User manual KONICA VIVID 910 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA VIVID 910. We hope that this KONICA VIVID 910 user guide will be useful to you.


KONICA VIVID 910 BROCHURE: Download the complete user guide (1161 Ko)

Manual abstract: user guide KONICA VIVID 910BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Production personnel use VIVID for Inspection and computer-aided dimensional testing (CAT). What's more, VIVID improves concurrent engineering by inexpensively making 3D data available throughout the enterprise. Typical Applications of the VIVID 910 The VIVID 910 is employed in a variety of industries for the following applications : Reverse Engineering (RE)/Rapid Prototyping (RP) · Generation of design CAD data from physical · · · · modelsand data for detecting interference among mechanical parts from mock-ups. Verification and comparison of competitor's products with in-house products. [. . . ] As a result, the VIVID 910 offers convenience similar to that of a digital camera, so you can operate it wherever your subject may be located. Dynamic range magnification mode Objects with very dark to very bright regions are no longer a problem. The dynamic range magnification mode reduces the need for surface processing of objects with high-contrast surfaces (surfaces with both very light and very dark areas). This feature enables you to complete a measurement in only one operation. Scan sample Dynamic range magnification mode Using Not using Benefit from the wide-ranging support provided by Konica Minolta, a leading maker of measuring instruments. The VIVID 910 incorporates the services and expertise developed by Konica Minolta in the field of industrial measuring instruments such as colorimeters and measuring instruments for displays. We ensure your satisfaction by offering a wide range of optional support programs; that includes a periodical calibration service, a training by factory certified trainers and a network of consultants and systems integrators for custom installations. Polygon Editing Tool (standard accessory) Edit scanned data with complete freedom. Our proprietary Polygon Editing Tool (PET) comes standard with the VIVID 910. PET enables you to control the VIVID 910 and easily scan, polygonize, edit, and convert the scanned data into any of several common data formats. Multiple scans can be easily registered and merged into a single watertight polygonal model. Editing functions include: fill holes; filter irregular polygons and noise; and perform smoothing. PET exports data in industry-standard formats including: DXF, STL etc. for accurate transfer to a variety of Modeling, Inspection CAD, CAM and CAT 3-D applications. In addition, a SDK (software development kit) is included to enable you to drive the VIVID 910 from your own software application. Features Data read Proprietary formats: CAM, CDM, VVD, SCN General format: STL Data conversion Converts from proprietary format to various common formats. Polygon: DXF, Wavefront, Softimage, VRML 2. 0, STL, MGF Point group: ASCII Functions Automatic data registration, data merging, smoothing, sub-sampling and curvature-based decimation, polygon checking, texture blending, and other functions Editing Rotation, transfer, elimination of point groups, and hole filling with data interpolation Remote camera operation Image capture, reference depth of field setting, dynamic range magnification mode, laser power setting, readout of camera data Display Wireframe, shading, texture mapping Data Registration and Merging Computer Requirements PC/AT-compatible workstation capable of running, Windows® 2000 or Windows® XP Operating system Windows® 2000 Professional SP4, Windows® XP Professional SP2 (x64 Edition not supported) CPU Pentium 4 or higher Memory 1024 MB minimum (2048 MB recommended) Display 1024 x 768 minimum 1280 x 1024 or higher is recommended when using Easy Align Tool for automatic marker registration. Graphics OpenGL-compatible video card(Contact us for details. ) SCSI Adaptec SCSI interface card Note: Contact us for details of tested models. [. . . ] Unlike other scanners, the VIVID has no parallax error, its "spot - on"! 111X111 to 1196X1196mm (x) 83X83 to 897X897 (y) An object Scanning field of view (x, y) VIVID 910-to-object distance (renge) 0. 6m to 2. 5m High Accuracy Measurement A high-accuracy scanner and a high-accuracy Calibration facility unit to be used for calculation of 3-D data have been developed for the VIVID 910. The 3-D reference chart traceable to the national standards has also been established to utilize the technology and algorithm that enable higher accuracy measurement. VIVID 910 System Block Diagram Poygon Editing Tool (standard accessory) Specifications PC (commercial available) PC-AT compatible machine (OS-Windows NT® / Windows® 2000 / Windows® XP) Type Measuring method Auto Focus method Light-Receiving Lens (Exchangeable) Scan Range (Depth of field) Optimal 3D measurement Range Laser class Laser Scan Method X Direction Input Range (Varies with the distance) Y Direction Input Range (Varies with the distance) Z Direction Input Range (Varies with the distance) Accuracy Input Time Transfer Time to Host Computer Ambient Lighting Condition Imaging Element Number of Output Pixels Output Format Easy Align Tool (optional) Adds functionality to the Polygon Editing Tool. · Product names in this brochure are trademarks of their respective companies. SAFETY PRECAUTIONS Read all safety and operating instructions before operating the VIVID 910. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA VIVID 910




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA VIVID 910 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.