User manual LIFT-MASTER HJ

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER HJ. We hope that this LIFT-MASTER HJ user guide will be useful to you.


LIFT-MASTER HJ : Download the complete user guide (4078 Ko)

You may also download the following manuals related to this product:

   LIFT-MASTER HJ REPLACEMENT PARTS (1072 ko)

Manual abstract: user guide LIFT-MASTER HJ

Detailed instructions for use are in the User's Guide.

[. . . ] LO G IC OWNER'S MANUAL MODELS: L C O N TR O L FACTORY SET C2 Wiring J H HJ See pages 15 and 16 for other wiring configurations LOGIC CONTROL (VER. 2. 0) INDUSTRIAL DUTY DOOR OPERATOR PATENT PENDING The Maintenance Alert System TM allows the installer to set an internal Maintenance Cycle Counter. An LED on the 3-button station will signal when the set number of cycles is reached or when the opener requires immediate service. 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR Before attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. These instructions are intended to highlight certain safety related issues. [. . . ] The abbreviations are Open Limit Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch (SLS). Logic Control Pushbuttons Open, Close, Stop Open, Close and Stop buttons are mounted directly on the Logic Control board. This will provide easy programming ability and door control at the electrical box. Either the stop control or a jumper must be wired between terminals 4 and 5 for the on board push buttons to function. WIRING TYPE PROGRAM SETTINGS Determine wiring mode: There are many wiring modes available on the Logic Board. Read the descriptions of the different wiring types to determine which setting will be correct for each application. Set the dip switches to the desired wiring mode: Adjust the 4 dip switches on the logic board to match the settings for the desired wiring type. The dip switches are shown in the picture TYPE STATION C2 1 2 3 4 ON ON C2 3 Button, 3 Button Radio Control Function: Momentary contact to open and stop with constant pressure to close, open override plus wiring for sensing device to reverse. Programmable mid stop available with this wiring type. OFF ON ON B2 1 2 3 4 B2 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. Programmable mid stop available with this wiring type. OFF ON ON D1 1 2 3 4 D1 2 Button, 3 Button Radio Control Function: Constant pressure to open and close with wiring for sensing device to stop. OFF E2 3 Button Radio Control Function: Momentary contact to open with override and constant pressure to close. Release of close button will cause door to reverse (roll-back feature) plus wiring for sensing device to reverse. ON ON E2 1 2 3 4 OFF TS 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close, and stop with open override and Timer To Close. Every device that causes door to open, including a reversing device, activates the Timer To Close. Auxiliary controls can be connected to open input to activate the Timer To Close. If the timer has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the Timer To Close until the next command input. The Timer To Close will function from the programmable mid-stop with this wiring type. (NOTE: Requires Optional self monitoring photo eyes to operate. ) 15 ON ON TS 1 2 3 4 OFF WIRING TYPE PROGRAM SETTINGS CONT'D TYPE STATION T 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close, and stop, with open override and Timer To Close. Every device that causes the door to open, except a reversing device, activates the Timer To Close. Auxiliary controls can be connected to open input to activate the Timer To Close. If the Timer To Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer to Close will function from the programmable mid-stop with this wiring type. (NOTE: Requires Optional self monitoring photo eyes to operate. ) FSTS Momentary button contact for open, close and stop. [. . . ] If the Stop Button light is out, check the wiring to the control station, if the site does not require a stop button use a jumper across terminals 4 and 5. The LEDs should light with each Open, Close, and Single Button Control command. Also watch the LED's during door travel to check for over active limit switches. Disconnect all devices and reattach them one at a time testing for failure after each item is replaced. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER HJ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER HJ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.