[. . . ] SP1200 Single-Channel Program Controller/Amplifier
Instruction Manual
ZONE A
MASTER VOLUME
INPUTS
3 0 3 6 9 15 30 55
SP1200 MUSIC CONTROLLER
OL
ON
1
2
3
4
OFF
STATUS
COMM PORT
POWER
DIRECT
PROGRAM INPUTS
L GROUND ALL CALL PARALLEL INPUTS G+ R
PAGING MIC
ZONE A
SP1200 MUSIC CONTROLLER
LOCAL
1 2 3 4
PHANTOM CONTROL
GAIN +40dB GAIN LOW
U
HIGH
U
12345678
PRIORITY
1234
EXPANSION IN
115V 60Hz FUSE 115/ T4A 120 WATTS 230V 50Hz FUSE 230/ T2A 120 WATTS
EXPANSION OUT
1
2
3
4
OUTPUT
1
2
3
4
ON
-
+
12 +12
12 +12
REMOTE
CAUTION: TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING
ZONE A
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC "MACKIE. ", "MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. · WOODINVILLE · WA · MADE IN USA · FABRIQUE AU USA OUTPUT SUITABLE FOR CLASS 2 WIRING + 100/70V/8
A G B
MIC/LINE INPUT A
PHANTOM GAIN +40dB
PAGING MIC VOX
PRE OUT
PROGRAM EQ
LOW 80Hz
U
MID
U
400
FREQ
1K 3K 250 8k
HIGH 12k
U
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING:
SERIAL NUMBER
MANUFACTURING DATE
1
2
3
G
+
GAIN
LOW
U
HIGH
U
1234
I 0
12345678
AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. [. . . ] The REMOTE connector is wired as follows: Pin 1 = Ground (Shield) Pin 2 = Data + (with +24V DC power) Pin 3 = Data (with +24V DC power) Note: See the instructions with the remote control for more information.
For local interconnection of the Expansion Bus, the use of standard computer cable with an overall shield is acceptable, such as Belkin Pro Series 25Conductor Straight-Through Cable Assembly (Part Number F3D111-06) or equivalent. Ensure that the cable is wired straight-through and terminated to DB25M connectors on each end. Note: The use of ribbon cable is permissible for these connections, only where the total length of each cable is 12" (30cm) or less.
EXPANSION I/O
15VDC (w/J2 INSTALLED) N/C PAGING MIC (+) INPUT 4 RIGHT (+) INPUT 4 LEFT (+) INPUT 3 RIGHT () INPUT 3 LEFT () GROUND INPUT 2 RIGHT (+) INPUT 2 LEFT (+) INPUT 1 RIGHT () INPUT 1 LEFT () 25 13 +15VDC (w/J3 INSTALLED) PAGING MIC CONTROL PAGING MIC () INPUT 4 RIGHT () INPUT 4 LEFT () GROUND INPUT 3 RIGHT (+) INPUT 3 LEFT (+) INPUT 2 RIGHT () INPUT 2 LEFT () GROUND INPUT 1 RIGHT (+) INPUT 1 LEFT (+)
14
1
SP1200 12
Connecting the RS485 Serial Port
This is a 3-pin Phoenix-type connector that follows standard RS485 protocol. Select either a data-grade shielded twisted pair cable or a standard 3-conductor microphone cable for this connection. The RS485 port is wired as follows: Pin 1 = A (non-inverting I/O) Pin 2 = G (Ground) Pin 3 = B (inverting I/O) The SPLinker Sound Palette Control PC application uses the RS485 serial port to connect between a computer and the SP1200. Connect the PC RS485 port to the first SP1200, and then interconnect up to two SP1200s in the system using their RS485 connections. Note: It may be necessary to install an RS485 interface card in the PC, or to use an RS232 to RS485 converter. Two SP1200s can be connected together for stereo operation (each SP1200 assigned the same AMP ADDRESS, with one assigned Master, and the other Slave).
Program Input Source has four corresponding switches: Left (+), Left (), Right (+), and Right (). Typically, you would move all four switches either down (off) or up (on to assign to expansion bus). Note: These DIP switches can be accessed without removing the cover of the unit. A flathead screwdriver at least 2" (50. 8 mm) long, and no larger in diameter than 1/8" (3. 175 mm) is required. CAUTION: When using multiple SP1200s that use the expansion bus, these switch settings must be unique to each unit or you can damage your SP1200(s). Never assign more than one program source to the same channel on the Expansion Bus.
Insert screwdriver through grill hole to adjust DIP switches. Use a flashlight to aid in viewing the DIP switches.
Approximate location of Bus Assign DIP switches.
RS485
RS485
or
Laptop with SPLinker PC Application
RS485
Bus Assign DIP Switch Location
REAR PANEL
Internal Settings
ON ON 12345678 12345678
J12 J11 J10 J9
J8
S3
Note: There are several settings that can be changed inside the SP1200. CAUTION: These servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Make sure the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP1200.
SP1200 INPUT BOARD
S2
S1
Signal Input 1 Left (+) Input 1 Left () Input 1 Right (+) Input 1 Right () Input 2 Left (+) Input 2 Left () Input 2 Right (+) Input 2 Right ()
Switch No. S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8
Signal Input 3 Left (+) Input 3 Left () Input 3 Right (+) Input 3 Right () Input 4 Left (+) Input 4 Left () Input 4 Right (+) Input 4 Right ()
Switch No. S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 S2-7 S2-8
Bus Assign
There are two 8-position DIP switches on the Input Board that allow you to assign a Program Input source to the balanced expansion bus. Each
Bus Assign Switch Chart
SP1200 13
EQ Bypass
Jumper J6, located on each Filter Board, allows you to bypass the 3-band EQ for the four Program Inputs. Note: The top Input Board must be removed in order to access Jumper J6 on the Filter Board.
On the Amplifier Board J1 Jumper pins 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2 Jumper pins 1 and 2 for 100V or 8/250W operation Jumper pins 2 and 3 for 70V or 8/150W operation J3 Jumper pins 1 and 2 for 70V or 8/150W operation Jumper pins 2 and 3 for 100V or 8/250W operation J4 Jumper pins 1 and 2 for 70V or 8 ohm operation Jumper pins 2 and 3 for 100V operation J9 Jumper pins 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation
R134 R137
C94 C95 C96
J1 J2 D3 D22 C23 U25
SP1200 FILTER BOARD
C40
C54
R121
Q1 L6 S1 L2 L4 J7 L3 L5 J8
EQ BYPASS
1
R96
EQ ENGAGE
3 2
R97
L10
J6 C91
L7 L9 R132
J9 R147 R142
C92 C93 R145
R148 R146
R149 S2
J10 Jumper pins 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation J11 Jumper pins 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation J15 Jumper pins 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation
R133
EQ Bypass Internal Jumper
70V/100V/8 Ohm Settings
There are several jumpers on the Amplifier Board that are used to configure the amplifiers for use with a 70V distributed system, a 100V distributed system, or an 8-ohm load. The SP1200 is shipped with the jumpers set for 70 Volt operation in U. S. [. . . ] boxes), daytime phone number, Return Authorization Number, and a detailed description of the problem, including how we can duplicate it. Write the Return Authorization Number in BIG BOLD PRINT on the top of the box. Ship to this address:
MIC/LINE INPUT GAIN LOW HIGH PHANTOM GAIN +40dB MIC VOX PROGRAM EQ LOW MID FREQ HIGH INTERNAL BUS ASSIGN (S1/S2)
Mackie Industrial Service Department 16140 Wood-Red Road NE, Suite 5 Woodinville, WA 98072
NOTE: All SP1200s sold in the U. S. and Canada are configured for 115 VAC line input and 70V speaker output. [. . . ]