User manual LEICA HDS7000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEICA HDS7000. We hope that this LEICA HDS7000 user guide will be useful to you.


LEICA HDS7000 : Download the complete user guide (3266 Ko)

Manual abstract: user guide LEICA HDS7000

Detailed instructions for use are in the User's Guide.

[. . . ] HDS7000 User Manual Version 1. 1 English HDS7000, Introduction 2 Introduction Purchase Congratulations on the purchase of a HDS7000 instrument. This manual contains important safety directions as well as instructions for setting up the product and operating it. Read carefully through the User Manual before you switch on the product. Product identification The type and the serial number of your product are indicated on the type plate. Enter the model and serial number in your manual and always refer to this information when you need to contact your agency or Leica Geosystems authorised service workshop. [. . . ] Settings on the notebook: On the notebook you can access the data on the HDS7000 using the web browser or an FTP client: • Enter the IP address of the HDS7000 into your web browser: http://<IP> or • Enter the IP address directly at the FTP client. The scan files on the HDS7000’s hard disk are listed in their subfolders in the web browser/FTP client. You can open the scan files or download them to your notebook. HDS7000, Scanning 97 HDS7000, Scanning • • • 98 The firewall of the notebook should be deactivated to avoid disturbing the connection to the scanner. The proxy settings of the web browser should be deactivated or an exception for the web page must be declared. Enter user name “scans” for establishing an FTP connection to be able to delete scans. Deleted files cannot be restored. 3. 12. 3 Access Connecting the HDS7000 by Wi-Fi Select Main Menu, Settings . Description Configuration of the laptop In the Settings menu enable the Wireless option for a Wi-Fi connection. In the Wireless Network Connections list the HDS7000 is listed as hds7000xxxx with xxxx = serial number. If scanner is not listed select Refresh network list, after some seconds the system automatically will find the HDS7000. Open your web browser and in the address field enter the Wi-Fi IP address http://192. 168. 3. 1 In Wi-Fi mode the general IP address 192. 168. 3. 1 is used instead of the unique scanner IP address. Web browser settings HDS7000, Scanning 99 HDS7000, Scanning 100 3. 13 Start page Operating the HDS7000 using a Web Browser The HDS7000 can be operated via Ethernet connection or via Wi-Fi in a local network directly using a web browser. Enter the IP address of the HDS7000 into the address field of your web browser. For example: http://172. 20. 0. 100 Fixed address for Wi-Fi: http://192. 168. 3. 1 The buttons on the left side of the screen guide directly to the following menu items: • Scan • Info • Scanmanagement • Status • Help • Scan predefined If the IP address is extended to show the menu’s shortcut commands, you can go directly to the desired page. For example: http//172. 20. 0. 100/info Further shortcuts for menu points include: • • • • • • /home /info /scan /scan/predefined /scanmanagement /status • • • • • /config (password protected) /debug /firmware /camera /systemtest • • • • • • /report /backlight /profiler /statistic /error /error/help HDS7000, Scanning 101 HDS7000, Scanning Scan menu in web browser For example: http//172. 20. 0. 100/info 102 The settings for the web browser scan interface are the same as for the interface of the onboard display. Refer to chapter "3. 6. 3 Scan with User Defined Settings" for details. HDS7000, Scanning 103 HDS7000, Troubleshooting 104 4 HDS7000 Troubleshooting Problem Instrument does not boot. Possible Cause(s) Suggested Remedies Disconnect from AC power supply or external battery. Reconnect cables and external power sources, insert all internal batteries and switch on again. Dust, debris or fingerprints Use glass cleaning kit to clean on optics of rotating mirror. the specific areas. Missing points in scans. Instrument too cold. The instrument is operated Start scanning, for example at a temperature lower perform some preview scans, as than -10°C. The instrument is operated Put the HDS7000 in a cool and shady place, leave it powered in at a temperature higher standby mode only. than +45°C. Problem Control panel does not work correctly. Possible Cause(s) Dirt on the touch screen. Suggested Remedies Turn off the instrument and clean control panel with mild cleaning supplies and a soft tissue. HDS7000 Battery Problem When switching on the instrument or starting a scan, the system switches off automatically. When switching on the instrument or starting a scan, the system switches off automatically even though it was totally recharged. Possible Cause(s) Capacity of battery is too low. Suggested Remedies Recharge or change battery. Battery charger is defective. Examine the cabling and pay attention to damages, which for example can cause loose contacts or short circuits. [. . . ] EN 60825-1) Centering accuracy: 0. 5 mm /1 m Laser dot diameter: < 1. 5 mm @ 1. 5m Selectable on/off Data transfer Data storage Data integrity monitoring Ethernet or USB 2. 0 device (two ports) 64 GB flash drive (integrated) and 2x 32 GB USB flash drive (external) Self-check at startup 7. 3. 1 Power supply Electrical • • Batteries: 14. 4 V DC Battery charger: 100 -240 V AC Power consumption Battery type < 65 W (on average) • • • • • Type: Li-Ion (2 x Lithium-Ion pack with protective circuit, 4S2P) Voltage (pack): 14. 4 V Capacity (pack): 4. 9 Ah Internal: 1 External: 1 Power ports Duration Charging cradle Integrated battery: > 2. 5 h (at room temperature) • • • • Output voltage: 16. 8 V DC Power status: LEDs indicate charging status and capacity level Input voltage: 100 – 240 V AC, 50 - 60 Hz Output voltage: 24 V DC AC power supply HDS7000, Technical Data 145 HDS7000, Technical Data 146 7. 4 Environmental specifications Environmental Temperature Type HDS7000 AC power supply Battery Charging cradle Operating temperature [°C] -10 to +45 -10 to +45 -10 to +45 0 to +40 Storage temperature [°C] -20 to +50 -20 to +50 0 to +30 -20 to +50 Protection against water, dust and sand Type HDS7000 AC power supply Battery Charging cradle Humidity Lighting Non-condensing Fully operational between bright sunlight and complete darkness. Protection IP53 (IEC 60529) with additional USB plugs at side cover IP20 (IEC 60529) IP53 (IEC 60529) IP20 (IEC 60529) 7. 5 Dimensions and Weight Physical Instrument HDS7000 AC power supply Battery Charging cradle Dimensions [mm] (D x W x H) 286 x 170 x 395 167 x 67 x 35 88 x 170 x 61 107 x 170 x 30 Weight [kg] 9. 8 0. 54 1. 2 0. 48 Tilt axis height 285 mm HDS7000, Technical Data 147 HDS7000, Technical Data 148 7. 6 Standard Accessories Accessories • • • • • • • • • • • Scanner and accessory transport case 2x 32 GB memory stick, 1x USB memory plug Additional rechargeable integrated battery Charging/Power cable Ethernet cable AC cable Battery charger/AC Power supply Battery charging cradle for integrated battery Cleaning kit CycloneTM-SCAN software 1 year CCP Basic support agreement Notebook PC, tablet PC or PDA HDS scan targets and target accessories Service agreement for HDS7000 Extended warranty for Leica HDS7000 External camera kit (third party product) External battery Tripod, Tripod star Rolling base Hardware Options • • • • • • • • Notebook PC for scanning with Cyclone software Component Processor Sytem memory RAM Network connection Data connection Display Operating system Minimum requirements 1. 7 GHz Pentium M or greater 1 GB or greater, 2 GB for Windows Vista Ethernet Ethernet, Wireless LAN SVGA or OpenGL accelerated graphics card (with latest drivers) Windows XP Professional (SP2 or higher), 32 or 64 Windows Vista (32 or 64) Windows 7 (32 or 64) File System NTFS Minimum requirements for modeling are different. Please refer to Cyclone datasheet for specifications, available at your Leica Geosystems dealer. Data can be transferred automatically after scan process. HDS7000, Technical Data 149 HDS7000, Technical Data 150 7. 7 Wi-Fi technical data Wi-Fi Standard: Frequency band: Output: FCC IC: IEEE 802. 11b/g 2412 MHz - 2462 MHz (channel 1 - 11) <20 dBm M4Y-AG623C 7. 8 Conformity to national regulations Conformity to National Regulations • • FCC Part 15 (applicable in US) Hereby, Leica Geosystems AG, declares that the HDS7000 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEICA HDS7000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEICA HDS7000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.