User manual LEXICON MC-12 EQ REV 1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEXICON MC-12 EQ. We hope that this LEXICON MC-12 EQ user guide will be useful to you.


LEXICON MC-12 EQ REV 1: Download the complete user guide (3283 Ko)

Manual abstract: user guide LEXICON MC-12 EQREV 1

Detailed instructions for use are in the User's Guide.

[. . . ] MC-12 Controller EQ User Guide 3 Oak Park Bedford, MA 01730-1413 USA Tel 781-280-0300 Fax 781-280-0490 www. lexicon. com Customer Service Telephone 781-280-0300 Sales Fax 781-280-0495 Service Fax 781-280-0499 email csupport@harmanspecialtygroup. com Product Shipments 16 Progress Road Billerica, MA 01821-5730 USA Manufactured under license from Dolby Laboratories. Dolby, Pro Logic, Surround EX, and the double-D symbol are trademarks of Dolby Laboratories. DTS, DTS-ES, Neo:6, and DTS 96/24 are trademarks of Digital Theater Systems, Inc. Lexicon, Logic 7 and the L7 logo are registered trademarks of Harman International Industries, Inc. [. . . ] Improper microphone placement for the microphone check. The microphones SHOULD NOT be positioned: Rear Left Side Left In separate locations In locations scattered throughout the listening room In an obstructed line-of-sight path with the loudspeakers In a location obstructed by furniture and other fixtures Within 2 feet (0. 61m) of loudspeakers and walls More than 30 feet (9. 14m) from any one loudspeaker. Rear Right Front Left Microphone Side Right Center Subwoofer Front The listening room to the left shows improper microphone placement for the microphone check. The microphones are scattered throughout the listening room in locations that are neither centered between nor equidistant from the front left and right loudspeakers. In addition, the microphones are positioned in obstructed locations on the floor and on seat cushions. 2-7 Configuring the MC-12 for EQ PERFORMING THE MICROPHONE CHECK MAIN MENU MODE ADJUST AUDIO CONTROLS SETUP SETUP INPUTS SPEAKERS REAR PANEL CONFIG DISPLAYS VOLUME CONTROLS TRIGGERS LOCK OPTIONS LIVE!CALIBRATION SPEAKER SETUP SET CROSSOVERS CHECK MICROPHONES AUTOMATIC MANUAL SET CROSSOVERS BEFORE CALIBRATING CHECK MICROPHONES GROUP MICROPHONES INTO A BUNDLE IN THE MIDDLE OF THE ROOM PRESS V TO BEGIN MIC CHECK CHECK MICROPHONES CHECKING FOR SILENCE PLEASE WAIT Lexicon MC-12 Controller CHECK MICROPHONES CHECKING MICROPHONES PLEASE WAIT 1. Press the and arrow buttons to highlight the CHECK MICROPHONES procedure. The CHECK MICROPHONES screen (shown above) opens on the on-screen display, emphasizing the importance of proper microphone placement to achieve the desired automatic calibration results. Refer to Positioning the Microphones for the Microphone Check (page 2-6) to ensure that the microphones are properly positioned for the microphone check. The CHECKING FOR SILENCE message (shown above) appears on the on-screen display while the MC-12 determines the relative noise level of the listening room and the internal noise level of the microphones. After eliminating microphones that are not detected or not functioning, the MC-12 calculates an average microphone level. The CHECKING MICROPHONES message (shown above) appears on the on-screen display while the MC-12 confirms the microphone level calculated during the silence check. To do this, the MC-12 sends alternating calibration noise signals to the front left and right loudspeakers, eliminating microphones that detect the signal at an unusually low or high level. Then, the MC-12 determines the appropriate output level for the calibration noise signal used during automatic calibration. Note: The MC-12 outputs calibration noise signals between 55 and 95dB, starting at 55dB and increasing in 5dB increments until the microphones detect the required level. If calibration noise signals become too loud, press the arrow button to cancel automatic calibration. 2-8 EQ User Guide The CHECK MICROPHONES results screen (shown to the right) opens on the on-screen display when the MC-12 finishes checking the microphones. (The MC-12 refers to the microphones as 1, 2, 3, and 4 based on the microphone input connector to which the microphone is connected. ) · · · Configuring the MC-12 for EQ CHECK MICROPHONES MIC 1 ERROR MIC 2 OK MIC 3 OK MIC 4 OK PRESS V TO VIEW DETAILS PRESS X TO CONTINUE Do not disconnect the microphones from the microphone input connectors. If the microphones are disconnected, perform the microphone check again before performing automatic calibration. OK indicates that the microphone passed the microphone check. ERROR indicates that the microphone did not pass the microphone check. Press the arrow button to view more detailed results for the selected microphone. The CHECK MICROPHONES Results table on the next page describes all possible results. Once a successful microphone check has been performed: · The MC-12 retains the determined microphone level until the SPEAKER SETUP menu is closed. Once this menu is closed, another microphone check is required before automatic calibration can be performed. 2-9 Configuring the MC-12 for EQ Lexicon MC-12 Controller Result (MICROPHONE) OK (MICROPHONE) NOT DETECTED Description The microphone detected calibration noise signals without error. N/A Troubleshooting · Examine the microphone input connection to ensure that the microphone is properly connected to the MC-12. Make sure the microphone cable plug is fully inserted for a solid connection. · Examine the microphone input connection to ensure that the microphone is properly connected to the MC-12. Make sure the microphone cable plug is fully inserted for a solid connection. [. . . ] Miss Single Married Divorced Widowed First Name Last Name Company Title Mailing Address City State Zip Telephone Number Fax Number Email Address Product Model Purchase Date Version Serial Number Where did you purchase this product?Age Education Household Income Under 18 High School Under $20, 000 18-24 College $20, 000 to $34, 999 25-34 Graduate School $35, 000 to $49, 000 35-49 Certificate: $50, 000 to $74, 999 50-64 $75, 000 to $99, 000 65+ $100, 000+ How did you learn about this product?Choose one: Friend Store salesperson Advertisement Colleague Store display Magazine Article Teacher Received as a gift Own other Lexicon products Which of the following were most important in the selection of this product?Sound Quality Value for price Durability Features Brandname Other: What are your three favorite magazines? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEXICON MC-12 EQ




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEXICON MC-12 EQ will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.