User manual LIFT-MASTER GH LOGIC 4 QUICK START GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER GH LOGIC 4. We hope that this LIFT-MASTER GH LOGIC 4 user guide will be useful to you.


LIFT-MASTER GH LOGIC 4 QUICK START GUIDE: Download the complete user guide (787 Ko)

Manual abstract: user guide LIFT-MASTER GH LOGIC 4QUICK START GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] QuickStart Operator Mounting 1a Wall Mount: The operator should generally be installed below the door shaft, and as close to the door as possible. LOGIC 4 for the model GH door operator IMPORTANT: This QuickStart is intended to highlight a typical installation. Since each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information. Manual Operation 1a Right Hand Wall Mounted Operator 1b Bracket Shelf Mounted Operator This operator has provisions for manually operating the door in case of emergency or power failure. [. . . ] When in position, secure the operator to wall or mounting bracket. 7 Align sprockets, insert key into keyway, and secure. 9 Run the power wires through the power wiring conduit hole in the electrical box enclosure. Connect the earth ground to the ground screw in the electrical box enclosure. Follow ALL local electrical codes. Turn off power to the operator BEFORE manually operating your door. Electrical Interlock with Hoist 10 Adjust the limit switches to open and close door properly. Make sure the limit nuts are positioned between the limit switches before proceeding with adjustments. 11 Radio programming and troubleshooting instructions inside cover of operator. Inside the Electrical Box 9 Single Phase Connections HOT NEUTRAL EARTH 7 Align Sprockets Three Phase Connections 10 Limit Switches Retaining Plate SE L1 L2 Follow ALL national and local electrical codes. Power wiring ONLY! DEDICATED CIRCUIT CLO L1 L2 L3 Limit Nuts N OPE Be sure door sprocket is properly aligned with drive before securing to the shaft. Mount Chain Keeper 4' above floor Chain Keeper (with pad locking provisions) POWER WIRING USE COPPER WIRE ONLY POWER WIRING USE COPPER WIRE ONLY DEDICATED CIRCUIT SAF ETY Push Direction Limit Nut Will Move During Travel 14 AWG Minimum Chain Keeper (4' above floor) Board Selector Dial Factory Setting is C2 T E2 D1 TS FSTS DIAG OPTN PROG CONTROLWIRE ONLY WIRING 20 AWG or Greater USE COPPER 1 SBC 2 3 4 Common 5 Stop 6 Close 7 Open 8 Edge 9 10 11 12 13 14 LMEP 8 LiftMaster Monitored Entrapment Protection (LMEP) is required for most programmable settings. Thru-Beam Photoelectric Sensors (Shown) MAS 11 Common Timer Defeat 24VAC 11 9 24VAC White White/Black NEVER run Control wiring in same conduit as the Power wiring! C2 B2 Maintenance Alert LED 10 Follow ALL national and local electrical codes OPEN 7 6 5 4 4 4 Push and Release to Open (without Mid Stop programming) CLOSE STOP Push and Release to Stop MAS Programming (Maintenance Alert System) 1. The MAS assists the installing dealer in setting up a routine maintenance program. Once programmed, the MAS notifies the end user (with a flashing LED on the 3 button station) when a preset number of cycles/months has elapsed and scheduled maintenance is due. Press the STOP button once to Clear the MAS Setting. MAS OPEN CLOSE STOP D20 D21 Timer-to-Close Programming Timer automatically closes door after a preset time. Press and release the TIMER button. MRT MID C2 B2 T E2 D1 TS FSTS DIAG OPTN Approximately 5 Feet Push and Hold to Close 6" max above the floor Half the Height of the Door Edge Sensor D13 PROG OPEN D20 OPEN Mid Stop Programming The mid stop feature is to open the door to a preset point prior to the fully open position. Close the Door. E2 T D1 C2 B2 TS FSTS DIAG OPTN TIMER CLOSE D21 2. The CLOSE LED will flash once for every 3 months. MAS OPEN CLOSE STOP D20 STOP D13 4. [. . . ] Press the STOP button once to clear the MAS counter. D13 MID TIMER T E2 D1 TS FSTS DIAG CLOSE STOP D21 7. NOTE: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) device installed. © 2010, The Chamberlain Group Inc. Turn selector back to selected wiring type. C2 B2 OPTN PROG 01-35245 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER GH LOGIC 4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER GH LOGIC 4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.