User manual LOWRANCE LCX-104C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOWRANCE LCX-104C. We hope that this LOWRANCE LCX-104C user guide will be useful to you.


LOWRANCE LCX-104C : Download the complete user guide (15616 Ko)

Manual abstract: user guide LOWRANCE LCX-104C

Detailed instructions for use are in the User's Guide.

[. . . ] 988-0151-031 www. lowrance. com Fish-finding Sonar & Mapping GPS LCX-104C Operation Instructions Copyright © 2002 Lowrance Electronics, Inc. Navionics is a registered trademark of Navionics, Inc. Points of Interest Data in this unit are by infoUSA, copyright 2001-2002, All Rights Reserved. infoUSA is a trademark of infoUSA, Inc. eXitSource Database, copyright 2001-2002 Zenrin Co. Ltd. Lowrance Electronics may find it necessary to change or end our policies, regulations and special offers at any time. [. . . ] You can select the chart to be displayed in grayscale, reverse grayscale, blue background, or bottom color tracking. Press EXIT|EXIT to return to the Sonar Page. Sonar Page & Sonar Chart Display Options The Pages Menu offers five chart display options for units with dualfrequency transducers and four options for units with single-frequency transducers. To access them, press PAGES| or to SONAR| to Option Name|EXIT. FlashGraf Pages Menu, showing sonar chart display options. Full Sonar Chart This is the default mode used when the unit is turned on for the first time or when it's reset to the factory defaults. Depth scales on the right side of the screen aid in determining the depth of targets. The bottom depth and surface temperature (if equipped with a temperature sensor or a transducer with a temp sensor built in) show at the top left corner of the screen. This changes all echoes into short horizontal bars, replicating a flasher sonar. The zoom bar on the far right shows the area that's zoomed when the zoom is in use. (See the Zoom section for more information. ) 75 Full Sonar Chart. The Overlay Data (depth and water temperature) are each set to a different text size. Split Zoom Sonar Chart A split chart shows the underwater world from the surface to the bottom on the right side of the screen. The zoom range shows at the bottom left corner of the screen. Split Zoom Sonar Chart. The depth overlay data is set to the default large text size; the water temperature is set to the small text size. Split Frequency Sonar Chart (Dual-Frequency Transducers only) This page shows sonar data from the 50 kHz transducer element on the left side of the screen and data from the 200 kHz transducer on the right side. 76 Split Frequency Sonar Chart page, with 50 kHz view at left and 200 kHz view at right. You can adjust the sensitivity in each window. (When you reach the maximum or minimum limit, a tone sounds. ) The Split Frequency Sonar Chart page allows you to adjust sensitivity separately for each window. 77 Digital Data/Chart This mode shows the chart on the right side of the screen. The left side has seven large digital boxes or windows containing: Water Depth; Water Speed (from an optional speed sensor); Water Distance (distance traveled or logged, it also requires a speed sensor); Surface Water Temperature; Temperature #2 and #3 and the unit's Voltage. (Note: Temperature #2 requires an additional optional temperature sensor. ) It also shows your current settings for the shallow and deep alarms. Digital Data/Chart Customizing the Digital Data/Chart Screen The Digital Data/Chart screen can be customized to show digital data different from the defaults first shown. From the Sonar Page (in Digital Data mode), press MENU| to CUSTOMIZE|ENT. The Customize command on the Sonar Page menu. 78 2. The Water Speed window title bar flashes, indicating the window contents can be changed. Press ENT| or to select data type|ENT|EXIT. Options List for customizing Digital Data windows. At right, Maximum Speed has been picked to replace Water Speed in the top digital data window. Tip: You can customize other digital data windows before returning to the Sonar Page. After changing the first window by selecting the Data Type and pressing Enter, use the key to select another window to change. When the selected window title bar flashes, press ENT| or to select data type|ENT. Repeat these steps until you're finished customizing, then press EXIT to return to the Sonar Page. [. . . ] This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. REMINDER: You must retain the sales slip or sales receipt proving the date of your original purchase in case warranty service is ever required. LOWRANCE ELECTRONICS 12000 E. SKELLY DRIVE, TULSA, OK 74128 (800) 324-1356 189 How to Obtain Service. . . . . . in the USA: We back your investment in quality products with quick, expert service and genuine Lowrance parts. If you're in the United States and you have technical, return or repair questions, please contact the Factory Customer Service Department. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOWRANCE LCX-104C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOWRANCE LCX-104C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.