User manual KONICA CM-700D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA CM-700D. We hope that this KONICA CM-700D user guide will be useful to you.


KONICA CM-700D : Download the complete user guide (15528 Ko)

You may also download the following manuals related to this product:

   KONICA CM-700D BROCHURE (345 ko)
   KONICA CM-700D BROCHURE (344 ko)
   KONICA CM-700D BROCHURE (344 ko)
   KONICA CM-700D BROCHURE 2 (1643 ko)
   KONICA CM-700D BROCHURE 2 (1632 ko)
   KONICA CM-700D BROCHURE 2 (1620 ko)
   KONICA CM-700D BROCHURE (386 ko)
   KONICA CM-700D BROCHURE 2 (1620 ko)

Manual abstract: user guide KONICA CM-700D

Detailed instructions for use are in the User's Guide.

[. . . ] Spectrophotometer CM-700d/600d E Instruction Manual Es Manual de instrucciones Notes on this Manual · Copying or reproduction of all or part of the contents of this manual without KONICA MINOLTA SENSING's permission is strictly prohibited. · The contents of this manual are subject to change without prior notice. · Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact a KONICA MINOLTA SENSING-authorized service facility. [. . . ] Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-37 Condition Setting Color Index Select the index (WI, YI, etc. ) to be used. [Setting Procedure] Start the procedure from the <Disp. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Color Index" and then press the [SAVE/SEL] button. The <Color Index> screen is displayed. 2 Use the or button of the cross key to move the cursor to the desired item. Settings None WI (E313-73): Whiteness index (ASTM E313-73) WI (E313-96): Whiteness index (ASTM E313-96) YI (E313-73): Yellowness index (ASTM E313-73) YI (D1925): Yellowness index (ASTM D1925) ISO Bright. : ISO Brightness 8° Gloss: The gloss value calculated with the specular reflection in the direction of . This value can be used 8 for relative management of glossiness. Memo 8° Gloss will be displayed when "I+E" for specular component mode is selected. 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Disp. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-38 Condition Setting Observer Select the observer angle: 2° or 10°. [Setting Procedure] Start the procedure from the <Disp. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Observer" and then press the [SAVE/SEL] button. The <Observer> screen is displayed. 2 Use the or button of the cross key to move the cursor to the desired item. Settings 2°: 2° observer (CIE1931) 10°: 10° observer (CIE1964) 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Disp. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-39 Condition Setting Illuminant 1 Select the illuminant used to measure colorimetric data. [Setting Procedure] Start the procedure from the <Disp. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Illuminant 1" and then press the [SAVE/SEL] button. The <Illuminant 1> screen is displayed. 2 Use the or button of the cross key to move the cursor to the desired item. Settings A: Standard illuminant A (Incandescent lamp, Color temperature: 2856K) C: Illuminant C (Daylight, The relative value of the spectral distribution in the ultraviolet region is small; Color temperature: 6774K) D50:Illuminant D50 (Daylight, Color temperature: 5003K) D65:Standard illuminant D65 (Daylight, Color temperature: 6504K) F2: Cool white (fluorescent lamp) F6: Cool white (fluorescent lamp) F7: Color rendering A daylight white (fluorescent lamp) F8: Color rendering AAA natural white (fluorescent lamp) F10:3-band type natural white (fluorescent lamp) F11: 3-band type cool white (fluorescent lamp) F12:3-band type warm white (fluorescent lamp) 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Disp. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-40 Condition Setting Illuminant 2 Select the secondary illuminant used for MI (metamerism index) calculation, etc. [Setting Procedure] Start the procedure from the <Disp. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Illuminant 2" and then press the [SAVE/SEL] button. The <Illuminant 2> screen is displayed. 2 Use the or button of the cross key to move the cursor to the desired item. Settings The setting values are the same as those for "Illuminant 1" and "None". 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Disp. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-41 Condition Setting Setting the Measurement Conditions To set measurement conditions, select "Meas. You can select or specify the following four items as the measurement conditions: · Mode: Select the specular component mode. · Wait Time: Specify the delay between the press of the measuring button and the flash of the lamp. · Auto Ave. : Specify the number of measurements for auto averaging. [. . . ] While this message is displayed, the buttons of the instrument are disabled. You can, however, send a command from the PC to the instrument to set it to the measuring button enabled mode, so that you can start measurement by pressing the measuring button of the instrument. In this case, the measured data is transferred to the PC and is not stored in the memory of the instrument. If you want to control the instrument from a PC, you need software that allows the connection and operation of the instrument. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-700D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-700D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.