User manual KONICA CS-200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA CS-200. We hope that this KONICA CS-200 user guide will be useful to you.


KONICA CS-200 : Download the complete user guide (3300 Ko)

You may also download the following manuals related to this product:

   KONICA CS-200 BROCHURE (8619 ko)
   KONICA CS-200 BROCHURE (3624 ko)
   KONICA CS-200 BROCHURE (3565 ko)
   KONICA CS-200 BROCHURE 2 (2527 ko)
   KONICA CS-200 BROCHURE 2 (2681 ko)
   KONICA CS-200 BROCHURE (2840 ko)
   KONICA CS-200 BROCHURE 2 (2466 ko)

Manual abstract: user guide KONICA CS-200

Detailed instructions for use are in the User's Guide.

[. . . ] CHROMA METER CS-200 Instruction Manual Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding a safety warning or note. Never disassemble the instrument. Notes on This Manual · Copying or reproduction of all or any part of the contents of this manual without KONICA MINOLTA SENCING's permission is strictly prohibited. · The contents of this manual are subject to change without prior notice. · Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. [. . . ] This has been set for [ON] by the time switching this instrument ON (|) after the shipment from factory. Setting remains even after switching OFF (O). 56 Setting BACK LIGHT 57 Setting Sleep Mode Sleep mode can be set for saving electric power consumption for the case that key has not been operated or communication has not been done for more than 30 minutes. Operation Procedure Setting SLEEP MODE 2 3 1, 7 4, 6 CH00:<DEFAULT> 5 Lv 20. 80cd/m2 x 0. 4476 y 0. 4477 <MODE>SINGLE [ ] [ 2° ] 1. Press ESC key when menu or target value setting menu appears. Measurement screen appears on LCD screen. <ANGL> 1° VIEW <SPD> AUTO <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 2. Make sure that [ ] appears on left bottom indicating this instrument has not been set for SHIFT mode. If [SFT] appears instead, it means that instrument is to operate in SHIFT mode. Press SHIFT key to cancel SHIFT mode. 3. Press MENU key three times. Menu 3/4 screen appears on LCD screen. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 4. Press ENTER key. Inversion cursor moves from [SLEEP MODE] to right to change setting for sleep mode. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 58 5. Press either or to set either for [ON] or [OFF]. If [ON] is set, this instrument operates in sleep mode when key operation or communication has not been done for more than 30 minutes. "SLEEP MODE" appears on LCD in sleep mode. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 ON Setting BREAK : [ESC] [ 2° ] SLEEP MODE SLEEP MODE If measurement button or any key is pressed, original screen appears after "PLEASE WAIT". CH02:<DEFAULT> <ANGL> 1° VIEW <SPD> AUTO Lv ------cd/m2 <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM x 0. 4476 PLEASE<MEMORY DATA> WAIT. . . y 0. 4477 ] [ 2° ] MOOO:(NO DATA) Lv -----x 0. 4155 y 0. 4242 <MODE>SINGLE [ 6. Press ENTER key. Inversion cursor returns to [SLEEP MODE] to fix setting. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 ON BREAK : [ESC] [ 2° ] 7. Press ESC key to return to measurement screen. This has been set for [ON] by the time switching this instrument ON (|) after the shipment from factory. Setting remains even after switching OFF (O). 59 CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 448 y 0. 448 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC> 200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ Setting Internal Clock This instrument is equipped with internal clock to record measurement time. Although measurement date and time are not indicated in this instrument, one can be output together with measurement value when this unit is controlled with PC. If used with either standard accessory data management software CS-S10w Standard or optional CS-S10w Professional, measurement time is to display together with measurement value. Setting DATE & TIME Operation Procedure 6 2 3 1, 9 8 4, 5 1. Press ESC key when menu or target value setting menu appears. Measurement screen appears on LCD screen. CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 4476 y 0. 4477 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 2. Make sure that [ ] appears on left bottom indicating this instrument has been set for SHIFT mode. If [SFT] appears instead, it means that instrument is to operate in SHIFT mode. Press SHIFT key to cancel SHIFT mode. 3. Press MENU key three times. Menu 3/4 screen appears on LCD screen. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 60 4. Press either or to select [DATE & TIME] and then ENTER key. < DATE & TIME > screen appears. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF Setting BREAK : [ESC] [ 2° ] 5. Press either or set arbitrary value. to key for larger number. If kept pressed, value continuously becomes small. SLEEP MODE DATE &2005Y/01M/01D TIME BUZZER 00:00:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> DATE & TIME OFF 6. Press key to move cursor to second digit position. Cursor shall not move if unsettable number has been entered. SLEEP MODE DATE &2005Y/01M/01D TIME BUZZER 00:00:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> OFF 7. Repeat the procedures from 5. If you enter month and day that do not exist in calendar, error occurs. Press ESC key to stop. SLEEP MODE DATE &2005Y/02M/01D TIME BUZZER 15:52:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> OFF 8. Press [ENTER] key. Menu 3/4 screen appears on LCD screen indicating internal clock has been set. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 9. Press ESC key to return to measurement screen. Internal clock adjustment has been completed before shipment form factory. CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 448 y 0. 448 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC> 200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 61 62 Measurement Preparation 63 Calibration Calibration Channel There are 21 calibration channels from CH00 to CH20. (1) Correction coefficient of user calibration (2) Target color (3) CH ID name These are commonly used among each measurement mode of Lvxy, Lvu'v', LvTuv, XYZ, and dominant wavelength in one channel. CH00 is for measurement based upon KONICA MINOLTA SENSING's calibration standard. Its calibration correction coefficient has been set and is unchangeable. To switch calibration channel, press either or key in SHIFT mode to switch one appearing on LCD screen. CH ID name is shown on LCD screen together with calibration channel. Measurement Preparation 64 User Calibration User calibration indicates to set user's original correction coefficients in calibration channel by setting calibration value (For Lv, x, and y or Lv, u' and v' or X, Y and Z) in this instrument. Displayed and output values for every measurement are values corrected with this correction coefficient unexceptionally. (1) Difference in instrument readings due to difference between CIE 1931 color-matching functions and spectral sensitivity. (2) Difference in instrument readings between units if multiple numbers of this unit are used. Accurate measurement can be performed at luminance and chromaticity around calibration light source. Measurement Preparation If you obtain calibration value by measuring a calibration light source with a prototype standard, set the prototype standard and CS-200 in the same position and angle as for the calibration light source and measure the same area. If measurement conditions with the prototype standard and with CS-200 are different, you fail to perform correct caliblation. [. . . ] When an object whose luminance has changed greatly from the previous measurement is measured, measurement may be interrupted to set the optimum gain for measurement and then remeasurement will be performed; during remeasurement, the remaining measurement time display is frozen. Switch to remote mode by sending connection command from PC to this instrument. Use standard accessory data management software CS-S10w Standard. Page to Refer 9 Display of Is object to measure the remaining stable?measurement time freezes, and measurement is not completed for the set measurement time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CS-200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CS-200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.