User manual LEXIBOOK SM1600

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEXIBOOK SM1600. We hope that this LEXIBOOK SM1600 user guide will be useful to you.


LEXIBOOK SM1600 : Download the complete user guide (714 Ko)

You may also download the following manuals related to this product:

   LEXIBOOK SM1600 (718 ko)
   LEXIBOOK SM1600 (998 ko)
   LEXIBOOK SM1600 (1523 ko)
   LEXIBOOK SM1600 (789 ko)
   LEXIBOOK SM1600 (745 ko)

Manual abstract: user guide LEXIBOOK SM1600

Detailed instructions for use are in the User's Guide.

[. . . ] HOUR/+/MAX: shows maximum temperature; adjusts clock, alarm, date & year and temperature alarm values. MIN/-/MIN: shows minimum temperature; adjusts clock, alarm, date & year and temperature alarm values. ON/OFF/°C/°F: toggles between °C and °F, 12 and 24 hour format, Alarm 1 & 2 on and off; disables (resets) high & low temperature alarms. CHANNEL: scrolls through remote channels Outside, Outside 2 and Outside 3); scrolls through local and remote channels (Outside, Outside 2 and Outside 3) in (high & low) temperature alarm mode; activates learn process. [. . . ] To place it, use the same precautions as for the remote sensor. SETUP SYNCHRONIZATION Automatic Learn Function 1 - Learn function executes automatically and runs for approximately 3 minutes when the batteries are first installed in the receiver. 2 - Within these 3 minutes, the receiver picks up the temperature & humidity signals from the remote sensor and displays the readings. Manual-Learn (Searching for Remote Signals) If a new remote sensor is added or if the signal is lost (outdoor display blinking), the learn function must be executed again. 6 Copyright © Lexibook 2004 Press and hold CHANNEL for 3 seconds to start. The 'Channel' symbol will flash and unit will beep as each remote sensor is detected. Temperature & humidity readings of remote sensor display on the receiver. Note: Auto/Manual Learn will not operate while the radio controlled clock is receiving DCF77 signals. CLOCK AND DATE SETTINGS RADIO CONTROL CLOCK 1 - The SM1600 is designed to automatically synchronize its calendar clock once it is brought within a range of 1500 km of the Frankfurt DCF77 radio signal. When the SM1600 is within this range, its radio-control mechanism will override all the manual settings. 2 - When receiving radio signal, the Radio Tower symbol starts to blink. A complete reception generally takes several minutes, depending on the strength of the radio signal. Copyright © Lexibook 2004 7 3 - When the reception is complete, the Radio Tower symbol will stop blinking and remain solid. 4 - For an optimal reception, place the clock away from metal objects and electrical appliances (i. e. MANUAL CLOCK AND DATE SETTINGS Clock 1 setting 1 - Press and hold MODE/SNOOZE for 3 seconds to enter the clock Mode setting mode (the CLOCK 1 symbol will appear, and the time will Hour/+/Max flash). Minute/-/Min 2 - Press Hour/+/Max to set the hour and Minute/-/Min to set the On/Off/C/F minutes. 3 - Press ON/OFF/°C/°F during the clock settings to alternate between the 12 and 24 hour display. Press the Hour/+/Max Max key to set the month and the Minute/-/Min to set the date. Your weather station will automatically adjust the corresponding weekday. Press the Hour/+/Max to move the year upwards and Minute/-/Min Min to move the year downwards. Press MODE/SNOOZE one last time to accept your settings and return to the normal display. Note: If you do not press any key for one minute, the clock will accept the last settings entered. Your weather station will display the 29th day on bissextile years. 8 Copyright © Lexibook 2004 Clock 2 Settings (Dual Time) 1 - Scroll to Clock 2 using MODE/SNOOZE. 2 - Press MIN/-/MIN or HOUR/+/MAX key to change the hour (in hour increments/decrements relative to Clock 1). ALARM SETTING Alarm 1 and Alarm 2 Setting Scroll to Alarm1 mode (Alarm2 mode) using MODE/ SNOOZE. If not manually interrupted, the alarm sound will automatically stop after one minute. Copyright © Lexibook 2004 9 MOON PHASE Throughout the 28 days of the lunar month, the aspect of the moon changes. Indeed, the moon, being spherical, is always half lightened up by the sun. [. . . ] Otherwise, re-synchronize receiver by holding CHANNEL for 3 seconds until a beep is heard. Ensure the remote sensor is out of direct sunlight, and away from sources of heat. - Make sure remote sensor is away from sources of electrical disturbance. The temperature measurement of remote sensor and receiver does not match. Temperature reading of outdoor remote sensor seems to high. Receiver is no longer receiving remote sensor signals or display. Copyright © Lexibook 2004 17 ACCESSORIES Additional sensors: Measure temperature and hygrometry in other places! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEXIBOOK SM1600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEXIBOOK SM1600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.