User manual LOWRANCE LMS-332C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOWRANCE LMS-332C. We hope that this LOWRANCE LMS-332C user guide will be useful to you.


LOWRANCE LMS-332C : Download the complete user guide (5848 Ko)

You may also download the following manuals related to this product:

   LOWRANCE LMS-332C (5752 ko)

Manual abstract: user guide LOWRANCE LMS-332C

Detailed instructions for use are in the User's Guide.

[. . . ] 988-0156-071 www. lowrance. com LMS-332C & LMS-337C DF Fish-finding Sonar & Mapping GPS Installation and Operation Instructions Copyright © 2004 Lowrance Electronics, Inc. No part of this manual may be copied, reproduced, republished, transmitted or distributed for any purpose, without prior written consent of Lowrance Electronics. Any unauthorized commercial distribution of this manual is strictly prohibited. Lowrance is a registered trademark of Lowrance Electronics, Inc. Navionics is a registered trademark of Navionics, Inc. eXitSource Database, copyright 2001-2004 Zenrin Co. [. . . ] A low sensitivity level (from zero to 50 percent) excludes much of the bottom information, fish signals, and other target information. High sensitivity levels let you see this detail, but it can also clutter the screen with many undesired signals. Typically, the best sensitivity level shows a good solid bottom signal with Colorline and some surface clutter. When the unit is in the automatic mode, sensitivity is automatically adjusted to keep a solid bottom signal displayed, plus a little more power. However, situations occur when it becomes necessary to increase or decrease the sensitivity. This typically happens when you wish to see more detail, so an increase in sensitivity is indicated. Or, wave action and boat wakes can create enough tiny air bubbles to clutter much of the water column. In that case, a decrease in sensitivity is indicated to reduce some of the clutter. The control bar used to adjust sensitivity up or down is the same whether the unit is in the automatic or manual mode. In automatic you can adjust sensitivity up to 100 percent but the unit will limit your minimum setting. In auto, the unit will continue to make small adjustments, allowing for the setting you selected. In manual mode, you have complete control over sensitivity, with the ability to set it anywhere from zero to 100 percent. Once you select a level in manual, the unit will continue to use that exact sensitivity setting until you change it or revert to auto mode. (When you reach the maximum or minimum limit, a tone sounds. ) At left, Sonar Menu with Sensitivity command selected. At right, the Sensitivity Control Bar. To adjust sensitivity in manual mode: 1. First, turn off Auto Sensitivity: from the Sonar Page, press MENU| to AUTO SENSITIVITY|ENT. To turn Auto Sensitivity back on: From the Sonar Page, press MENU| to AUTO SENSITIVITY|ENT|EXIT. NOTE: To return to the original factory setting for Auto Sensitivity, see the entry in this section on Reset Options. If sensitivity is in manual mode, the Reset Options command will switch back to Auto and reset the factory setting at the same time. Tip: For quicker sensitivity adjustments, try leaving the Sensitivity Control Bar on the screen as the chart scrolls. You can see the changes on the screen as you press the up or down arrows. This is handy when there's a lot of clutter in the water, and you are matching the sensitivity to rapidly changing water conditions. 85 Sonar Chart Mode The default color scheme for the sonar chart is the white background, but we offer other variations to suit your viewing preferences. [. . . ] If you're in the United States and you have technical, return or repair questions, please contact the Factory Customer Service Department. Before any product can be returned, you must call customer service to determine if a return is necessary. Many times, customer service can resolve your problem over the phone without sending your product to the factory. To call us, use the following toll-free number: 800-324-1356 8 a. m. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE LMS-332C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE LMS-332C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.