User manual LIFT-MASTER SW2200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER SW2200. We hope that this LIFT-MASTER SW2200 user guide will be useful to you.


LIFT-MASTER SW2200 : Download the complete user guide (129 Ko)

Manual abstract: user guide LIFT-MASTER SW2200

Detailed instructions for use are in the User's Guide.

[. . . ] You may or may not want different settings than those already defined. Doc 01-16169 Rev B LiftMaster 3 SLMAX/SW2200 Programming Controls Programming occurs on a 5-button, 2-LED membrane switch located on top of the control box (see Figure 1). Programming instructions appear on a 2-row, 16-character LCD screen. The OPEN LIMIT LED flashes during Open Limit programming. LCD SCREEN Sentexsystems Sentex Press the ENTER button to select a program or save program settings. Use the MENU Buttons to scroll up/down the programming menu. 0 1 -1 6 16 9F2 The CLOSE LIMIT LED flashes during Close Limit programming. Use the SETTINGS buttons to set the program settings. Figure 1: Programming Controls Viewing the Gate's Current Status The system's default screen displays the gate's current status. Refer to Figure 2. Sentexsystems Sentex Gate Type: SINGLE or MASTER/SLAVE Microprocessor Revision Gate Power: AC or UPS AC SINGL 3. 0 CLOSED 0 1 -1 6 1 6 9 F3 Gate Status: OPEN or CLOSED Figure 2: Status Screen Doc 01-16169 Rev B 4 SLMAX/SW2200 Programming Instructions Programming the Single Button Functions FACTORY DEFAULT: OPENING = STOP, NO TIMER RESET CLOSING = (None--button has no effect) MID-STOP = MID-STOP OPEN The Single Button (connected at the J8 input connector) programming feature allows you to configure the single button function (i. e. , how the gate reacts after you press the single button). [. . . ] Also, to stop the gate while setting the limits, release the (+) or (-) buttons. To set the Gate Open/Close Limits, follow these steps: PROCEDURES 1 Pressing the MENU buttons (!"), locate the LIMITS MENU option and press ENTER. 2 3 4 5 At the RESET LIMITS (+) prompt, press (+) to start programming. When the gate reaches the desired closed limit position, release (+) or (-) and press ENTER. The Close Limit LED will blink to indicate that the close limit position is accepted but not yet stored in the memory. When the gate reaches the desired open limit position, release (+) and (-) and press ENTER. The Open Limit LED will blink to indicate that the open limit position is accepted but not yet stored in the memory. The gate will automatically close, open, and finally close to the programmed close/open limit positions. When the operator finishes the test, the Close Limit and Open Limit LEDs will stay lit to indicate that the limit positions are now stored in the system's memory. DISPLAY PROMPT LIMITS MENU ENTER TO CHANGE RESET LIMITS (+) (+) TO CONTINUE (­) TO EXIT SET CLOSE LIMIT (+/­) TO POSITION SET CLOSE LIMIT ENTER TO SET 6 7 SET OPEN LIMIT (+/­) TO POSITION SET OPEN LIMIT ENTER TO SET 8 PRESS ENTER TO TEST LIMITS 9 Doc 01-16169 Rev B LiftMaster 7 Setting the Gate Operator Speed This feature allows you to change the speed of the gate. Please note that max speed (normal gate speed) and min speed (decelerated gate speed) have their own minimum and maximum range. For the SW2200, Table 4 provides speed settings based on the total amount of time it takes the gate to fully open or close. Refer to Table 3 and Table 4 to select proper gate speeds for the SLMAX and SW2200: MAX GATE SPEED (INCHES/SEC) 12" 11" 10" 9" 8" 7" 6. 8" MIN GATE SPEED (INCHES/SEC) 8. 8" 8" 7" 6" 5" 4. 2 --- PROGRAMMED SETTING 170 157 144 130 117 104 100 (Min. ) PROGRAMMED SETTING 120 (Max. ) 110 97 83 70 60 (Min. ) --- Table 3: Max and Min Gate Speeds for the SLMAX GATE OPEN OR CLOSE TIME (SEC) 14 15 16 17 18 19 20 21 22 23 24 25 PROGRAMMED SETTING 220 (Max. ) 200 190 170 155 145 130 120 115 110 105 100 (Min. ) Table 4: Max Gate Speed for the SW2200 Doc 01-16169 Rev B 8 SLMAX/SW2200 Programming Instructions NOTE: The open/close time settings in Table 4 are valid if: (1) You install the gate with the gate dimensions recommended in the installation manual. -and(2) The Open and Close Deceleration Limits are programmed at the minimum (100) setting. -and(3) The Min Gate Speed is programmed to 120. Factory Defaults SLMAX = MAX SPEED: 220 MIN SPEED: 60 = MAX SPEED: 220 MIN SPEED: 60 SW2200 Setting the Gate Speed To set the operator speed, follow the steps below: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the OPERATOR SPEED option and press ENTER. NOTE: Maximum speed refers to the speed of the gate during opening or closing. NOTE: Minimum speed refers to the speed of the gate when it slows down prior to reaching the open or close limit. MIN SPEED: (See Table) (+/­) TO ADJUST DISPLAY PROMPT OPERATOR SPEED MAX SPEED: (See Table) (+/­) TO ADJUST Doc 01-16169 Rev B LiftMaster 9 Setting the Deceleration Limits This feature allows you to set the distance during which the gate starts to slow down prior to stopping at the open or close limit. Set the Open Deceleration Limit FACTORY DEFAULT = MEDIUM To set the Open Deceleration Limit, follow these steps: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the OPEN DECEL LIMIT option and press ENTER. DISPLAY PROMPT OPEN DECEL LIMIT __ __ __ I __ __ __ [LESS 3 Press ENTER to save. MORE Set the Close Deceleration Limit FACTORY DEFAULT = MEDIUM To set the Close Deceleration Limit, follow these steps: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the CLOSE DECEL LIMIT option and press ENTER. [. . . ] To enable or disable the operator warning, follow the steps below: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the OPERATOR WARNING option and press ENTER. DISPLAY PROMPT OPERATOR WARNING OPERATOR WARNING DELAY START: (0-9) Setting the Gate's Timer to Close FACTORY DEFAULT = OFF This feature allows you to set the time (in seconds) the gate stays open prior to closing automatically. To set the gate's Timer to Close, follow these steps: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the TIMER TO CLOSE option and press ENTER. Press (­) or (+) to enable or disable the timer to close function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SW2200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SW2200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.