If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY RS3620. We hope that this LA CROSSE TECHNOLOGY RS3620 user guide will be useful to you.


LA CROSSE TECHNOLOGY RS3620 : Download the complete user guide (128 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY RS3620 (153 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY RS3620

Detailed instructions for use are in the User's Guide.

[. . . ] There are two cost forecasting displays screens as follows: 1) COST/MONTH = cost per month forecast (assuming normal usage) 2) COST/YEAR = cost per year forecast (assuming normal usage) Note: Press the DISPLAY button until COST/MONTH or COST/YEAR is shown in the lower display part. 26 COST SAVING CALCULATION: Once the save operation is activated the save will always be shown. When the RESET ­ DISPLAY ­ RESET key is pressed, the cost saving function is activated. The current cost/month will be stored into storage and use it as a reference value. To calculate the new cost saving result, press "LRN/SCAN" to receive new data from the Power Monitor, and then press "SAVE" to show the cost saving in different displays (percent value, cost/month, cost/year). [. . . ] In schools, educational institutions, hobby shops or co-operative workshops the use of the product must be responsibly supervised by trained personnel!Never insert needles, metal or any other objects into the mains outlet!If the product is no longer able to operate safely, it must to be put out of operation and disposed of for reason of any accidental use when the following is evident: 29 a) b) c) d) product shows obvious signs of damage. product has been stored in unfavorable conditions for a long period of time. heavy strain during product's transport may have occurred. SETTING UP: 1. About 3 seconds later, the LED indicator of the Power Monitor will light on for 2 seconds. Insert battery into the receiver, an icon "NO DEVICE" with "----" will be shown. If not, remove battery and wait for 2 minutes and then repeat this procedure. If there is already a device LRN/SCANed in one of the channels, you can clear the channel by pressing RESET ­ CH ­ RESET. 2. 3. To start the operation, it is required to connect the Remote Cost Control Receiver and the power monitor. Press LRN/SCAN key of receiver for a long time (around 2 seconds) to start the 6 seconds reception with LRN/SCANing of new channels. LCD shows "LRN" and "SCAn" during the LRN/SCANing process. 30 4. After LRN/SCANing reception is over the LCD shows "NO NEW DEVICE" in case no new device was found. 5. If a new device is found, the LCD shows the ID of the Power Monitor on the upper line and SCAn on the lower line. 31 6. 7. Or, press CH / + key to select the channel number, which should be assigned to this power monitor and then press the LRN/SCAN key for confirmation. After the right channel number is found, this Power Monitor can be LRN/SCANed instantly by pressing the LRN/SCAN key. If you don't want to select the detected Power Monitor you can press the RESET key for ignoring that Power Monitor. If more than one Power Monitor is detected, then a new ID of the newly detected Power Monitor will be displayed in the LCD. Long press the LRN/SCAN key again to restart at procedure 3 if not all the desired Power Monitors are LRN/SCANt. After LRN/SCANing reception is over a scanning will be started automatically. IMPORTANT!To update and receive any data from Power Monitor, user must press the LRN/SCAN key of receiver every time to receive transmission of Power Monitor. Note: When the receiver cannot receive data from power monitor over an hour, the "NEW DATA" will change to "OLD DATA" displays on the LCD of the receiver. Also, the "OLD DATA" will be displayed if no valid data is detected after pressing the "LRN/SCAN" key. NEW DATA OLD DATA 32 LOW BATTERY INDICATOR Low battery indicator is displayed on the LCD when the batteries require changing. · every hour the receiver automatically checks the battery status. · each time when the "LRN/SCAN" key is pressed, the receiver checks the battery status. [. . . ] This product must however not be thrown in general rubbish collection points. As stated on the gift box and labelled on the product, reading the "User manual" is highly recommended for the benefit of the user. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place. This product is only designed for use as an indicator for the average cost and average amount of electricity used for electrical appliances. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY RS3620




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY RS3620 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.