User manual LOWRANCE X-85

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOWRANCE X-85. We hope that this LOWRANCE X-85 user guide will be useful to you.


LOWRANCE X-85 : Download the complete user guide (538 Ko)

Manual abstract: user guide LOWRANCE X-85

Detailed instructions for use are in the User's Guide.

[. . . ] X-75 and X-85 INSTALLATION AND OPERATION INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION - BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPEED/TEMPERATURE SENSORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] As you press the key, the menu's bar graph will grow wider and the percentage will increase in value. To erase the menu, press the EXIT key. RANGE - Automatic When turned on for the first time, the unit automatically places the bottom signal in the lower half of the screen. Typically, the range cannot be changed manually while the unit is in automatic, as shown at right. However, depending upon the bottom depth and the current range, you can change the range to a different depth. In the example screen shown below, the bottom depth has descended to a point where you can change the range to 150 feet. To do this, simply press the right arrow key while the Auto Range menu is displayed. When you're finished with this menu, press the EXIT key to erase it. RANGE - Manual You have complete control over the range when the sonar is in the manual mode. To change the range, first make certain the unit is in the manual mode. Next, press the MENU key and the up or down arrow keys until the range menu appears as shown at right. The available ranges are 0-5, 10, 20, 30, 40, 60, 100, 150, 200, 300, 500, 800, and 1000 feet. After the desired range is displayed, press the EXIT key to erase the range menu. NOTE: The depth capability depends on the frequency selection, transducer installation, water and bottom conditions, and other factors. UPPER AND LOWER LIMITS You can enter any range when the unit is in the manual mode. The unit lets you enter any upper and lower limit, provided there is at least five feet separating them, for example, from 20 to 25 feet. (On the screen below left, the upper limit is 0 and the lower limit is 60. ) Using the upper and lower limit range option, we changed the range from 0 to 60 feet to 24 to 54 feet. This "zoomed" the display to a 30 foot range. As you can see, the fish arches near the bottom are much larger and easier to see. In fact, a possible fish on the bottom shows on the enlarged screen that is not even visible on the left!Not only does this make it easier to see targets, but you can more accurately determine their depth, due to the expanded depth range. Next, make certain the unit is in the manual mode, then press the up or down arrow keys until the "Set Chart Limits" menu appears as shown below. Now press the left arrow key to change the upper limit or the right arrow key to change the lower limit. After pressing the key, a screen similar to the one at the top of the next page appears. In this example, we're setting the upper limit. Use the up and down arrow keys to select the number, the right and left arrow keys to move to the next number. The screen shown below appears. As you can see, the upper limit has changed from 0 to 35 feet. With the lower limit remaining at 60 feet, this gives a "zoom" of 25 feet. [. . . ] You will be asked for your unit's serial number. 800-324-1356 Canada Only. Central Time. How to Obtain Service (International Customers Only) If you need service or repairs, contact the dealer in the country you purchased your unit. WARRANTY REPAIR WILL BE HONORED ONLY IN THE COUNTRY UNIT WAS PURCHASED. Please follow the shipping instructions shown below on this page if you have to mail your unit to the dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE X-85




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE X-85 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.