User manual LIFT-MASTER TCR1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER TCR1. We hope that this LIFT-MASTER TCR1 user guide will be useful to you.


LIFT-MASTER TCR1 : Download the complete user guide (105 Ko)

Manual abstract: user guide LIFT-MASTER TCR1

Detailed instructions for use are in the User's Guide.

[. . . ] TriCodeTM TCR1 Single Channel Receiver SPECIFICATIONS Output Rating: 5 Amps 28VAC or DC Max. Power: 12VDC or 18 to 34VAC/DC, @ 30ma RF Frequency: 300 or 310MHz Accessory Transmitters: TC1, TC2 and TC4 U. S. Patent Pending This device complies with FCC Rules Part 15 and IC Canada Rules and Regulations. [. . . ] Do not allow children to operate the door control push button or the remote control transmitters. Install the receiver (and all door control push buttons) out of the reach of children and away from all moving parts of the door and door hardware, but where the door/gate is visible. TABLE OF CONTENTS DESCRIPTION PAGE Setting Power Supply Selection. . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setting Output Relay Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Setting the Configuration Switch. . . . . . . . . . . . . . . . . . . . . . . . . 3 Setting DIP Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Disconnect power to opener before installing receiver or removing/replacing receiver cover. POWER SWITCH SETTINGS CAUTION:To avoid possibility of duplicating codes in adjacent systems, all transmitters and receivers should be re-coded prior to operation. Unless using maximum number of codes the following four codes should not be used: · All DIP Switches ON · All DIP Switches OFF · DIP Switches alternating ON/OFF · DIP Switches alternating OFF/ON. Step 1 Power Supply Selection Setting The Tri-codeTM receiver is factory set for 24 volt power input if 12 volt is required. Set jumper to the 12 volt setting (Refer to figure 1). Receivers should be installed at least 5 feet apart to avoid cross-talk. After completing installation, operate transmitter outside of building to make certain the chosen DIP switch setting does not operate with nearby garage door operators and/or security systems. If so, select another DIP switch setting and check the coded signal again. Repeat as necessary. RECEIVER MOUNTING Mount receiver to wall using #6 hardware (Not Supplied). (Refer to figure 1 for receiver mounting hole locations). BACK VIEW FIGURE 1 MOUNTING HOLES 2 OUTPUT RELAYS, CONFIGURATION & DIP SWITCH SETTINGS Step 2 Setting Output Relay Mode The TriCodeTM receiver is factory set for momentary relay output "MNT". (a) Momentary mode: The output relay will be on for . 5 seconds before turning off. (b) Constant pressure mode: Output relay is continuously on while receiving matching/valid ID code from transmitter. The output relay will turn off immediately once receiver does not receive a matching/valid ID code from the transmitter (Refer to figure 4). NOTE: If constant pressure mode is desired, open front cover and move mode jumper from "MNT" to "CST" (Refer to figure 2). Step 3 Setting the Configuration Switch The TriCodeTM receiver is factory set for Linear/Delta3TM. Locate the configuration switch and set it to the desired RF mode of operation (Refer to figures 2 and 4). [. . . ] TM Multi TM: works with all "Multi-Code " transmitters transmitted at 300 MHz using 10-bits ID system. TM StanleyTM: works with all "Stanley radio" transmitters transmitted at 310 MHz using 10-bits ID system. TM FIGURE 3 FRONT VIEW FIGURE 4 3 POWER CONNECTIONS Step 5 Power Supply Connections The receiver is connected to the opener via external screw terminals labeled 1, 2 and 3 (Refer to figure 5). FIGURE 5 TERMINAL 1 = COMMON TERMINAL 2 = OUTPUT RELAY TERMINAL 3 = POWER INPUT If the three terminals allign with three matching terminals on the operator, use the piggyback clips for screw to screw attachment. If spacing is different or not marked, use the wiring diagram in Figure 5. 01-16700C © 2000, The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER TCR1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER TCR1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.