User manual LOOK SOLUTIONS UNIQUE 2 HAZER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LOOK SOLUTIONS UNIQUE 2 HAZER. We hope that this LOOK SOLUTIONS UNIQUE 2 HAZER user guide will be useful to you.


LOOK SOLUTIONS UNIQUE 2 HAZER : Download the complete user guide (122 Ko)

Manual abstract: user guide LOOK SOLUTIONS UNIQUE 2 HAZER

Detailed instructions for use are in the User's Guide.

[. . . ] Operating manual 1 a Look Solutions product Set of Equipment supplied ­ ­ ­ ­ 1 Unique2 1 tank lid with quick connector, silicon tube and air valve filter 1 canister of UNIQUE-fluid, 2l 1 manual As an option: XLR remote for analogue control (delivered without cable) Diverter Case Hanging set Please check whether all the products you ordered are supplied. ­ ­ ­ ­ 2 Contents 1. Fluid 4. 1 General notes 4. 2 Changing the fluid canister 4. 3 Storage of the fluid 5. Operating the Unique2 5. 1 Selecting the location 5. 2 Putting into operation 5. 3 Switching the device off 5. 4 Control choices 5. 4. 1 Control via DMX 512 5. 4. 1. 1 Adjusting the DMX start address 5. 4. 1. 2 Adjusting the pump and the fan 5. 4. 2 Control via 0 - 10 Volt (+) DC 5. 4. 2. 1 Adjusting the pump and the fan 5. 4. 3 Stand alone mode 5. 4. 3. 1 Adjusting the pump and the fan 5. 4. 4 Control via Haze-Density Control System (HDCS) 5. 4. 4. 1 Using the Profile 5. 4. 5 Working with the internal Timer 5. 4. 5. 1 Autostart 5. 5 Wiring of the sockets 6. Introduction The haze machine Unique2 offers various new features, which open new fields of operation to the user. [. . . ] 5: Switching the device off You may control the Unique2 externally through the XLR sockets [2 and 3]. That means: when the machine is controlled via DMX 512 this data takes priority over 0-10V (+) DC and Stand alone operation. Please note: You can`t hold down the Mode-button for scrolling through the Menu. If the Mode-button is pressed more than two Seconds, the machine will change into the Timer-Mode (see point 5. 4. 5). The pump and the fan can be easily and separately adjusted and regulated in 99 steps via buttons. Any desired effect can be achieved in steps of 1%: from the finest mist to a thick haze, similar to fog. To achieve the thickest effect the pump must run at 99%, the fan at 1%. The finest haze can be achieved with lower pump and higher fan settings. The data can be readjusted whenever you want to. 5. 4. 1 Operating via DMX 512 Connecting the Unique2 to a DMX desk, use the XLR socket [2] beside the control panel. As soon as the machine receives a correct DMX signal, the yellow DMXLED [19] will be lit. First Channel = Pump, second Channel =Fan 5. 4. 1. 1 Adjusting the DMX start address a) Press the Mode-button [14] at the control panel until three figures appear on the LED-display [17] (see Fig. Operating the Unique2 b) Adjust the required start address by pressing the Up- or Down-button [15]. The start address will now also be saved when you disconnect the machine from the mains supply. 5. 4. 1. 2 Adjusting the pump and fan output If you run the machine via a DMX desk you can adjust the pump and the fan directly from the desk from 1 to 99%. The adjusted channel controls the pump, the following one controls the fan. 5. 4. 2 0 - 10 Volt (+) DC control Connect the Unique2 to an analogue desk or the cable remote which you can get as an option, using the XLR socket at the back of the machine [3]. Please note: With analogue control the pump can be adjusted from the desk and/or the cable remote. a) Put the cable from the desk or the cable remote into the XLR socket at the back of the machine [3]. b) Put the pump up to 99% and adjust the required fan output at the machine (see chapter 4. 4. 2. 1). c) With the turnable button on the cable remote or with the fader on the analogue desk the pump output can be regulated. d) Pressing the On/Off switch at the cable remote starts the haze process. The green Active-LED [18] will be lit. 5. 4. 2. 1 Adjusting the pump and fan output a) Press the Mode-button [14] at the control panel until a P and two figures appear on the LED display [17] (see Fig. b) Press the Mode-button [14] at the control panel until an F and two figures appear on the LED display [17] (see Fig. For example: The machine shall start to run after 30 Minutes (setting 1). [. . . ] ­ PLEASE NOTE: The vaporizer of our machines does not have to be cleaned!Troubleshooting Trouble: Cause: The pump runs, but little or no haze is produced. · Check whether the canister is empty · Check whether the brass collar is properly connected with the brass coupling · Check whether the fluid filter in the canister is clogged · Check whether the fluid tube is twisted or defective The yellow LED at the machine does not light up (only when running via DMX) Connection from the machine to the desk is faulty. · Check whether the plug is plugged in correctly · Check whether the cable is defective · Check whether the DMX start address is adjusted correctly During operation the Unique2 fails to work for a long time The overtemperature protection device is activated. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LOOK SOLUTIONS UNIQUE 2 HAZER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LOOK SOLUTIONS UNIQUE 2 HAZER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.