User manual LOWRANCE X-38

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOWRANCE X-38. We hope that this LOWRANCE X-38 user guide will be useful to you.


LOWRANCE X-38 : Download the complete user guide (324 Ko)

Manual abstract: user guide LOWRANCE X-38

Detailed instructions for use are in the User's Guide.

[. . . ] X-28, X-38, and X-48 INSTALLATION AND OPERATION INSTALLA ALLATION OPERATION INSTRUCTIONS INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION -Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In other words, you can set the upper limit to 25 feet and the lower limit to 35 feet, regardless of the bottom depth. You can choose any segment of the water, as long as the distance between the upper limit and lower limit is 10 feet (10 meters) or more. To change the upper limit, first make certain the unit is in the manual mode. Next, press a menu key until the "UPPER LIMIT" menu appears. Now press the down arrow key to increase the upper limit or the up arrow key to decrease it. After you've finished, wait a few seconds and the menu will scroll off the screen's left side. Pressing the PWR key also clears it. 21 FOOT UPPER LIMIT To change the lower limit, again make certain the unit is in the manual mode. Now press the down arrow key to increase the lower limit or the up arrow key to decrease it. When you have the limit set, wait a few seconds and the menu will scroll off the screen's left side. Pressing the PWR/CLEAR key also clears it. 20 SENSITIVITY The sensitivity menu lets you control the unit's ability to pick up echoes. A low sensitivity level excludes much of the bottom information, fish signals, and other detail. High sensitivity settings lets you see features, but it can also clutter the screen with noise and other unwanted signals. Typically, the best sensitivity level shows a good, solid bottom signal with grayline. This sonar unit adjusts the sensitivity level to keep a solid bottom signal on the screen. However, situations occur where it becomes necessary to increase or decrease the sensitivity level. Typically, this occurs when you wish to see more detail, so you need to increase the sensitivity. The procedure to adjust it is the same whether the unit is in the automatic or manual mode. To change the sensitivity level, first press the menu key until the sensitivity menu appears. If the unit is in automatic, the menu shows "AUTO SENS. " Otherwise, the menu shows "MAN SENS. " Now press the up arrow key to increase the sensitivity, the down arrow to decrease it. Echoes scrolling onto the screen will also show the effects of the sensitivity change. If you reach the maximum or minimum sensitivity level, a tone sounds alerting you to the limits. After you've adjusted the unit to the desired sensitivity level, press the PWR key to clear the display. [. . . ] A technician may be able to solve the problem and save you the inconvenience of returning your unit. You will be asked for your unit's serial number. 800-324-1356 Canada Only. Central Time. How to Obtain Service (International Customers Only) If you need service or repairs, contact the dealer in the country you purchased your unit. WARRANTY REPAIR WILL BE HONORED ONLY IN THE COUNTRY UNIT WAS PURCHASED. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE X-38




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE X-38 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.