User manual LIFT-MASTER TAC2C INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER TAC2C. We hope that this LIFT-MASTER TAC2C user guide will be useful to you.


LIFT-MASTER TAC2C INSTALLATION: Download the complete user guide (406 Ko)

You may also download the following manuals related to this product:

   LIFT-MASTER TAC2C PROGRAMMING GUIDE (168 ko)

Manual abstract: user guide LIFT-MASTER TAC2CINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Guide IMPORTANT: The TAC2C has a Ringer Equivalence Number (REN) of 5 with a TELCO line and a REN of 3 without a TELCO line. TAC2C TAC1 RETROFIT KIT FOR CROWN JEWEL SYSTEMS Introduction DO NOT run data wires and HIGH VOLTAGE wires in the same conduit. The HIGH VOLTAGE wires may interfere with the data wires and cause the unit to malfunction. [. . . ] RELAY 2, NO 2 Remove the screws from the Crown Jewel faceplate using the provided hex tool. Ground Wire POWER AUTOCALL PHONE/TELCO EXTERNAL KEYPAD RELAY 2 (no longer available) RELAY 1 EXIT (no longer available) SPECIFICATIONS Power Supply: 12 Vac 20 VA The 110 Vac outlet must be dedicated to the unit only. This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems: · Other equipment cannot introduce spikes, noise, surges, or dips into the power circuit. · The unit's operation will not be affected if any other equipment develops a short circuit across the power line. Dimensions: 9. 72" x 6. 22" (W x H) 9. 72" RELAY 2, NC RELAY 2, COM RELAY 1, NO RELAY 1, NC RELAY 1, COM CROWN JEWEL BOARD 3 Slide the faceplate forward and rotate downward. COLOR LABEL POWER AUTOCALL PHONE/TELCO RELAY 2, NO RELAY 2, NC RELAY 2, COM DESCRIPTION 12 volt AC power input Input for accessory device to trigger home dialing Input connection for TELCO NO input for Relay 2 NC input for Relay 2 COM input for Relay 2 NO input for Relay 1 NC input for Relay 1 COM input for Relay 1 5 Remove the screws (2) securing the faceplate to the housing. Microphone 1 2 5 8 0 3 6 9 # 6. 22" 4 7 Call Button RELAY 1, NO RELAY 1, NC RELAY 1, COM * Speaker Keypad 6 Attach the labeled wires to the new TAC2C board as shown. Crimp the ground lug onto the end of the ground wire on the new board. Ground Wire Rewire the relay 1 and 2 wires to the relay 1 and 2 terminal blocks on the new board. Testing TEST GATE / DOOR RELAYS Test Relay 1 RELAY 2 COM Ground Screw in existing housing RELAY 1 NC 1 Enter 4 digit Master Code. 2 Press 1 to test Relay 1. Remove the PHONE, POWER, and AUTOCALL terminal blocks from the new board. Leave the Relay 1 and 2 terminal blocks. Ground Lug RELAY 1 NO RELAY 1 COM RELAY 2 NO RELAY 2 NC Test Relay 2 POWER NO COM NC NO COM NC 1 Enter 4 digit Master Code. PHONE/TELCO RELAY 1 AUTOCALL RELAY 2 2 Press 2 to test Relay 2. RELAY 1 RELAY 2 PHONE/TELCO AUTOCALL POWER NEW TAC2C BOARD TEST THE TELEPHONE CONNECTIONS from the resident's telephone to 1 Place a telephone callproperly, then hang up the phone. verify the unit is operating 7 When wiring is complete, secure the new faceplate to the existing housing with the provided screws (4). 8 Connect the power wires to the new transformer and plug the transformer into a 110 Vac outlet ONLY, any other type of outlet will cause damage to the unit. 9 SET THE MASTER CODE 2 Press the "Call" button on the unit's keypad. The telephone in the residence should ring. 1 have someone answer 3 To test Relay9) to activate Relay 1. Thethe telephone and enter "*9" (Star + unit will disconnect the call as soon as the relay is activated. [. . . ] The Master Code should not be distributed as a User Code. 2 5 8 0 3 6 9 # 110 Vac Outlet ONLY 1 Enter on the unit's keypad. * 2 Enter 4-digit Master Code. Example: 1234. For complete programming information refer to the Programming Guide. IMPORTANT NOTE: DO NOT use the existing transformer, the provided transformer MUST be used instead. 01-35895 3 "BEEP" "BEEP" Write down the Master Code and store in a secure location. © 2010, The Chamberlain Group All Rights Reserved [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER TAC2C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER TAC2C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.