User manual M-AUDIO OXYGEN 49 (BLUE)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual M-AUDIO OXYGEN 49 (BLUE). We hope that this M-AUDIO OXYGEN 49 (BLUE) user guide will be useful to you.


M-AUDIO OXYGEN 49 (BLUE) : Download the complete user guide (1541 Ko)

You may also download the following manuals related to this product:

   M-AUDIO OXYGEN 49 (BLUE) (1557 ko)
   M-AUDIO OXYGEN 49 (BLUE) (1546 ko)
   M-AUDIO OXYGEN 49 (BLUE) GUIDA RAPIDA (409 ko)
   M-AUDIO OXYGEN 49 (BLUE) MANUALE DELL'UTENTE (1981 ko)
   M-AUDIO OXYGEN 49 (BLUE) QUICK-START-ANLEITUNG (414 ko)
   M-AUDIO OXYGEN 49 (BLUE) GUIDE D’UTILISATION (1551 ko)
   M-AUDIO OXYGEN 49 (BLUE) GUIDE DE PRISE EN MAIN (376 ko)
   M-AUDIO OXYGEN 49 (BLUE) GUÍA DE INICIO RÁPIDO (404 ko)
   M-AUDIO OXYGEN 49 (BLUE) クイックスタートガイド (534 ko)
   M-AUDIO OXYGEN 49 (BLUE) ユーザーズ・マニュアル (1660 ko)
   M-AUDIO OXYGEN 49 (BLUE) QUICK START GUIDE (381 ko)
   M-AUDIO OXYGEN 49 (BLUE) DIRECTLINK FOR CUBASE README (785 ko)
   M-AUDIO OXYGEN 49 (BLUE) CONTROLLING REASON FROM OXYGEN (64 ko)
   M-AUDIO OXYGEN 49 (BLUE) DIRECTLINK FOR GARAGEBAND AND LOGIC README (78 ko)

Manual abstract: user guide M-AUDIO OXYGEN 49 (BLUE)

Detailed instructions for use are in the User's Guide.

[. . . ] M-AUDIO Oxygen Series User Guide Oxygen Series User Guide 2 1 Introduction Congratulations on purchasing an M-Audio Oxygen Series keyboard. Oxygen keyboards now offer DirectLink, which provides support for Digital Audio Workstations (DAW)1 such as Pro Tools 8 by automatically mapping the track and master volume sliders, slider buttons, pan knobs and transport controls to their corresponding functions in the program. A single USB connection not only sends MIDI data to the computer, but also provides power to the keyboard. All Oxygen Series keyboards function as class-compliant devices and will be recognized by your computer without the need to install additional drivers. [. . . ] Appendix A lists the standard MIDI CC numbers from 0 to 127 and their corresponding General MIDI parameters. Appendix B lists the additional, M-Audio specific MIDI assignment options (128 - 255), grouped by control type (sliders & knobs / buttons & sustain pedal jack), as well as their corresponding data type and purpose. NOTE: Your Oxygen keyboard never transmits values outside the range specified by the MIDI protocol (0-127). The controller numbers from 128 - 255 are only used internally by your Oxygen keyboard. This simplifies configuration of the knobs, buttons and sliders when assigning advanced MIDI messages, and allows additional configuration options for the controls (for example, setting Trigger or Toggle operation of a button). Oxygen Series User Guide 4 Setting Toggle Values (Min/Max) for Buttons or the Sustain Pedal When standard MIDI CC numbers are assigned to buttons or the Sustain pedal, they will toggle between two values. This means that one value is sent the first time it is pressed, and another value is sent the next time it is pressed. By default, the buttons on your Oxygen Series keyboard are already configured to operate as toggle switches. When configuring a button or the sustain pedal to operate in toggle mode, the following three values need to be specified: Key Control Assign (example) Data 2 (example) Data 3 (example) Parameter MIDI CC number Second press First press 10 (Pan) 0 (minimum) 127 (maximum) Value The following example will configure a button to "hard pan" the sound to the left speaker when it is pressed the first time, and "hard pan" to the right speaker when it is pressed a second time: 1. Select a button as described earlier in this guide Press the Advanced button Press the Control Assign key Type 10 using the number keys. See Appendix A Press the Enter key Press the Advanced button Press the Data 2 key Type 0 using the number keys to assign the "second button press" (minimum) value Press the Enter key Press the Advanced button Press the Data 3 key Type 127 using the number keys to assign the "first button press" (maximum) value Press the Enter key TIP: It can be useful to transmit two other specific values instead of sending minimum (zero) and maximum (127) values as in the above example. When assigning a button to control Pan (MIDI CC 10), you can, for example, configure Data 2 to send value 38, and Data 3 to send value 93, effectively causing pan to switch between the approximate "ten o'clock" and "two o'clock" positions when pressing the button repeatedly. NOTE: If you want the button to send the same value every time it is pressed, enter the same value for both the Data 2 and Data 3 parameters. Oxygen Series User Guide 5 Setting Trigger Values for the Buttons or the Sustain Pedal It is possible to set a Trigger Value for a button or the sustain pedal, causing it to send one value when pressed and held down, and another value when released. The sustain pedal is already configured to send trigger values by default, ensuring it activates the sustain effect when pressed and deactivates it when the pedal is released. Buttons can also be configured to operate this way, which requires four values to be specified. At the example of the sustain pedal, these four values are: Key Control Assign Data 1 (example) Data 2 (example) Data 3 (example) Parameter Trigger On/Off operation MIDI CC number Button/Pedal Released Button/Pedal Pressed 146 64 (Sustain) 0 (minimum) 127 (maximum) Value NOTE: When working with proprietary M-Audio parameters from the 128-255 range, the "Control Assign" setting is used to configure a button or the sustain pedal for this special mode of operation. This means that certain values that are usually specified through the "Control Assign" setting must instead be specified via the "Data 1" parameter (such as the standard MIDI CC parameter in the example below). The following example will configure a button to "hard pan" the sound to the right speaker when it is held down, and "hard pan" to the left speaker when it is released. This involves configuring the button to operate as a trigger, while controlling the Pan parameter (MIDI CC 10): 1. Select a button as described earlier in this guide Press the Advanced button Press the Control Assign key Type 146 using the number keys. See Appendix B Press the Enter key Press the Advanced button Press the Data 1 key Type 10 using the number keys. See Appendix A Press the Enter key Press the Advanced button Press the Data 2 key Type 0 using the number keys. In other words, sound will be panned "hard left" when the button is released. Press the Enter key Press the Advanced button Press the Data 3 key Type 127 using the number keys. [. . . ] Modifications not authorized by the manufacturer may void users authority to operate this device. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE M-AUDIO OXYGEN 49 (BLUE)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual M-AUDIO OXYGEN 49 (BLUE) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.