User manual LEXICON RV-8 V2.0 SERIAL PROTOCOL DEFINITIONS REV 1-8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEXICON RV-8 V2.0. We hope that this LEXICON RV-8 V2.0 user guide will be useful to you.


LEXICON RV-8 V2.0 SERIAL PROTOCOL DEFINITIONS REV 1-8: Download the complete user guide (271 Ko)

Manual abstract: user guide LEXICON RV-8 V2.0SERIAL PROTOCOL DEFINITIONS REV 1-8

Detailed instructions for use are in the User's Guide.

[. . . ] RV-8 Serial Protocol Definition Software Version 2. 0 Protocol Version: Major Rev 1 Minor Rev 8 Lexicon RV-8 Serial Communications Protocol Manufactured under license from Dolby Laboratories. "Dolby, " "Pro Logic, " and the double-D symbol are trademarks of Dolby Laboratories. "Surround EX" is a jointly developed technology of THX and Dolby Laboratories, Inc. , and is a trademark of Dolby. THX, Ultra and Ultra2 are trademarks of THX Ltd. , which may be registered in some jurisdictions. [. . . ] 7. 3. 8. 1 Packet Description Application Header: Command HOST_SLEEP Data Count 0 Application Data: N/A 0x12 0x00 7. 3. 8. 2 Data Description N/A 7. 3. 9 Get Communication Configuration This command is a request to the RV-8 for the current communications configuration for the serial port and protocol. The RV-8 responds to this command with a Communication Configuration Packet. 7. 3. 9. 1 Command Packet Description Application Header: Command DC_CMD_GET_COM_CONFIG Data Count 0 Application Data: N/A 0x2F 0x00 7. 3. 9. 2 Communication Configuration Response Packet Application Header: Command DC_RESP_COM_CONFIG Data Count 1 Application Data: Data[0] Configuration Register 0 0x8C 0x01 nn 7. 3. 9. 3 Data Description Data Word Bit Definition 0 0 Acknowledge Enable 0 1 Parameter Change Enable Acknowledge Enable: TRUE Indicates the RV-8 will transmit Acknowledge Notification's to the Host. FALSE Indicates the RV-8 will not transmit any positive Acknowledge Notification messages. Parameter Change Enable: TRUE Indicates the RV-8 will transmit any parameter change Notification as specified in the Parameter Change Notification Message. FALSE Indicates the RV-8 will not transmit parameter change Notifications. 19 Lexicon RV-8 Serial Communications Protocol 7. 3. 10 Set Communication Configuration The Set Communication Configuration Command allows the serial port user to set up the various serial port/ protocol configuration parameters. 7. 3. 10. 1 Command Packet Description Application Header: Command Data Count Application Data: Data[0] DC_CMD_SET_COM_CONFIG 1 Configuration Register 0 0x30 0x01 nn 7. 3. 10. 2 Data Description Data Word Bit Definition 0 0 Acknowledge Enable Acknowledge Enable: TRUE Indicates the RV-8 will transmit Acknowledge Notification's to the Host. FALSE Indicates the RV-8 will not transmit any positive Acknowledge Notification messages. The RV-8 will always transmit NAK error notification messages. 7. 3. 10. 3 RV-8 Response The data values transmitted will be copied over to the registers stored in nonvolatile RAM. 7. 3. 11 Set Mute The Set Mute Command message allows the RS-232 users to set/clear the RV-8 mute state directly. 7. 3. 11. 1 Command Packet Description Application Header: Command Data Count Application Data: Data[0] DC_CMD_SET_MUTE 1 Mute State 0x31 0x01 nn 7. 3. 11. 2 Data Description MUTE State: Value Definition 0 UNMUTE 1 2 USER MUTE FULL MUTE Description The user mute state is set to unmuted. The system volume decrements by the specified user amount as set in the OUTPUT LEVELS Menu. The system is fully muted. 7. 3. 11. 3 RV-8 Response 20 Lexicon RV-8 Serial Communications Protocol The RV-8 will set the mute state according to the value transmitted. The RV-8 may still be full muted if other conditions require the audio path to be muted. This is only a direct access to the user mute state. 7. 3. 11. 4 Data Validation The data value transmitted to the RV-8 will be verified as a valid value. If it is valid the RV-8 will set/clear the mute and respond with an ACK Packet. If the data value is invalid the RV-8 will respond with a DC_INVALID_DATA error NAK. 7. 3. 12 Send Display String Command This command allows the Host to send a 40-character string to the RV-8 for display on the OSD and Front Panel Display. This can be configured such that the message will display only on the FPD, if desired. 7. 3. 12. 1 Packet Description Application Header: Command Data Count Application Data: Data[0] Data[1]-Data[DataCount-1] DC_CMD_SET_DISPLAY_STR 0x33 Number of characters in the nn DisplayStr + 2 DisplayFlags DisplayStr nn ch ch ch . . . 0x00 7. 3. 12. 2 Data Description Display Command Flags: Word Bit Definition 0 0 FPD only: If set TRUE, the display string will only be sent to the FPD device for display. 0 7 Undefined. Display String: Data Type: Max Length: Null (0x00) terminated ASCII character string. [. . . ] RV-8 has detected Video Sync for current video input RV-8 can not detect Video Sync for the current video 7. 3. 23 Get Zone 3 Status This command is a request to RV-8 for current Zone 3 Status. RV-8 will respond with "Zone3 Status Packet". 7. 3. 23. 1 Command Packet Description Application Header: Command MC_CMD_GET_ZONE3_STATUS 0x3F Data Count 0 0x00 Application Data: N/A 7. 3. 23. 2 Zone 3 Status Response Packet Application Header: Command MC_RESP_ZON_STATUS Data Count 5 Application Data: Data[0] Zone3 Volume Data[1] Assigned Zone 3 Input Data[2] Zone3 Mute Active Data[3] Reserved Data[4] Zone3 Balance 0x95 0x05 nn nn nn 0 nn 7. 3. 23. 3 Data Description Zone 3 Volume: Data Type: Max: Min: Signed 8-bit integer (2's compliment) +12 (0x0C) (12 dB) -80 dB (0xB0) (-80 dB) Assigned Zone 3 Input: Indicates the Zone 3 input that is currently assigned for the Zone 3 outputs. Definition/Conversion: Appendix F RV-8 Input Ids Zone3 Mute Active: Data Type: TRUE: FALSE: Reserved 34 Boolean. Zone 3 Outputs are not active. Lexicon RV-8 Serial Communications Protocol Zone 3 Balance: Data Type: Max: Min: Signed 8-bit integer (2's compliment) 16 (0x10) (Full Right) -16 (0xF0) (Full Left) 7. 3. 24 Set System Volume This command is a request to the RV-8 to set the system volume with the value in this packet. 7. 3. 24. 1 Command Packet Description Application Header: Command MC_CMD_SET_SYS_VOLUME Data Count 1 Application Data: Data[0] Value 0x40 0x01 nn 7. 3. 24. 2 Data Description Value: Data Type: Max: Min: Signed 8-bit integer (2's compliment) +12 (0x0C) (12 dB) -80 (0xB0) (-80 dB) 7. 3. 24. 3 RV-8 Response The RV-8 will assign the value from the packet to the system volume. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEXICON RV-8 V2.0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEXICON RV-8 V2.0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.