Detailed instructions for use are in the User's Guide.
[. . . ] E
4
About this manual
About the EXB-RADIAS for M3 operating manual
This EXB-RADIAS for M3 operating manual explains the RADIAS program functions and parameters that are available when the EXB-RADIAS synthesizer board is installed in the M3 music workstation/sampler. For details about basic operation of the M3 and on the functions and parameters not related to the EXB-RADIAS, refer to the M3 operation guide and parameter guide.
Conventions in the operating manual
Abbreviations in the operating manual OG, PG
When indicating reference pages, the various operating manuals of the M3 may be abbreviated in the following ways. M3 OG: M3 Operating Guide M3 PG: M3 Parameter Guide
Parameters in the LCD display screen " "
Parameters displayed in the display are enclosed in double quotation marks " ".
Symbols
,
, Note, Tips
These symbols respectively indicate a caution, a MIDIrelated explanation, a supplementary note, or a tip.
Example screen displays
The values of the parameters shown in the example screens of this manual are only for explanatory purposes, and may not necessary match the values that appear in the display of your instrument.
MIDI-related explanations
CC# is an abbreviation for Control Change Number. In explanations of MIDI messages, numbers in square brackets [ ] always indicate hexadecimal numbers.
* Company names, product names, and names of formats etc. [. . . ] OSC1 Control2 (000. . . 127/63. . . +63/01. . . 32/ LPF63. . . CNT. . . HPF63/01. . . 64l/L63. . . CNT. . . R63, Absolute): Controls a parameter appropriate for the modulation type of oscillator 1. (000. . . 127): Controls the amount of change in the oscillator 1 waveform. Unison Phase (000. . . 127): Controls the relative phase of the oscillators at note-on. Formant Offset (63. . . +63): Shifts the frequency spectrum of all formants. LPF/HPF Mix (LPF. . . CNT. . . HPF): Controls the mix balance between the low pass filter and high pass filter inside the noise generator. Balance (L001. . . C064. . . R127): Controls the left/right channel balance of the input signal. OSC2 Waveform (Saw. . . Sine, Absolute): Selects the oscillator 2 waveform. OSC2 Mod (Off/Ring. . . RingSync, Absolute): Selects the modulation type for the oscillator.
OSC2 Semitone (24. . . +24, Absolute): Controls the amount of detune (semitone units) relative to oscillator 1. OSC2 Tune (63. . . +63, Absolute): Controls the amount of detune relative to oscillator 1. OSC1 Level (000. . . 127, Absolute): Controls the output level of oscillator 1. OSC2 Level (000. . . 127, Absolute): Controls the output level of oscillator 2. Noise Level (000. . . 127, Absolute): Controls the output level of the noise generator. FilterA Type/Balance (LPF24. . . LPF12. . . HPF. . . BPF. . . THRU, Absolute): Selects the filter type for filter A. FilterA Cutoff (000. . . 127, Absolute): Controls the cutoff frequency of filter A. FilterA Resonance (000. . . 127, Absolute): Controls the resonance of filter A. FilterA EG1 Intensity (63. . . +63, Absolute): Controls the depth by which EG1 will modulate the cutoff frequency of filter A. FilterA Velocity Sens (63. . . +63, Absolute): Controls the depth by which velocity will modulate the cutoff frequency of filter A. FilterB Type (LPF. . . COMB, Absolute): Selects the filter type for filter B. FilterB Cutoff (000. . . 127, Absolute): Controls the cutoff frequency of filter B. FilterB Resonance (000. . . 127, Absolute): Controls the resonance of filter B. FilterB EG1 Intensity (63. . . +63, Absolute): Controls the depth by which EG1 will modulate the cutoff frequency of filter B. FilterB Velocity Sens (63. . . +63, Absolute): Controls the depth by which velocity will modulate the cutoff frequency of filter B. [. . . ] Before you load this data, uncheck Program in Memory Protect (M3 parameter guide p. 359). If you execute with this item still checked, a message of "Memory Protected" will appear, and the data will not be loaded. Loading RADIAS programs In the "Kind" field, select Program. If you specify Bank as the range to be loaded, select IF as the load-source data, and IF or a user bank set to the RADIAS bank type as the load-destination ("To:"). [. . . ]