User manual LG AS-H246TKA2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG AS-H246TKA2. We hope that this LG AS-H246TKA2 user guide will be useful to you.


LG AS-H246TKA2 : Download the complete user guide (879 Ko)

You may also download the following manuals related to this product:

   LG AS-H246TKA2 (2294 ko)
   LG AS-H246TKA2 ANNEXE 256 (1007 ko)

Manual abstract: user guide LG AS-H246TKA2

Detailed instructions for use are in the User's Guide.

[. . . ] s Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. ENGLISH WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. s Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING Plug in the power plug properly. · Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not operate or stop the unit by inserting or pulling out the power plug. · It will cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord. · It will cause electric shock or fire. [. . . ] CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. START/STOP BUTTON Operation starts when this button is pressed, and stops when the button is pressed again. ROOM TEMPERATURE SETTING BUTTONS INDOOR FAN SPEED SELECTION BUTTON JET COOL Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode. ) ENGLISH 1 TEMP. 2 1 OFF TIME hr. 3 3 4 4 8 7 2 5 6 5 6 7 8 (1) Operation Mode Cooling Operation Cooling Operation Healthy Dehumidifacation Operation Healthy Dehumidifacation Operation (Cooling Model) Heating Operation (Heat pump Model) (2) Operation Procedure 1st 2nd 3rd 4th Start/Stop Button OFF TEMP. TIME hr. Operation Mode Selection Button Room Temperature Setting Button Indoor Fan Speed Selection Button 2 4 1 3 Owner's Manual 7 Operating Instructions Cooling Operation Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling. 1 2 Press the Start/Stop Button. , Bee p Beep Select Cooling Operation. Each time the button is pressed, the operation mode is shifted in the arrow direction. TEMP. OFF TEMP. OFF TEMP. OFF TIME hr. TIME hr. TIME hr. TEMP. OFF Cooling Healthy Dehumidification Heating (Heat pump model only) TEMP. OFF TIME hr. TEMP. OFF TIME hr. TIME hr. Cooling Healthy Dehumidification 3 Set the temperature lower than the room temperature. · The temperature can be set within a range of 18°C ~ 30°C by 1°C . TEMP. OFF To raise the temperature TIME hr. To lower the temperature 4 Set the fan speed. · Select the fan speed in four steps-low, medium, high or CHAOS. · Each time the button is pressed, the fan speed mode is shifted. OFF TIME hr. Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. During Healthy Dehumidification Operation: If you select the dehumidification mode on the operation selection button, the airconditioner starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp. is not displayed in the remote control and you are not able to control the room temp. During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season. 8 Room Air Conditioner Operating Instructions Heating Operation(Heat pump model only) ENGLISH 1 2 TEMP. OFF Press the Start/Stop button. setting button or the JET COOL button again. 10 Room Air Conditioner Operating Instructions Vertical Airflow Direction Control ENGLISH The up/down airflow (Vertical Airflow) can be adjusted by using the remote control. NOTICE If you press the CHAOS swing button, the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze. Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner. [. . . ] · Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room. · Condensation occurs when the airflow from the air conditioner cools the warm room air. See page - The room has a peculiar odor. - It seems that condensation is leaking from the air conditioner. Does not cool or heat effectively. - · This is the protector of the mechanism. · Are the indoor unit's air inlet or outlet vents obstructed? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG AS-H246TKA2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG AS-H246TKA2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.