User manual M-AUDIO FAST TRACK C600

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual M-AUDIO FAST TRACK C600. We hope that this M-AUDIO FAST TRACK C600 user guide will be useful to you.


M-AUDIO FAST TRACK C600 : Download the complete user guide (2372 Ko)

You may also download the following manuals related to this product:

   M-AUDIO FAST TRACK C600 (2047 ko)
   M-AUDIO FAST TRACK C600 (2413 ko)
   M-AUDIO FAST TRACK C600 (2283 ko)
   M-AUDIO FAST TRACK C600 (2329 ko)
   M-AUDIO FAST TRACK C600 (2456 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)
   M-AUDIO FAST TRACK C600 QUICK SETUP GUIDE (2059 ko)

Manual abstract: user guide M-AUDIO FAST TRACK C600

Detailed instructions for use are in the User's Guide.

[. . . ] Fast Track C600TM User Guide ® Legal Notices This guide is copyrighted ©2011 by Avid Technology, Inc. , with all rights reserved. Under copyright laws, this guide may not be duplicated in whole or in part without the written consent of Avid. Avid, the Avid logo, Fast Track, M-Audio and Pro Tools are either trademarks or registered trademarks of Avid Technology, Inc. All other trademarks contained herein are the property of their respective owners. [. . . ] Note that when using the interface with an ASIO or CoreAudio application, the sample rate can also be determined by your audio application. This parameter may not be editable from within the Fast Track C600 Control Panel if your audio application is running. In this case, any changes to the sample rate must 22 Fast Track C600 User Guide will hear pops, clicks, and stuttering in your audio streams. On the other hand, if the buffer size is set too high, your computer will process audio without incident, but your software will feel sluggish and unresponsive. To find your system's optimum buffer size setting, begin with a high setting and gradually reduce the size until you begin to hear clicks, pops, or other audible glitches in your audio. You may need to stop playing audio any time you change this setting and certain applications will require you to relaunch the program before the new buffer size settings become active. Load Clock Settings from Settings Files When this option is selected, the clock source and buffer settings are recalled when loading a settings file. By leaving this box unchecked, you can load custom settings files with different lowlatency mixer configurations, without inadvertently changing the buffer size or clock source settings of the device. Post-Fader Meters When this option is selected, the meters will display levels after the channel fader. This means fader positions will affect what you are seeing on the meters. This menu only appears on Windows systems. Most Mac OS X applications allow to change the buffer size from within the audio application itself. Please see your audio application's user guide to learn how to change this setting. Pre-Fader Meters When this option is selected, the meters display the level of a signal before it passes the fader. This allows signal levels to be displayed regardless of the fader positions within the stereo mix (in other words, a fader can be all the way down and no sound will be heard from the mixer's output, but you can still see if there is any activity on that input). Multi Button Settings Fast Track C600 has a Multi button, and five assignable Transport buttons which can be programmed as described in Chapter 6, "The Multi Button and Transport Buttons. " FX Sends Mode Pre-Fader FX Sends Driver Control Panel Options Hold Clipping Indicators until Clicked The top section of the meters (or right section for horizontal meters) of the Driver Control Panel feature a red clipping indicator. When this option is selected, the clipping indicators will remain lit until they are clicked. When Pre-Fader FX Sends is selected, the full audio signal will be sent to the FX Sends, regardless of the position of the Channel Faders of stereo mix 1­2. Post-Fader (Mix 1/2) FX Sends When Post-Fader (Mix 1/2) is selected, the audio signal level being sent to the FX Sends will be affected by the position of the Channel Faders of Stereo Mix 1. Chapter 5: The Driver Control Panel 23 Flow Clicking the Flow button opens a display showing the signal flow from the inputs to the outputs of Fast Track C600. This is a useful reference for understanding the path of an audio signal flowing through Fast Track C600. Firmware and driver information Web links Viewing Firmware and Installer Information In this section, you can view the firmware version of the Fast Track C600 hardware, and the package version of the Fast Track C600 driver installer. About The About pop-up menu allows you to view the firmware version of the Fast Track C600 hardware, and provides convenient web links to product documentation, updates, support, FAQ, and registration. Accessing the Web Links Along the bottom-right of the Driver Control Panel you can easily access helpful online resources on our website (www. m-audio. com) by clicking on the following pop-up menus: · Manual · Updates · Support · FAQ · Register Your computer must be connected to the Internet in order for these links to work. 24 Fast Track C600 User Guide Monitor Mixes The monitor mixer allows you to create four different stereo mixes from 14 input sources consisting of any of the hardware inputs (4 analog and 2 digital inputs) and software returns (8 software returns). This allows you to set up nearzero latency cue mixes in which the performers hear a "customized" mix while recording. It is important to note that any changes made to the monitor mix will only affect what is audible from the mixer's outputs--the monitor mix does not affect the signals that are sent to your software for recording. For example, if you are recording a vocalist and they tell you to turn up the vocal track so they can hear themselves better, you can increase the vocalist's microphone channel in the monitor mix. This will make the vocal part louder in the vocalist's headphones, but it will still be recorded into your software at the volume determined by the top panel Gain Knob. The monitor mixer is set up like a standard mixing console: There are 14 channels (6 hardware inputs and 8 software returns), each with its own volume fader, pan and aux send knobs, solo, and mute buttons, as well as a master output section with its own fader. A pair of channels can be linked together by clicking the link icon between the two channels. Linking channels allows you to adjust mute, solo, and fader settings simultaneously by modifying parameters on either one of the linked channels. However, linking two channels will not have any effect on their Pan controls, which are always made on a per-channel basis. The monitor mixer features high-resolution meters to show input channel levels (directly above each channel) and main mixer output levels (at the top right of the mixer). The pre/post fader metering operation can be set from the Settings Tab of the Control Panel. [. . . ] The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city recycling office or the dealer from whom you purchased the product. Recycling Notice Appendix B: Compliance Information 41 EMC (Electromagnetic Compliance) Avid declares that this product complies with the following standards regulating emissions and immunity: · FCC Part 15 Class B · EN 55022 Class B · EN 55024 Class B · AS/NZS CISPR 22 Class B · CISPR 22 Class B CE Compliance (EMC and Safety) Avid is authorized to apply the CE (Conformité Europénne) mark on this compliant equipment thereby declaring conformity to EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC. FCC Compliance for United States Radio and Television Interference Communication Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE M-AUDIO FAST TRACK C600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual M-AUDIO FAST TRACK C600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.