User manual LIFT-MASTER SL3000UL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER SL3000UL. We hope that this LIFT-MASTER SL3000UL user guide will be useful to you.


LIFT-MASTER SL3000UL : Download the complete user guide (13515 Ko)

Manual abstract: user guide LIFT-MASTER SL3000UL

Detailed instructions for use are in the User's Guide.

[. . . ] ® TM Instruction Manual SL3000ULTM SERIES H I G H T R A F F I C C O M M E R C I A L G AT E O P E R AT O R UL325 UL991 compliant compliant LISTED installation instructions and manual book for architects, general contractors and dealers © 2005 the chamberlain group, inc. ­ all rights reserved S L 3 0 0 0 U LTM Overview Limit Switch Box Pg. 20 Motor Capacitor Motor Interlock Assembly Drive Belt EMERGENCY RELEASE Pg. 28 Optional Factory Installed DC2000 Battery Back-Up Motor Models DC and DCH Only Radio Receiver Pg. 27 Gear Reducer Cover Built-In Reset Button Pg. 24 EMERGENCY RELEASE Crank Tool Pg. 28 Crank Tool Housing Pg. 28 Radio Receiver Antenna Chassis Limit Switch Chain Sprocket Operator ON OFF Switch Control Box OFF ON Limit Switch Chain Drive Sprocket Optional Factory Installed Heater Models H and DCH Only Pg. 33 Idler Wheels Optional Factory Installed DC2000 Battery Back-Up Controller Models DC and DCH Only Pg. 30 ® W4 Optional Plug-In Loop Detectors Pg. 39 OmniControlTM Board Surge Suppressor Terminal Pg. 19 UL Alarm Pg. 25 DC2000 Harness Pg. 30 SL Power Wires Pg. 18 N IO AC V UT20eutrald 1 CAck e NGroun la B hit n W ree G TM LISTED 1 TABLE OF CONTENTS Safety Instructions Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Horizontal Slide Gate Systems UL Listings Warnings and Precautions 4 4 5 5 6-9 10 Installation Recommended Setup and Operator Specifications Gate Post Warning Mounting Required Warning Signs Types of Installation Connecting the Chain Concrete Pad and Gate Attachment Gate and Operator Mounting Distance Optional Post Mounting Plate How to Connect Power (110 V) Surge Suppressor Terminal Input Connections (Wiring Optional Equipment) Choosing Gate Movement Direction (Open Left or Right) Adjusting Gate Traveling Distance (Limit Switches) Two-Way Adjustable Reversing Sensor Adjustable Timer Master / Second Operators with Timer On Master / Second Operators with Timer Off Built-In Reset Button Remove Control Board Audio Alarm Solenoid/Maglock J3 Plug Connection Radio Receiver Programming 11 12 13 14 15 15 16 17 18 19 20 20 21 21 22 23 24 25 25 26 27 Table Of Contents EMERGENCY RELEASE Optional Emergency Release Please DO NOT Touch me!. . Unless you are an Authorized Service Technician! © 2005 The Chamberlain Group, Inc. All Rights Reserved. 28 29 For Technical Support: 1-800-528-2806 2 TABLE OF CONTENTS Optional Factory Installed Equipment Optional Factory Installed DC2000 Back-Up Connection. Models DC and DCH Only Wiring Optional Devices to DC2000 Wiring Optional Safety Devices to DC2000 Optional Factory Installed Heater. [. . . ] All other terminals will only open with a single push of a button. 8 7 Fire or Any Key Switch 19 CHOOSING GATE MOVEMENT DIRECTION Open to the Left Open to the Right Choosing Gate Movement Direction OU T IN OU T OPEN LEFT DC-BACKUP RADIO W4 GBA MS LINK SENSOR ALARM REVERSE SENSOR ALARM SENSOR OFF OPEN LEFT ON OPEN RIGHT OPEN EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR ADJUSTING GATE TRAVELING CLOSE STOP IN MER 60 MER 60 1 3 CENTER SAFETY EXIT 1 3 OFF ON OPEN RIGHT OFF OPEN LEFT ON OPEN RIGHT SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD RADIO 1 3 MADE IN USA 1 3 1 3 DISTANCE Adjusting Gate Traveling Distance Nut Push Plate Limit Nut Lock Plate Each notch is an estimated 1 inch of gate travel. Before Adjusting, Do the Following: 1. If you need more adjusting, repeat the process. 2-WAY ADJUSTABLE REVERSING SENSOR Adjusted by Qualified Service Personnel CENTER SAFETY EXIT 2-Way Adjustable Reversing Sensor DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE STOP SENSOR ALARM 3 1 3 MADE IN USA EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR DO NOT TOUCH ALARM SENSOR CAUTION: If the power supply to the gate operator is less than 99 volts, adjust the alarm by turning the alarm adjustment counter-clockwise enough to actuate the alarm when obstructed but not sensitive enough for false triggering to occur. The level of reverse sensitivity depends on the Minimum weight of the gate and the condition of Sensitivity installation. To make a better gate system, use any of Chamberlain Elite's power wheels. Not sensitive enough = if the gate hits a vehicle and does not stop or reverse. ADJUSTABLE TIMER TIMER NSOR CENTER SAFETY EXIT 60 3 REVERSE SENSOR Maximum Sensitivity Timer ON Set Timer 1 to 60 seconds Adjustable Timer OFF OPEN LEFT ON 1 3 OPEN RIGHT DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD SENSOR ALARM REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 TIMER NSOR OPEN EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT Timer can be set from 1 to 60 seconds (Timer ON), OR for push open/push close type operation (Timer OFF). Timer OFF Note: When using master/second gates, the gate that takes the longest to open should be set as the master. 21 MASTER/SECOND Master Omni Board Primary Control for System WITH TIMER ON Master and Second Boards are Interchangeable Caution: Never run high voltage and low voltage wires in same conduit Master / Second with Timer ON Use low voltage wires in separate conduit to connect gate operators together Note: The gate that takes the longest to open should be set as the master. CENTER SAFETY EXIT Master Omni Board TIMER SENSOR ALARM 60 3 NSOR DC-BACKUP OFF OPEN LEFT ON 1 3 Adjust Time Desired 0 to 60 seconds CENTER W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN OPEN RIGHT REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT Second Omni Board SAFETY EXIT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP ® OmniControl Surge Suppressor P/N Q410 Patent Pending Master Timer "ON" + DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT 1 3 1 3 ­ COMMAND PROCESSED Class 2 Supply 24 Volts DC EXIT M/S Link CENTER SAFETY G B A Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button Radio Receiver FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR ® OmniControl Surge Suppressor P/N Q410 Patent Pending ­ + Radio Receiver Class 2 Supply 24 Volts DC G B M/S Link A Use Shielded Twisted Wires to Connect the Surge Suppressor of each Gate Operator Together P/N Q410 Patent Pending Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button P/N Q410 Patent Pending G B M/S Link A Center Loop G B M/S Link A Center Loop MAXIMUM Counterclockwise Setting CHASSIS GROUND CHASSIS GROUND 1. Connect G from the master surge suppressor to G of the second surge suppressor. Connect B from the master surge suppressor to B of the second surge suppressor. Connect A from the master surge suppressor to A of the second surge suppressor. Use MASTER timer ONLY to select the desired time TIMER 60 3 NSOR OFF OPEN LEFT ON 1 3 OPEN RIGHT Second Timer "ON" 22 SENSOR ALARM MADE IN USA MASTER/SECOND WITH TIMER OFF Caution: Never run high voltage and low voltage wires in same conduit Use low voltage wires in separate conduit to connect gate operators together CENTER Master Omni Board SAFETY EXIT CENTER SAFETY Second Omni Board EXIT Master / Second with Timer OFF TIMER SENSOR ALARM DC-BACKUP 60 3 DC-BACKUP W4 GBA MS LINK W4 SYSTEM ON GBA TIMER 60 3 POWER OVERLOAD OPEN NSOR SENSORS REVERSE SENSOR REVERSE SENSOR ALARM SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT OFF OPEN LEFT ON OPEN RIGHT MADE IN USA OPEN OFF OPEN LEFT 1 3 MS LINK SENSORS SYSTEM ON TIMER 60 3 ON EXIT CENTER SAFETY POWER OVERLOAD 1 3 1 3 1 3 1 3 1 3 EXIT STOP COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED CLOSE EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OPEN RIGHT EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR ® OmniControl Surge Suppressor P/N Q410 Patent Pending ® OmniControl Surge Suppressor P/N Q410 Patent Pending ­ + Radio Receiver Class 2 Supply 24 Volts DC ­ + Radio Receiver Class 2 Supply 24 Volts DC G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button G B M/S Link A Center Loop Safety Loop Exit Loop Fire Dept Key Switch Strike Open Push Button Use Shielded Twisted Wires to Connect the Surge Suppressor of each Gate Operator Together P/N Q410 Patent Pending P/N Q410 Patent Pending G B M/S Link A Center Loop G B M/S Link A Center Loop TIMER NSOR 60 3 CHASSIS GROUND CHASSIS GROUND OFF OPEN LEFT 1 3 ON OPEN RIGHT 1. Connect G from the master surge suppressor to G of the second surge suppressor. Connect B from the master surge suppressor to B of the second surge suppressor. Connect A from the master surge suppressor to A of the second surge suppressor. Turn timers on BOTH Omni boards to the "OFF" position PARTIAL MASTER/INDIVIDUAL CONTROL In order for the following operation to occur, follow the instructions. Example: There is a double gate, the entry gate is to be opened with a radio transmitter and the exit gate with a free exit loop. Only one safety loop system is to open both gates, and a fire department switch should open both gates at the same time. (Observe polarity of both operators) 23 CLOSE STOP SENSOR ALARM MADE IN USA BUILT-IN RESET BUTTON Built-In Reset Button When the gate operator's audio alarm (See next page) has been tripped, the Reset Button must be pushed for the operator to function again. The Reset Button will shut off an activated audio alarm and reset the operator to function again. If the audio alarm goes off, always check the gate area for: · Obstructions in the gate path. · Damage to the gate and/or gate operator. Pressing the Reset Button will stop a moving gate during a normal open/close cycle, like a stop button. The operator does NOT need to be reset after doing this. 24 REMOVE CONTROL BOARD OFF OFF ON ON Remove Control Board W4 W4 Disconnect wire harnesses from OmniControl board. Unscrew 3 nuts and remove board. AUDIO ALARM When one of the following events happens Twice Consecutively, the Alarm will Sound for 5 minutes! Press the Built-In Reset Button to Shut Off Alarm and Reset Operator!(See previous page) 1 The gate is too heavy. Audio Alarm 2 Debris is on the gate's track such as mud, rocks, dirt, etc. 3 The gate is hitting a wall or vehicle. 4 The gate has one or more broken wheels. 5 A moving vehicle has hit the gate and the wheel is off the track. 25 SOLENOID/MAGLOCK J3 CONNECTION 2 4 CENTER SAFETY EXIT 1 3 5 7 9 J3 Normally Closed Common 6 8 10 SENSOR ALARM Solenoid / Maglock J3 Connection Normally Open Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit. Relay Contact Rating 0. 5 A - 125 Vac 1 A - 24 VDC DC-BACKUP W4 GBA MS LINK SENSORS SYSTEM ON TIMER 60 3 POWER OVERLOAD OPEN CLOSE STOP REVERSE SENSOR ALARM SENSOR 1 3 OFF OPEN LEFT ON OPEN RIGHT MADE IN USA 1 3 1 3 EXIT COMMAND PROCESSED CENTER SAFETY FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Solenoid Lock 2 4 6 8 10 1 3 5 7 9 #7 Common Solenoid Lock J3 #3 Normally Closed Ground Plug-In Transformer Wire Nut Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness) Power Ground Magnetic Lock Magnetic Lock 2 4 6 8 10 1 3 5 7 9 J3 Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) #7 Common Ground Plug-In Transformer Wire Nut Power Ground #8 Normally Open 26 RADIO RECEIVER PROGRAMMING Note: Hand Held Remote NOT Included with Gate Operator. Radio Receiver Programming Up to 31 Security Plus, Passport remotes or unlimited dip switch remotes can be used. Programming Radio Receiver: Press and Release the "Learn Button". Within that time, press a desired button on your hand held remote for 3 seconds to program the radio receiver. Repeat this process for every hand held remote to be used with the gate operator. Erase ALL Remote Control Codes: Press and Hold the "Learn Button" until LED turns off (6 seconds). All codes are now erased. Optional Hand Held Remotes Part # 971LM Part # CPT1 Part # 972LM Part # CPT2 Mini 3 Button Part # 970LM l ona Optiducts Pro Part # 973LM Part # CPT3 Mini 3 Button Part # CPTK3 Part # 974LM Part # CPT4 Mini 3 Button with HID Prox. [. . . ] Reset the motor Overload LED On and Power LED On System On LED Flashing 1. Alarm sensor is extra sensitive Troubleshooting Table Reverse Sensor LED On 1. Turn the reverse sensor switch counter clockwise a little more and try again 1. Turn the alarm sensor switch counter clockwise a little more and try again Alarm Sensor LED On Command Processed LED On 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL3000UL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SL3000UL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.