User manual LIFT-MASTER EL2000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER EL2000. We hope that this LIFT-MASTER EL2000 user guide will be useful to you.


LIFT-MASTER EL2000 : Download the complete user guide (5266 Ko)

You may also download the following manuals related to this product:

   LIFT-MASTER EL2000 INSTALLATION V3.0 (4031 ko)

Manual abstract: user guide LIFT-MASTER EL2000

Detailed instructions for use are in the User's Guide.

[. . . ] Apply pressure to left-side until you hear a "click" sound 4. Apply pressure to right-side of unit until you hear a "click" sound ? 4 7 8 9 * 0 # 2 3 4 1 4 7 # * 2 #3?56 89 1 4 2 5 3 6 ? 7 8 9 1 4 2 5 3 6 ? # 0 # * # 0 # 7 8 9 * # 0 # # Page 4 EL2000 Installation NOTE: This unit is for surface and recessed mount ONLY. 1 Unlock Unit 2 Open Cover 1 2 5 3 6 ? 4 7 8 9 1 2 4 5 * 0 # # 3 6 ? 7 8 # * 9 0 # EL2000 Model Installation 4 3 Unplug the 2 Main Harnesses (Optional) Slide Front Cover Out of Hinges (Optional) 5 Knock-out Desired Mounting Plugs Using Punch Mount Back Housing to Wall or Pedestal 6 Page 5 Wire Connections to the Unit IO Output Board EXIT REQ 4 COM DOOR STAT 4 EXIT REQ 3 COM DOOR STAT 3 EXIT REQ 2 NO J5 4 J7 10 LED 4 NC C RELAY 4 NO RES 3 J6 POSTAL 5 6 7 J3 J6 8 J4 11 NC C LED 3 RELAY 3 NO Wire Connections to the Unit COM DOOR STAT 4 EXIT REQ 1 COM DOOR STAT 1 2 J5 AUTO J2 TELCO J1 POWER 12VAC/DC J3 12 NC C 9 J8 J1 1 J4 LED 2 NO RELAY 2 IO Input Board 13 NC C LED 1 RELAY 1 20-Pin to Main Board 14-Pin to Main Board Input Board Connections 1. Relay 1, NO, NC, COM NOTE: All relays are factory set to "Strike" and "10 sec. " DO NOT overload the removable terminal block connectors. [. . . ] Insulate this wire from the unit to prevent a short (Refer to instructions supplied with your Wiegand device for more information). J407 Position Device 4 Device 3 P12V COM P5V LED DATA 0 DATA 1 DATA 1 DATA 0 LED P5V COM P12V J400 Position Device 2 Device 1 P12V COM P5V LED DATA 0 DATA 1 DATA 1 DATA 0 LED P5V COM P12V Black Brown White Green Red Power Use 18-24 AWG Card Reader is Wired to Device 1 Blue (Insulate this wire). J2 J1 J2 J1 Shield (Attach to the unit ground only). 1 Wiegand Module Kit Part # WOMODKT Wiegand Modules will fit in J400 as Device 1 (J1) and 2 (J2) and/or J407 as Device 3 (J1) and 4 (J2) (4 Mounting Screws per Board are Required) Page 18 Wiring a Postal Lock Switch - EL25 Models Only The Post Office requires installation of a postal lock if postal carriers do not have access to a controlled area. Contact the local post office and arrange for them to install the postal lock while you are on site. The postal lock requires a switch to activate one of the four relays (Configurable with programming number 69 , in the Keypad Programming Manual). J7 Wiring a Postal Lock Switch / Internal Camera (CCTV) In J6 N. C. POSTAL J3 Common Use 18-24 AWG J5 AUTO J2 Switch J1 POWER 12VAC/DC J4 IO Input Board Input Board (See page 6) DO NOT overload the removable terminal block connectors. One wire per hole. NOTE: In the EL2000 models, the postal lock switch is pre-wired. Wiring an Internal Camera [CCTV] An Optional CCTV (Close Circuit Television) camera can be installed inside the unit. Refer to instructions supplied with the camera kit for more information. Contact your dealer/ installer for more information Home Entertainment System OR RG-59u Coaxial Cable 1000 Feet Maximum (Monitor with a . 25 volt p-p composite signal sensitivity) EL25 EL2000 A Closed Circuit Monitor Page 19 Wiring Power to the Unit The 110 VAC outlet must be dedicated to the unit ONLY. This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems: · Other equipment cannot introduce spikes, noise, surges or dips into the power circuit. · The system's operation will not be affected if any other equipment develops a short circuit across the power line. Connect the transformer into a 110 VAC outlet after all connections have been made. Any other type of outlet will cause damage to the system. Wiring Power to the Unit AC Power 12 VAC or 16 VDC EL Series Unit MUST be Properly Grounded!Bus 1, 2, 3 On Off Air (1) Conditioner On Off Off Rm 2, 3 On Off Conference Main Room On Off Conference Room 1 EL Model Conference Room 2 Off Eug. 2 Rm Dedicated 10 Amp Minimum Circuit J7 Input Board (See page 6) J6 POSTAL J3 J5 AUTO J2 Polarity Does Not Matter (See table on page 7 for AWG) J1 POWER 12VAC/DC J4 IO Input Board Page 20 Powering Up and Checking the LEDs 1 7 D300 H2 100A UD 2 3 4 J201 MIC 5 6 J403 J500 H2 100A UD J406 LCD J405 8 11 9 D102 J401 3D2 100 16B D2 Wiring Power and Powering Up Unit 12 J301 D153 3D2 100 16B 3D2 100 16B H2 100A UD 10 J404 3D2 100 16B J400 15 J300 BT300 SW300 OV UV D513 D514 J402 LEDJ200 SPKR 16 No. 1 2 3 4 13 17 18 Name Type LED Connector Connector Connector Board Label D300 J405 J500 J406 Used on Model EL25 EL2000 X X X X X X X 5 6 7 8 9 10 11 12 13 14 15 16 17 Connector Connector Connector LED LED LED Connector Connector Connector Connector Connector Connector Switch J201 J403 J401 D2 D102 D153 J301 J404 J407 J400 J300 BT300 SW300 X X X X X X X X X X X X X X X X X X X X X X X PWR LED 20-Pin Connector to IO Input Board LCD PWR EL25=LED BOTTOM KEYPAD EL2000=LED keypad MIC 14-Pin Connector to Output Board KEYPAD Local Mode RES DAA OFF HOOK TELCO DAA OFF HOOK Direct Connect (Serial Port) LED Power Supply Module Device (3, 4) Module Device (1, 2) LCD Data Battery OV/UV Reset X X 18 LED D513 X X Over-Voltage (OV) 19 LED D514 X X Under-Voltage (UV) 20 21 22 Connector Connector Switch J402 J200 SW500 X X X X X LED TOP KEYPAD Main Speaker Soft Reboot 3D2 100 16B + J407 DEVICE 3, 4 DEVICE 1, 2 19 20 21 22 14 Description Indicates Unit is receiving power Connector to IO Input Board. The IO Input Board contains all REX inputs, DSC inputs and Postal input, Auto Sensor input and Power. For the EL25 provides power to bottom lighted LEDs for the main keypad. Connector for the main keypad Unit supplying Central Office Power to Resident Resident side of circuit is off hook Telco side of circuit is off hook Used for direct connect and handheld programming and Real Time Monitoring. The device address becomes 3 (RF or Wiegand-J1) or 4 (Wiegand-J2) Connect a module (Wiegand or RF) device here. The device address becomes 1 (RF or Wiegand-J1) or 2 (Wiegand-J2) Data wires for LCD Display Battery used to back-up the Unit's real time clock. If a poor power condition still exists then the OV or UV LEDs may turn on again. Turns on when the Unit detects an over voltage of 16. 5 VAC or 22. 3 VDC at power block J1. Turns on when the Unit detects an under voltage of 9. 5 VAC or 10. 2 VDC at power block J1. Main Speaker Reboots firmware without removing power. Page 21 Troubleshooting Wiring · Check for correct length and AWG of wires. · Check that wires are correctly inserted into the terminal blocks (not loose, no two sharing the same position). [. . . ] In some cases, the company's inside wiring associated with single line individual service may be extended by means of a certified connector assemble (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER EL2000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER EL2000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.