User manual LOWRANCE X-5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOWRANCE X-5. We hope that this LOWRANCE X-5 user guide will be useful to you.


LOWRANCE X-5 : Download the complete user guide (1541 Ko)

You may also download the following manuals related to this product:

   LOWRANCE X-5 OPERATION MANUAL (636 ko)

Manual abstract: user guide LOWRANCE X-5

Detailed instructions for use are in the User's Guide.

[. . . ] Digital Averaging Battery Backup Scale On/Off Calibrate Speed Test Pattern Keel Offset Total System Reset Transducers and ConeAngles Signal Interpretation Fish Signals Surveying a Lake Bait Fish How to Obtain Service How to Obtain aSchematic 32 32 32 32 33 33 33 33 34 35 36 36 37 38 40 40 41 41 PDF compression, 44OCR, web-optimization with CVISION's PdfCompressor The Lowrance X-5 Liquid Crystal Sonar(LCG) is the most sophisticated and reliable instrument of its kind. This unit is so advanced, you can just press the "ON" button and let it do all the work. However, taking manual control enables you to open up a wholeworld of features not available in other sonars. Thisis where it all begins, and improper installation can cause problems down the road. Afteryou've read these instructions and installedyour X-5, read the rest of this manual in detail. [. . . ] KEYS TO ADJUST VOLUME(the sensitivitykeys are used to adjust thevolume ofthe speaker) and the speaker will begin beeping. Pressing the right arrow key will increasethevolume, the leftarrow key decreases it. Thesensitivitybarwill move to the right or left, signifying the volume level. The speaker will stop beeping six seconds afterthe last key has been pressed. To view the chart speed withoutchanging it press 2nd, STOP!The sensitivity bar will disappear and the chart speed bar will replace it for a six seconds. At times it is desirable to stop or "freeze" the display to examine an echo before it scrolls off the 'screen. Pressing the STOP/RESUMEkey once will freeze the display. In the upper leftcornerof thedisplay, the word "AUTO" will chsnge to "STOP" to signify that the X-5 is in the "freeze" mode. Pressing STOP/RESUMEagain will start the display moving at the last chart speed setting. If the digital sonar is on, the bottom depth will continueto bedisplayed on thescreen. Thedigital does notstop whenthe chart is in the "freeze" mode. 5= CLEAR DIST LOG SCALE MARKERS There are ten scale markersprinted on both sides of theX-5'sdisplay to help you determine what the depth of a target is. For example, if the range is 0-60feet, and a target (such as a fish) was displayed next to the fifth line, then it is 30feet deep. 5 lines times 6 feet per line = 30 feet)This method works no matter what the upper and lowerlimits are, but to make it easier useupper and lower limits in multiples often, i. e. 10, 20, 30, etc. The distance log will start operating from the time the X-5 is first turned on. With an upper limit of 0 and a lower limit of 60, then each scale mark is 6 feet which places the fish at approximately54 feet. Since FASTRAK is so close to the scale markers, it makes it a little easier to line up the target's depth with the scale. To turn FASTRAK off, press the 1 key. 31 14 PDF compression, OCR, web-optimization with CVISION's PdfCompressor COMMAND The X-5 has manymore featuresthan available keys. TheCOMMAND key lets you access "menus" of otherfunctions. A typical menu looks like figure 29 To find the desired function, press 2nd, DISC (COMMAND). If you don't see the desired function, press the DISC (COMMAND)key again. Continue pressing it until the desired function is shown on the display. All of the functions will be numbered. To activate the desired function, simply press the numberon the keyboard that corresponds to the function. A faster way to execute menu functions is to press the function's numberfirst then press 2nd, DISC (COMMAND). To clear the log one must either press 2nd, DISC (COMMAND), then press DISC (COMMAND) until the CLEAR DISTANCE LOG function is displayed and press the number 5 on the keyboard, or simply press 5, 2nd, DISC (COMMAND). Both methods can be used on all menufunctions. Manual Operation The lower limit may be changed to anysetting whilethe X-5 is in the manualmode, regardlessof where the bottom signal is. To changethe lower limit in manual mode, firstmake certain the word "AUTO" is not displayedat the top of the screen, signifying that the automatic mode is off. [. . . ] If you wish to view the zone alarm bar, simply press either the SHALLOWSET or DEEP SET keys and the bar will be displayed for six seconds. To turn it back off, simply press 2nd, downarrow (DISPLAY) again. Ifthe zonealarm issetoff bya fish orthe bottom, the alarm will sound and the words ZONE ALARM will flashat the bottom of the display. If the range is changed, thezonealarm may need to be changed too, since it does not track range settings. CLEARING THE ZONE ALARM DISCRIMINATION OFF DISCRIMINATION ADJUSTED PROPERLY Figure 20 Figure 21 To turn the Zone Alarm off, press CLEAR, SHALLOWSET or DEEP SET or press CLEAR, uparrow or downarrow. All of the ZoneAlarm settingswill remain in memory. Pressing either SHALLOWor DEEPSET keys will turn theZone Alarn back on with the previoussettings. Discriminationmaybeturned off bypressing 0, DISC orCLEAR, DISC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE X-5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE X-5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.