User manual LIFT-MASTER SJ

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER SJ. We hope that this LIFT-MASTER SJ user guide will be useful to you.


LIFT-MASTER SJ : Download the complete user guide (6872 Ko)

Manual abstract: user guide LIFT-MASTER SJ

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL MODEL SJ SPEED JACKSHAFT OPERATOR TH E CH EL AM MHU BE RS RL T, AIN IL LI GRO NO IS UP 60 , IN 12 C. 6 41 B6 PL AC E LI ST ED RA TIN G LA BE L DO OR HE RE OPE RA TO R NOT FOR RESIDENTIAL USE 2 YEAR WA R R A N T Y Serial # (located on electrical box cover) Installation Date Wiring Type SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Synchronous continuous duty ENCLOSURE:. . . . . . . . . . . . . . . . . . . . . . . ODP NEMA 56c face mount. HORSEPOWER: . . . . . . . . . . . . . . . . . . . 1 HP Single or Three phase SPEED: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 & 230 Single phase 230 & 460 Three phase 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER: . . . . . . . . . . . . . . . 1PH: 120/240 VAC 24VAC 3PH: 240/480 VAC 24VAC 3PH: 575 VAC 24VAC CONTROL STATION: . . . . . . . . NEMA 4 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . . . Standard C2 Wiring- Standard operators are shipped from the factory set for C2 wiring, which requires momentary contact to open, constant pressure to close, stop on reverse. [. . . ] IN ORDER TO KEEP NEMA-4 INTEGRITY, "LIQUIDTITE" CONDUIT CONNECTIONS MUST BE USED. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY. Recommended 7/8" Dia hole for limit conduit access CAUTION WARNING WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. W CAUTION Recommended 7/8" Dia hole for brake/electrical disconnect conduit access Recommended 7/8" Dia hole for motor conduit access TH E CH ELM A M HU BE RS RLA T, IL IN G LI NO RO IS UP 60 , IN 12 C 6. Recommended 7/8" Dia hole for power conduit access 41 B6 PL AC E LIS RA TIN G TE D LA BE L DO OR HE RE OP ER AT OR Recommended 7/8" Dia hole for photo eyes conduit access WARNING Do Not Run Power & Control Wiring in the Same Conduit Recommended 7/8" Dia hole for safety edge conduit access 5 CONTROL WIRING DETERMINE WIRING TYPE Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring. WIRING TYPES Standard C2 Wiring Standard operators are shipped from the factory set for C2 wiring, which requires momentary contact to open, constant pressure to close, stop on reverse. B2 Wiring Option Dip switch selectable, momentary contact to open, close and stop. Entrapment protection device must be included. SPECIAL CONTROL WIRING If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require additional instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections. IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact the customer service department @ 1-800-528-2806. LOCATING THE CONTROL STATION All operators are supplied with a three button station (OPEN/CLOSE/STOP) incorporated into the wall mounted starter. Mount the wall mounted starter where the door is visible, but not directly underneath the door, operator, or mounting hardware. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the wall mounted starter. WARNING INSTALL THE WALL MOUNTED STARTER WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF STARTER CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. W CAUTION TH E C EL HA MH MB UR ER ST LA , IL IN LI GR NO O IS UP, 60 IN 12 C 6. OPEN WARNING CLOSE 41 B6 LI PL AC E RA TIN G STE D LA BE L DO OR TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR HE RE OP ER ATO R WARNING Notice 6 CONTROL WIRING (con't) Radio Controls All radio controls must have dr y contact relay outputs. Do not take power from the components inside the electrical enclosure. WARNING DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. W CAUTION Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. Any control with a normally (N. O. ) isolated output contact may be connected in parallel with the OPEN button. 2) Terminal J2-19 and J2-20 will close when the door is stopped at any position other than fully closed. Single button control is available as an optional device and is wired to terminals J2-11 and J2-12 on the LMPLC board. POWER WIRING POWER WIRING CONNECTIONS 1. Connect power wires to the J1 terminal block located on the Printed Circuit Board (shown below). CONTROL STATION WIRING CONTROL WIRING CONNECTIONS 1. Connect control wires to the J2 terminal block located on the Printed Circuit Board (shown below). (See wiring diagram page 11, 13, and 15) (See wiring diagram page 11, 13 and 15) GROUND WIRING 1. Connect earth ground to chassis ground screw in the electrical box enclosure marked with the label shown below. 2. Press OPEN push button and observe direction of door travel and then Press the STOP button. [. . . ] Check wire connections for tightness and wire insulation for defects of abrasions. Check wires to safety edge, or infrared safety eyes, if unit is equipped with a safety to reverse feature. Generally inspect the motor mounting, and tighten the fasteners and bracing. Verify that all conduit connections are tight and have no exposed wires. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SJ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SJ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.