User manual LARSON EASY-VENT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LARSON EASY-VENT. We hope that this LARSON EASY-VENT user guide will be useful to you.


LARSON EASY-VENT : Download the complete user guide (419 Ko)

Manual abstract: user guide LARSON EASY-VENT

Detailed instructions for use are in the User's Guide.

[. . . ] Measurements NOTE: Measure height from the top of the door opening (underside of the trim board) down to the bottom threshold. Take two measurements as shown in Figure 2 to determine the threshold angle. You will need this information as you install the hinge z-bar. STEP 1 FIGURE 1 Width A Width B Width C Height A Height B FIGURE 2 A B A A B A B C C PINCH EXPANDER AND VINYL SWEEP FIGURE 1 FIGURE 2 STEP 2 Determine Left or Right Hinge Side Your Larson storm door is REVERSA-HINGE meaning that the door is designed for either right hand or left hand hinge installation. Looking at your door opening from the outside, determine which side you want the hinge attached. [. . . ] Bottom Cut: Cut the Z-bar to length, using the same procedure used to cut the hinge side Z-bar in Step 4. Installation: Set the Z-bar in place between the door and the wood jamb. Allow a 1/8"-3/16" gap between the door and the latch-side Z-bar. Make sure the door closes freely without hitting the Z-bar, but also makes good contact with the weatherstripping. Fasten Z-bar using #8x1" painted pan head screws through pre-drilled holes provided in Z-bar. OPENING HEIGHT (UNDERSIDE OF DRIP CAP TO TOP OF SILL) FIGURE 11 FIGURE 12 STEP 10 Install Screw Cap Covers · After the door is installed, apply the drip cap screw cover. Start at one end, snap the cover on working your way towards the other end. NOTE: Be sure to insert the edge toward the door first, then snap in outer edge. · Cut the latch and hinge z-bar screw covers to length--matching the z-bar lengths respectively. · Attach the latch and hinge z-bar screw covers per Figure 12 as described above. TOP Z-BAR (DRIP CAP) SCREW COVER VINYL SCREW COVER HINGE Z-BAR SHOWN HINGE Z-BAR LATCH Z-BAR INSTALLED POSITION FIGURE 13 202220566 EASY VENT 5 STEP 11 Some door models have a protective tape over the door frame on both outside and the inside surface. Adjust the bottom expander so that the vinyl sweeps touch the door threshold. The slotted holes in the expander should be located on the inside of the door. Centrally locate the two #6 x 3/8" pan head screws in the slot to allow for future adjustments. Drill 3/32" diameter pilot holes for the screws, being careful not to drill all the way through to the front face of the door. NOTE: Pilot holes must be drilled or screws will break! Remove Protective Tape and Adjust Bottom Expander #6 x 3/8" PANHEAD STAINLESS #6 x 5/8" FLATHEAD SCREW STEP 12 Refer to separate instructions packaged in the hardware box. Install Latch and Strike Hardware STEP 13 This door has a retractable screen located in the masterframe head. · To ventilate make sure sash lock is unlocked, then pull down on top insert. · If the screen comes out of the track, it should be pushed back in place before retracting or simply close the insert and the screen will reposition itself. NOTE: Slow, steady operation should be used to open and close screen. Glass Sash/ Screen Operation 6 EASY VENT 202220566 EasyVent Series Storm/Screen Door CLOSER INSTRUCTIONS NOTE: Be sure door opens and closes freely before installing the closer. STEP 1 CLOSER ASSEMBLY PREPARATION · Slide hold-open washer onto closer rod as shown. Pull rod out of closer so that there is approximately a 1/4" gap per Figure 1 (insert small screwdriver in rod hole to provide pulling grip). Attach closer rod to side jamb bracket (short connecting pin) with open side of jamb bracket toward storm door (see arrow on bracket). · Close and latch door. FIGURE 2 FIGURE 1 1/4" Closer Installation "HOLD OPEN" WASHER CLOSER FLANGE EXTEND ROD 1/4" OUT 1/4" FROM DOOR #10 X 1 1/2" SCREWS HINGE SIDE JAMB TOP CLOSURE #10 X 5/8" SCREW #10 x 1-1/2" ROUND HEAD LONG CONNECTION PIN DOOR BRACKET SHORT PIN LONG PIN TYP. 1" SASH LOCK SHORT CONNECTING PIN SIDE JAMB BRACKET BOTTOM CLOSER 202220566 EASY VENT 7 STEP 2 Closer Assembly Installation · Fasten jamb bracket to jamb with four #10x1-1/2" screws. Aluminum Skin--Non-abrasive paste wax may be used on your door's outer surface to help keep the finish looking new. [. . . ] NOTE: On two closer models adjust each closer individually (with the other closer being disconnected from the door); the closing speed should be the same for each closer). If more latching force is desired, the jamb bracket may be moved up to 1" away from the door (rather than the recommended 1/4"). NOTE: moving the jamb bracket further from the door reduces the door opening. Raise expander or leave window open to allow air to escape. Sash Balance protruding from insert Balance not seated correctly. Door does not close properly Hinge may have been attached too close to the front edge of the door. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LARSON EASY-VENT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LARSON EASY-VENT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.