. 19 3. 38 C B E D [1] For 12" back inlet section only Burner type A B Dimensions in inches unless stated otherwise C D E F G A LV-3, -4, -5 7. 44 7. 5 1. 94 4. 12 2. 62 1. 125 1. 5 B F GD E C Burner type A Dimensions in inches unless stated otherwise B C D E F A LV-3, -4, -5 back inlet sections 7. 44 7. 5 1. 94 4. 12 2. 62 5 B FD E C www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. Duct burners - LV AIRFLO® 4 - 21. 4 - 25 E - i - 11/10 Designation Dimensions in inches unless stated otherwise Dimensions A LV-NP1-6 A 6 B LV-NP1-12 B 12 C LV-NP1-18 C 18 D LV-NP1-24 D 24 E LV-NP1-12B E 12 F NPT 1-1/2" F www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. 4 - 21. 4 - 26 E - i - 11/10 Duct burners - LV AIRFLO® Designation LV-3G-6 LV-4D-6 LV-5D-6 LV-5B-6 Dimensions in inches unless stated otherwise Dimensions A A 6 LV-3G-12 LV-4D-12 LV-5D-12 LV-5B-12 B B 12 LV-3G-T LV-4D-T LV-5D-T LV-5B-T C C 12 LV-3G-X LV-4D-X LV-5D-X M 12 N 3. 5 LV-3G-12B LV-4D-12B LV-5D-12B LV-5B-12B 1 D 12 E 5 1) Connection for optional back inlet flange LV-3G-BX LV-4D-BX LV-5D-BX 1 M 12 N 3. 5 1) Connection for optional back inlet flange LV-3G-BH LV-4D-BH LV-5D-BH G 19. 44 H 12 J 4. 88 K 3. 72 1) Connection for optional back inlet flange 1 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. Duct burners - LV AIRFLO® Optional back inlet flanges 4 - 21. 4 - 27 E - i - 11/10 For 12B and 36BH sections C Dimensions in inches unless stated otherwise A B C Size [1] 2" 0. 88 5. 75 3" 1. 75 5. 75 [1] Available in NPT or ISO threads For 12 x 12 BX sections C B Dimensions in inches unless stated otherwise A B C Size [1] 3" 3. 5 7 4" 3. 5 7 [1] Available in NPT or ISO threads www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. 4 - 21. 4 - 28 E - i - 11/10 Duct burners - LV AIRFLO® End plates for Series LV-NP1 AIRFLO® burners All open ends of the burner assembly must be closed off with one of these end closures or pilots. 2. 03 0. 38 1. 0 0. 062 Externally mounted spark electrodes for LV-3 AIRFLO® burners B A C D E F Dimensions in inches unless stated otherwise A B C D E F [1] 1/2"-14 5/16" hex 2. 5 0. 72 1. 03 18 thd [1] Maximum length - to be cut to the correct size for each application Externally mounted spark electrodes for LV-4 & LV-5 AIRFLO® burners C D A E G F B Dimensions in inches unless stated otherwise A B C DØ E F G gap 12 13. 8 18 19. 8 15/16" 1. 0 1. 562 0. 938 0. 062 hex 24 25. 8 36 36. 2 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. Duct burners - LV AIRFLO® Quartz ignitor 4 - 21. 4 - 35 E - i - 11/10 Grip nut, o-ring seal, shield tube and ignitor nut are packaged separately to prevent damage to the quartz assembly during transit. The end user is responsible for final assembly of the quartz ignitor before installation. Dimensions in inches unless specified otherwise 1) Rubber cover 2) Grip nut 3) Ignitor nut 4) Shield tube 1. 0 Ø 5) 3/4-10 UNC 1 4 5 A 2 B 3 C Electrode 12" 18" 20" 24" 30" 36" 42" 48" A 1. 2 0. 83 1. 39 1. 39 0. 99 1. 64 0. 8 0. 8 B 12. 1 18. 5 19. 9 23. 9 30. 3 36. 7 42. 5 48. 5 C 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 0. 78 Flame rod For those Series LV AIRFLO® burners using flame rods, most applications are covered by one of two sizes (specific number depends on nominal length "D" of rod extension). These may need to be cut to dimension "C" depending on your particular application. A B C D Dimensions in inches unless stated otherwise Burner model A B C D 7. 125 7. 125 LV-3G, -4D, -5D dir. 18 24 Division plate Provides isolation of burner feed(s) where desirable. This enables staging of burners for increased burner turndown. LV-NP1 LV-3, LV-4, LV-5 www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. 4 - 21. 4 - 36 E - i - 11/10 Duct burners - LV AIRFLO® USB burner support bracket Normally used in pairs as shown below. Two versions are available: zinc plated carbon steel for maximum inlet temperature up to 750°F or 304 SS for maximum inlet temperature up to 1600°F. A C B D Dimensions in inches unless stated otherwise A B C D hole E 0. 88 4. 25 4. 19 0. 75 3. 0 E Profile plate mounting bracket On certain high temperature rise applications of AIRFLO® line burners, it is advantageous to partially close off the square or rectangular openings within the burner assembly in addition to installing the profile plate around the outside of the burner in order to increase the velocity sufficiently. The stainless steel profile mounting plate bracket, illustrated in the sketches below, is used to support plates for this purpose. The plate used to close off a portion of the opening will need to be sized for each individual application. 1) Dia. = 1/4" 2) Profile plate mounting bracket 3) Profile plate www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. [. . . ] Sketch 5 shows MAXON USB support brackets suspending the burner from an overhead angle iron. Sketch 6 shows an alternate arrangement which offers the advantage of more controlled positioning. www. maxoncorp. com combustion systems for industry Maxon reserves the right to alter specifications and data without prior notice. All rights reserved. 4 - 21. 4 - 42 E - i - 11/10 Duct burners - LV AIRFLO® Start-up instructions Instructions provided by the company or individual responsible for the manufacture and/or overall installation of a complete system incorporating MAXON burners take precedence over the installation and operating instructions provided by MAXON. If any of the instructions provided by MAXON are in conflict with local codes or regulations, please contact MAXON before initial start-up of equipment. Read the combustion system manual carefully before initiating the start-up and adjustment procedure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXON DM-0530




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXON DM-0530 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.