User manual KONICA VIVID910

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA VIVID910. We hope that this KONICA VIVID910 user guide will be useful to you.


KONICA VIVID910 : Download the complete user guide (1746 Ko)

Manual abstract: user guide KONICA VIVID910

Detailed instructions for use are in the User's Guide.

[. . . ] NON-CONTACT 3D DIGITIZER VIVID 910/VI-910 Instruction Manual (HARDWARE) NOTE The VI-910 is model name for Europe and the VIVID 910 is model name for other countries. Please note that the VIVID 910 model name is intended only for reference with this manual. Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as result of incorrect use of the instrument. Denotes a sentence regarding safety warning or note. Read the sentence carefully to ensure safe and correct use. Notes on this Manual · Copying or reproduction of all or any part of the contents of this manual without MINOLTA's permission is strictly prohibited. · The contents of this manual are subject to change without prior notice. [. . . ] If the instrument is stored with the tripod attached, the tripod may overturn or the instrument may drop, resulting in accidents. Mounting to the Tripod 1. Mounting the Tripod base plate to the Instrument Before mounting the instrument to the tripod, mount the tripod base plate to the instrument as explained below. Memo · Five screw holes for the tripod base plate are provided on both the top and base of the instrument. In this case, remove the handle from the top of the instrument, mount the tripod base plate on the top of the instrument, then mount the handle on the base of the instrument. [Mounting the Tripod base plate] 1 2 3 Make sure that the power to the instrument is OFF, and remove the power cord. Turn the instrument slowly so that its side faces down, and place it on a flat table. Place the tripod base plate on the base (or top) of the instrument, and secure it with the five screws (supplied with the tripod base plate). * Make sure that screw washers are fitted into the dents on the base of the instrument. If you have removed the handle from the top of the instrument, attach it to the base of the instrument. 4 Tripod Base Plate 22 Notes When Using the Instrument with Tripod 2. Mounting the Instrument to the Panhead After you have attached the tripod base plate to the instrument, they need to be mounted to the recommended panhead as explained below. First, remove the accessory plate from the panhead, attach it to the instrument, then attach both to the panhead. Memo Three screw holes are provided on the back of the tripod base plate (the side with rubber feet), to allow mounting the tripod base plate to the panhead. [Attaching the Accessory Plate] 1 2 Remove the accessory plate from the panhead. Place the top of the accessory plate on the tripod base plate (attached to the instrument), and secure them with two screws (U3/8, supplied with the accessory plate). U3/8 Screw Accessory Plate [Attaching to the Panhead] 1 2 Make sure that the tripod/panhead is secured in place. Remove the rubber feet on the base plate with the use of a hexagonal wrench. Memo Remove the two rubber feet located at the rear. Note · If the instrument is to be removed from the tripod/panhead and located on the base plate, attach the rubber feet. · Store the rubber feet in a safe place after removal. 3 4 Slide the accessory plate (attached to the tripod base plate on the instrument) into the panhead. Tighten the slide fixing knob to firmly secure the accessory plate to the panhead. Memo Refer to the tripod/panhead instruction manual for details on using the accessory plate locking knob. 23 Notes When Using the Instrument with Tripod 24 Chapter 3 Operation 25 Replacing the Lens Before starting acquisition of images, the lens may need to be replaced according to the size and distance to the object. Relationship between Measurement Distance and Object With the VIVID 910, three types of lens are available: wide-angle lens, middle-angle lens and telescopic lens. A lens suitable for the size of the object and distance must be used. Memo The closer the object to the VIVID 910, the higher the measurement accuracy is. On the other hand, influences of shades produced due to roughness on the surface of the object can be reduced if the object is positioned far from the VIVID 910. Select the most suitable lens by referring to the table given below. WIDE Lens Measurement Distance Horizontal Object Size Vertical 600 367. 0 275. 2 800 486. 6 364. 9 1000 606. 2 454. 6 1200 725. 8 544. 4 2000 1204. 2 903. 2 Unit (mm) MIDDLE Lens Measurement Distance Horizontal Object Size Vertical 600 204. 7 153. 6 800 270. 6 203. 0 1000 336. 5 252. 4 1200 402. 4 301. 8 2500 830. 6 622. 9 Unit (mm) TELE Lens Measurement Distance Horizontal Object Size Vertical 600 113. 9 85. 4 800 151. 0 113. 2 1000 188. 0 141. 0 1200 225. 1 168. 8 2500 465. 9 349. 4 Unit (mm) 26 Replacing the Lens Replacing Procedure The currently installed lens can be verified by the status information. To replace the lens with another one, follow the procedure given below. · Only the lenses supplied as standard accessories with the VIVID 910 can be used. (They are not compatible with other VIVID models since they have been calibrated with the VIVID 910 only. ) · Since the VIVID 910 is a precision instrument, do not leave it without lens when replacing the lens. · If you replace the lens before saving the image data, the image data will be lost. · If dust or dirt has collected on the lens surface, remove it using a camera air blower etc. · Dust or dirt on the lens mount surface may produce incorrect measurement data. In this case, wipe the lens mount surface with a clean, dry cloth and then blow it with a camera air blower etc. [. . . ] Press any key. Insufficient amount of light There is insufficient unoccupied capacity on the memory card. Insert another memory card or press any key. 54 Error Messages Error Message (Alphabetically) MEMORY CARD IS EJECTED PRESS ANY KEY MEMORY CARD IS EJECTED RECORDING IS CANCELED PRESS ANY KEY SAME FILE NAME SYSTEM ERROR PLEASE TURN OFF Meaning The memory card has been ejected. Press any key. Action Insert a memory card into the slot. Insert a memory card into the slot. A file of the same file name already exists. If the problem still does not disappear, contact a Minolta-authorized service facility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA VIVID910




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA VIVID910 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.