User manual LEITZ PRADOVIT-F

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEITZ PRADOVIT-F. We hope that this LEITZ PRADOVIT-F user guide will be useful to you.


LEITZ PRADOVIT-F : Download the complete user guide (4210 Ko)

Manual abstract: user guide LEITZ PRADOVIT-F

Detailed instructions for use are in the User's Guide.

[. . . ] that Cords the lid Connecting The motor operation to the Mains Supply of from the prodovit mains is designed of for in the be stored properly. a way 50 cycles, between able check according the 110/125 V, 110/125 V, 60 cycles or 220 V, 50 cyA. motor to be used for voltages is availTherefore the supply also Note must be connected current. A universal as well. 110-240 V and 50-60 cycles This model and to the prevailing type the voltage before the data chamber connecting panel lid. projector. on the inside of the magazine at the The projection-lamp same voltage. must also be rated Connecting line the Remote Control Cable control cable with the red on the opposite the red dot Plug in the remote on the plug back of the body. 4 Push the plug home firmly. ~ . ~ 10422-31 ~ Operation Switching On and 011 both buttons symbol control the projector only is the By The By depressing switched button doing with on. [. . . ] The projection ning sible af a show image lens to is focused obtain at the beginposthe sharpest levelling. You image also can helps adjust to the level height of milled the projected This on uneven proby turning the two screws. on the screen. the projector more surtaces. Do not tilt vided up the projector than for by the levelling adjustment. 8 Operating the slide changer switching off the projector. turning of the arrow the the milled by hand alter transport changer button manu- magazine knob in the direction moves the slide 9 The motor and gears need no maintenance, be oiled. of and the pradovit must never Maintenance Opening the Lamp House. Disconnect the projector before opening the lamp house!The lamp house cover will swing open when you gently lift the spring catch inside the magazine chamber. To close, push down the lamp house cover from the outside until the spring catch engages again. 10 . , ~. . . 10433·31 Taking off the side panel. Inserting and changing the projection lamp. The side panel which carries the name "prodovit" can be pulled upwards after first maving the twa holding springs ta the side. Before doing so, the screw which holds the springs, must be slightly losened and depressed. First lift out the lamp chimney. The prajection lomp 300 or 500 watt with pin-type-cap G 17 q far pradovit-f is pushed in firmly. The pins in the cap of the lamp must be guided exactly into the cutouts of the socket. The low voltage lamp 12 V/100 watt for the pradovit-n has twa guide pins at the lamp cap. Push the low voltage lamp in the cutouts af the lamp socket and turn it to the right until both pins engage in the bayonet fitting. When taking out the lamp, push it down first and turn to the left to disengage the bayonet fitting. 11 10430-31 Centering the Projection Lamp. For centering pinhole a white obtained shown slide piece of the reflected jection-lens. in front centering is observed 'can insert the The above the ideal double the low reflected illustration focusing image voltage image of the image represents With the to the obove With it is aimed into the film image of po per the The filament by holding of the proeasily screw be as for the pradovit-f. field for of the filament lamp get as a homogeneous os possible. the pradovit-n The best position by turning must be seen exactly in the illustrotion. the lamp filoment. 12 Cleaning. words are projection All coated opening the of For (not the lamp house you with can easily as the heat prosable the the other lenses, This withdraw holder the lamp aspheric the chimney condenser, especially only a soft, cloth). appreciably increases trast of the projected LEITZ stands faces are dirt. still hard coating up to normal as any sensitive the brilliance and conimage. Although the is highly resistant the glass optical marks Remove with of course, and any and surother major fluffcleaning, as well movable use condenser cleaning, high-quality to finger glass lens, an antistatic lens simply exposed with lens To clean So avoid touching any glass and mirror a soft, surface with your fingers. [. . . ] voltage, a 230 volt above If your lamp and AC below supply the normal carries supply The pradovit-f and cap. disk 500 watt an overone, or that the then you should in place even new a cases choose, a lamp lamp, for instance, for 240 volts. to the aca 11O-volt it otherwise or apprecipremature causes; useless In connectian for the lamp the 500 watt as well code is fitted with the of the 220-volt check 2nd heat absorbing 37915 C is essential. The guide immediately guide lamp disk and disk in has lamps and as the guide number in the milled housing This of the on in extreme Before voltage tual lamp worse will housing filter down into of the fitting marked must still not out very easily for on it corresponds For instance, supply, to knocks whether any are of be connected immediately. absorbing mains voltage. longitudinal cutouts of the condensor- to a 125-volt Projection tightened is fitted front no a 220 volt sensitive establish is due to burn tilting can lamps the lamp the ventilation are also able ers lamp claims reflector. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEITZ PRADOVIT-F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEITZ PRADOVIT-F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.