User manual LACIE 12BIG RACK STORAGE SERVER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LACIE 12BIG RACK STORAGE SERVER. We hope that this LACIE 12BIG RACK STORAGE SERVER user guide will be useful to you.


LACIE 12BIG RACK STORAGE SERVER : Download the complete user guide (3806 Ko)

You may also download the following manuals related to this product:

   LACIE 12BIG RACK STORAGE SERVER QUICK INSTALL (1184 ko)
   LACIE 12BIG RACK STORAGE SERVER QUICK INSTALL (1190 ko)
   LACIE 12BIG RACK STORAGE SERVER QUICK INSTALL (1187 ko)
   LACIE 12BIG RACK STORAGE SERVER QUICK INSTALL GUIDE (1193 ko)
   LACIE 12BIG RACK STORAGE SERVER GUÍA RÁPIDA DE INSTALACIÓN (1182 ko)
   LACIE 12BIG RACK STORAGE SERVER QUICK INSTALL GUIDE (1179 ko)

Manual abstract: user guide LACIE 12BIG RACK STORAGE SERVER

Detailed instructions for use are in the User's Guide.

[. . . ] LaCie 12big Rack Storage Server User Manual Table of Contents page 1 Table of Contents 1. Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safe Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In this section the System Event Log (SEL) information and the event list are shown. A maximum of 1023 events can be displayed; the older ones will be removed when there are more than 1023. They can be cleared or refreshed manually. LaCie 12big Rack Storage Server User Manual The Management GUI page 25 5. 3. Reading This section offers a visual display of all board sensor readings. Below is the list of all onboard sensors. Table 11 - On-Board Sensors Sensor Number 0 1 2 3 Sensor Name Watchdog IPMI Info-1 IPMI Info-2 Init Agent Err Sensor Type Watchdog OEM OEM OEM Event/Reading Type Sensor Specific OEM OEM Generic digital Discrete 03h state asserted/deasserted OEM OEM Discrete Readings Available None 00h - Internal Error 01h - Event Overflow 00h - Internal Error 01h - Event Overflow None 4 Sensor Modif System Event 00h - Set Sensor Hysteresis 01h - Set Sensor Threshold 02h - Set Sensor Event Enable None None None None None None None None None None None None None None None None None None None None 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Temp CPU0 Temp CPU1 Temp DIMM#1 Temp DIMM#2 Temp DIMM#3 Temp DIMM#4 Temp DIMM#5 Temp DIMM#6 Temp DIMM#7 Temp DIMM#8 Temp DIMM#9 Temp DIMM#10 Temp DIMM#11 Temp DIMM#12 Temp PCIe Zone PowerOK 1. 5v PowerOK 1. 1v PowerOK ATX PowerOK_0Vcore PowerOK_0Vtt Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Temperature Power Supply Power Supply Power Supply Power Supply Power Supply Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Threshold Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific LaCie 12big Rack Storage Server User Manual The Management GUI page 26 Sensor Number 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Sensor Name PowerOK_0VDDQ PowerOK_01. 8v PowerOK_1Vcore PowerOK_1Vtt PowerOK_1VDDQ PowerOK_11. 8v IPMB Sel State IPMB Link State CPU0 Status CPU1 Status Memory Err Post Value BMC Reboot Ver Change IPMC Ver Change FPGA Ver Change BIOS Board Reset Sensor Type Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Event Logging Disabled IPMB Link State Processor Processor Memory OEM Platform Alert Version Change Version Change Version Change OEM Event/Reading Type Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Sensor Specific Generic digital Discrete 03h state asserted/deasserted Usage State Sensor Specific Digital Discrete Sensor Specific Sensor Specific Sensor Specific Sensor Specific OEM Discrete Readings Available None None None None None None None None None None None None None None None None None 42 43 44 45 46 47 48 MB Application MB State GEM Quiesced GEM AC Feed GEM Battery Power Button ACPI State System Event FRU State Module/Board Power Unit Battery Button Type ACPI Power None None None None None None None LaCie 12big Rack Storage Server User Manual The Management GUI page 27 5. 4. Remote Power/Reset This section allows you to power down, shutdown, reset and power cycle the board. 5. 6. Component Upgrade This section allows the firmware of the Web Management Interface to be upgraded. Then click on File Upload. Table 12 - Enclosure Impact Command Reset Power Cycle Payload Impact Immediately reboots the enclosure in the same way as pressing the Reset button. Powers down and restarts the enclosure. The current POST value is also displayed on this page. Fig. At this point it is possible to select the component to upgrade. To start the KVM, click on the button KVM (Keyboard Video Mouse). A safety warning may pop up and ask if the application can be started. A new window will appear and display what is shown on the computer (12big Rack Storage Server-ATX). The mouse needs to be configured depending on the installed operating system. To do so, when the KVM is started, click on Tools, located on the menu bar, then on Mouse and select the appropriate OS in the Mouse Acceleration section; then click OK. 5. 5. 3. Virtual Media To start the Virtual Media, click on the button Virtual Media. A safety warning may pop up and ask if the application can be started. A new window will appear in which all physical drives on the computer are listed. An operating system installation can be done remotely by mapping the source file. Fig. 27 - Figure 5­2 Firmware Upgrade Step 2 LaCie 12big Rack Storage Server User Manual The Management GUI page 28 3. Start the firmware upgrade by clicking "Start Upgrade Component(s)". The progress bars will display the upgrade status of the components. 5. 6. 2. Users This section allows the management of authorized users. A maximum of five (5) users can be set, each of which can be enabled or disabled. Privilege levels are defined in the table below. Privilege Level Administrator Description All BMC commands are allowed, including configuration settings. [. . . ] DIM Code Checkpoints The Device Initialization Manager (DIM) gets control at various times during BIOS POST to initialize different system busses. Table 84 describes the main checkpoints where the DIM module is accessed. These codes are shown on the motherboard LEDs as described in section 13. 1. Introduction. Table 85 - DIM Code, High Byte, Upper Nibble Upper Nibble `X' 0 1 2 3 4 5 6 7 8 Meaning func#0, disable all devices on the bus concerned. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LACIE 12BIG RACK STORAGE SERVER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LACIE 12BIG RACK STORAGE SERVER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.