User manual LIFESAVER LIF 3010 SMOKE ALARM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFESAVER LIF 3010 SMOKE ALARM. We hope that this LIFESAVER LIF 3010 SMOKE ALARM user guide will be useful to you.


LIFESAVER LIF 3010 SMOKE ALARM : Download the complete user guide (294 Ko)

Manual abstract: user guide LIFESAVER LIF 3010 SMOKE ALARM

Detailed instructions for use are in the User's Guide.

[. . . ] LIFESAVER MODEL LIF 3000 SMOKE ALARM LIF 3010 SMOKE ALARM IONISATION DESIGN USER MANUAL AUSTRALIAN ELECTRICAL AUTHORITY CS: 96262V IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLATION. NO USER REPLACEABLE PARTS INSIDE THIS SMOKE ALARM. Do not attempt to repair the smoke alarm yourself. SPECIFICATION ELECTRICAL RATING: 240VAC 50Hz, 80mA per alarm, interconnectable up to 24 alarms. WARNING: THIS SMOKE ALARM MUST ONLY BE WIRED TO A 240VAC 50Hz SINE WAVE CURRENT SUPPLY. [. . . ] 7. 5. 1 7. 5. 2 7. 5. 3 7. 5. 4 Test alarm by pushing and holding the test button for a few seconds. This should sound the alarm if all electronic circuitry and horn are working. If no alarm sounds, check wiring, fuses or circuit breaker and make certain that alarm is connected to a continuous final sub-circuit. With interconnected units, activating the test button on one unit will cause all connected units to sound. Continuous chirping or erratic noise or low sound from an alarm may indicate a defective alarm. Return it for service. WARNING: Do not apply excessive force on the "TEST " and "HUSH " buttons, this may damage the smoke alarm and may void the warranty. WARNING: Never use an open flame of any kind to test your alarm. The built in test switch enables testing of all electronic components and the horn. To accurately test the integrity of the sensing chamber use a smoke detector (aerosol) ® tester. We recommend using the LIFESAVER LT711 Smoke Detector Tester for this purpose. 7. 6 7. 6. 1 Maintenance: The smoke alarm is virtually maintenance free. However, under dusty or greasy conditions, a vacuum cleaner may be used to clean the exterior of unit (including slots on cover). We recommend a periodic monthly inspection of the smoke alarm to ensure that it is free of dirt. 8. 8. 1. 0 8. 1. 1 8. 1. 2 8. 1. 3 8. 1. 4 BATTERY TEST We recommend a weekly battery test. Switch off mains power OR unhinge the smoke alarm from its base plate. Switch on mains power OR hinge the smoke alarm back onto its base plate only when smoke alarm passes the above tests. The Green LED on the smoke alarm will come ON. 9. LIFESAVER MODEL LIF3010 WITH NC/NO RELAY If you have purchased and installed the LIF3010 smoke alarm with the NC/NO Relay, please note that the operation and features of this model smoke alarm is the same as the LIF3000. The LIF3010 smoke alarm has 7 terminals and they are colour coded. WARNING: THIS TERMINAL IS NOT ISOLATED FROM THE MAINS SUPPLY 9. 1 9. 1. 1 This seven terminal has a relay output (C, NC and NO): A relay output may have a power loading (See figure 9. 1). Figure 9. 1 WARNING: The loading power must be less than 5Ax250VAC/10Ax125VAC/10Ax30VDC The smoke alarms can be interconnected to a maximum of twenty-four pieces. (please see figure 9. 2) 9. 1. 2 Figure 9. 2 9. 1. 3 9. 1. 4 Test if smoke alarm is okay by operating remote test & hush plate connected to smoke alarm. LIFESAVER Model LIFTHC: CHIP FOR REMOTE TEST & HUSH OPERATION (see figure 9. 3 and figure 9. 4) Figure 9. 3 (top) 9. 1. 5 Figure 9. 4 (bottom) By inserting this LIFTHC chip into the smoke alarm as shown in the diagram, it will allow your smoke alarm to be wired to the remote test and hush plate (LIFTHP). If your smoke alarms are interconnected, you would require a LIFTHC chip for each smoke alarm. (see figure 9. 5) Figure 9. 5 9. 1. 6 LIFESAVER MODEL LIFTHP: REMOTE TEST AND HUSH PLATE: Figure 9. 6 Note: By installing this LIFTHP remote test and hush plate on the wall, it will allow you to test and hush your smoke alarm easily. The LIFTHP test and hush plate can be installed singly or if your smoke alarms are interconnected, only one plate is required. 9. 2 OPERATION OF REMOTE TEST & HUSH P ATE: Define system units: A system may be connected maximum of 24 units, they are SMOTEC 3786/1, LIFESAVER models LIF3000, LIF3010, 3800, 3800R, 4800R, 4800RL, Heat alarm model HA240, Visual Device model SL240 and Relay model RK10A/9. Note: Before testing a system, make sure all wires and the Remote Test & Hush Plate are connected to whole system units, LIF3000 series smoke alarms must have the LIFTHC Cards installed. If they have no LIFTHC Cards, in testing the system, their red LEDs will not light. 9. 2. 1 TEST button on LIFTHP 9. 2. 1. 1 To Activate: PRESS and Release TEST button to sound all smoke alarm/s and devices, the description as below: · LIF3000 series smoke alarms with LIFTHC cards should always keep sounding, their red LEDs will be latched on. Any LIF3000 series smoke alarm without the LIFTHC Card, its red LED will not light. [. . . ] Every second counts, so don't waste time getting dressed or picking up valuables. In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don't open that door!If inside door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFESAVER LIF 3010 SMOKE ALARM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFESAVER LIF 3010 SMOKE ALARM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.