User manual KONICA CM-508C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA CM-508C. We hope that this KONICA CM-508C user guide will be useful to you.


KONICA CM-508C : Download the complete user guide (1263 Ko)

Manual abstract: user guide KONICA CM-508C

Detailed instructions for use are in the User's Guide.

[. . . ] Unlike conventional spectrophotometers, correlation of the measurement results with visual evaluation of such subjects can be achieved. The ring-shaped illumination ensures stable measurement without being affected by the orientation (rotational deviation) of the instrument. [. . . ] Measurement is stable even for curved surfaces, such as automotive components. Not only flat surfaces but also curved surfaces can be measured stably with the large measurement area, the two extension feet and the optional grip attached to the instrument. Grip CM-A42 (optional) The graph display function enables easy color judgment even on production sites without using a personal computer. Tolerance (allowable range) can be set for each target data. L*C*H*E00 display example L* Vertical full-scale value ± 0 line Color difference tolerance setting example: E00=0. 5 C* H* E00 25º 45º 75º Line graph display Color difference display PASS/FAIL display Original development Evaluation equation suitable for measurements of metallic/pearl coating correlates well with visual evaluation. With the conventional E*ab equation, the values in the highlight direction (25º) become larger and do not correlated well with the results of visual evaluation. With the CM-512m3, the E00 (CIEDE2000) equation is used with parameters fine-tuned based on proprietary knowhow to provide measurement data for metallic/pearl coatings which correlate well with visual evaluation. Measurement button Extension feet Multi-angle method (Ring illumination from three angles / Light reception in one direction) Illumination: 25º, 45º, 75º Light reception: 0º The measurement sample is illuminated from three angles and the reflection in one direction is received. Metallic/pearl colors may result in great differences in color appearance depending on the observation angle. Like visual evaluation, the multi-angle method obtains measured data by applying illumination from three different angles. 400 measurements at 10-second intervals (when a dark color is measured with alkaline batteries at 23ºC) ø12 mm /ø20 mm System Configuration Spectrophotometer CM-512m3 Four AA-size batteries Worldwide (except Europe): AC adapter AC-A21 Europe only: AC adapter AC-A12 (Not evaluated by UL. ) Grip CM-A42 Accessory Switch CM-A23 Spectral reflectance: Within 0. 3% (standard deviation) Chromaticity value: Within E*ab 0. 05 (standard deviation) (When a white calibration plate is measured 30 times at 11-second intervals after white calibration) ; When AC adapter is used Interface RS-232C Terminal: D-Sub 9-pin (female)/IrDA Display Dot-matrix reflective LCD with 21 characters x 7 lines (128 x 56 dots) With contrast control slide Displayed data Colorimetric data: L*a*b*, L*C*h Color difference data: (L*a*b*), (L*C*H*), E*ab, CMC(l:c), E00(CIEDE2000) Other data display: FF value, line graph, temperature Storable data sets 440 data sets max. (total of sample and target data) Illuminant Light source: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 /Observer conditions Observer: 2º, 10º Temperature detection Detector: Thermopile Wavelength: 8 to 13 µm Measurement/display range: -10º to 80ºC (0. 1ºC increments) Measurement diameter: ø20 mm Measurement rating: 0º to 50ºC: ± 2. 5ºC ± 1digit (when an object of 0. 93 emissivity is measured at ambient temperatures of 18º to 28ºC) Operating temperature 0ºC to 40ºC, relative humidity 85% or less (at 35ºC) with no condensation /humidity range (*1) Storage temperature -20ºC to 45ºC, relative humidity 85% or less (at 35ºC) with no condensation /humidity range Power Four AA-size batteries or special AC adapter Size 115 (W) x 257 (H) x 164 (D) mm Weight Approx. 1. 4 kg (without batteries) *1 Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation Worldwide (except Europe): RS-232C Cable IF-A12 (2 m) Zero Calibration Box CM-A32 Europe only: RS-232C Cable IF-A19 (2 m) White Calibration Cap CM-A87 Hand Strap CM-A24 Worldwide (except Europe): RS-232C Cable IF-A13 (5 m) Europe only: RS-232C Cable IF-A20 (5 m) Connecting Cable Hard Case CM-A64 Personal computer (commercial product) Printer (commercial product) Color Data Software CM-S100w Standard accessories Optional accessories Color Data Software CM-S100w (optional) Supports Windows® 2000/XP Outer dimensions (Unit: mm) 115 164 257 48 40 43 100 By using the Color Data Software CM-S100w (optional), you can display the data for the 3 different illumination angles simultaneously. Or, you can create a line graph that visually shows the angle characteristics specific to a multi-angle spectrophotometer. · Specifications and drawings are subject to change without prior notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. [. . . ] Or, you can create a line graph that visually shows the angle characteristics specific to a multi-angle spectrophotometer. · Specifications and drawings are subject to change without prior notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-508C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-508C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.