User manual KENWOOD TS-870

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KENWOOD TS-870. We hope that this KENWOOD TS-870 user guide will be useful to you.


KENWOOD TS-870 : Download the complete user guide (1354 Ko)

Manual abstract: user guide KENWOOD TS-870

Detailed instructions for use are in the User's Guide.

[. . . ] The parallel method is faster but more complicated, while the serial method is slower and requires less complicated equipment. Serial data transmission uses time-division methods over a single line. Using a single line also offers the advantage of reducing the number of errors due to line noise. Only 3 lines are required theoretically for control of the transceiver via the computer: · Transmit data · Receive data · Ground From a practical standpoint, it is also necessary to incorporate some means of controlling when this data transfer will occur. [. . . ] EX00000003; (Display brightness level 3). E Answer 11 P5 X 12 ; 6 PC CONTROL COMMAND Menu No. 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 EX command parameter P5 Function 0 Display brightness Key illumination Auto Mode operation Tuning control adjustment rate Tuning with Tuning control in FM mode Rounds off VFO frequencies changed by using the MULTI control 9 kHz frequency step size for the MULTI control in AM mode on the AM broadcast band Tunable (ON) or fixed (OFF) memory channel frequencies Program scan partially slowed Slow down frequency range for the Program scan Program scan hold Scan resume method Beep output level TX sidetone volume VGS-1 message playback volume VGS-1 announcement volume VGS-1 announcement speed Use CW IF filter for SSB reception DSP RX equalizer DSP TX equalizer DSP TX filter bandwidth for SSB or AM Fine transmission power tuning Time-out timer Transverter frequency display Output power adjustment for Transverter TX hold when AT completes the tuning In-line AT while receiving Control method for the external AT Linear amplifier control delay for HF band Linear amplifier control delay for 50 MHz band Constant recording Repeat the playback Interval time for repeating the playback Keying priority over playback CW RX pitch/ TX sidetone frequency CW keying dot, dash weight ratio Reverse CW keying auto weight ratio Bug key function OFF OFF OFF 25 0 OFF OFF OFF OFF OFF 100 OFF to OFF OFF OFF OFF OFF OFF OFF OFF 2. 0 OFF OFF OFF OFF OFF OFF At1 OFF OFF OFF OFF 0 OFF 40 0 A UT O OFF OFF 1 1 ON ON 500 ON ON ON ON ON 200 ON co 1 1 1 1 1 ON Hb1 Hb1 2. 4 ON 3 ON ON ON ON At2 1 1 ON ON 1 ON 450 2. 5 ON ON 500 2. 6 550 2. 7 600 2. 8 650 2. 9 700 3. 0 750 3. 1 800 3. 2 850 3. 3 ~ 1000 (in steps of 50) ~ 4. 0 (in steps of 0. 1) 2 3 4 5 6 7 8 9 ~ 60 (in steps of 1 s) 2 2 3 3 5 10 20 30 (minutes) Hb2 Hb2 FP FP bb1 bb1 bb2 bb2 c c U U 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 9 9 9 300 400 500 (Hz) 1000 (Hz) 2 2 3 3 4 4 5 6 7 8 9 Over 7 PC CONTROL COMMAND Menu No. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 F 1 T 2 Parameters: P1 0: VFO A 1: VFO B 2: M. CH When P1=2 is selected for the FR command, the FT command becomes invalid. Read F 1 T 2 Answer F T FW Set Selects or reads the DSP filtering bandwidth. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 P1 7 ; 8 9 10 4 P1 4 5 P1 5 6 P1 6 7 ; 7 8 9 10 8 9 10 F 1 W 2 Parameters: P1 0000 ~ 9999 (in Hz) CW: 0050, 0080, 0100, 0150, 0200, 0300, 0400, 0500, 0600, 1000, 2000 FSK: 0250, 0500, 1000, 1500 SSB/FM/AM: 0000=Normal, 0001=NAR, 0002=NAR2 Use the SL or SH command to change the slope tune filter frequencies. Read F 1 W 2 Answer F W GT Se t Selects or reads the AGC constant status. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 ; 7 8 9 10 4 P1 4 5 P1 5 6 ; 6 7 8 9 10 7 8 9 10 G 1 T 2 Parameters: P1 000: OFF 001: Fast 002: Slow The GT command cannot be used in FM mode. The transceiver responds with 3 spaces when the GT command is used in FM mode. Read G 1 T 2 Answer G T ID Se t Reads the transceiver ID number. 1 2 3 4 5 6 7 8 9 10 Parameters: P1 020: TS-480 1 Read 2 3 ; 3 P1 4 5 6 7 8 9 10 I 1 D 2 4 P1 5 P1 6 ; 7 8 9 10 Answer I D 10 PC CONTROL COMMAND IF Set Retrieves the transceiver status. 1 2 3 4 5 6 7 8 9 1 Read 2 3 ; 3 P1 13 P1 23 P3 33 P12 4 5 6 7 8 9 I 1 F 2 4 P1 14 P2 24 P4 34 P13 5 P1 15 P2 25 P5 35 P14 6 P1 16 P2 26 P6 36 P14 7 P1 17 P2 27 P7 37 P15 8 P1 18 P2 28 P7 38 ; 9 P1 19 P3 29 P8 39 I 11 P1 Answer 21 P3 31 P10 F 12 P1 22 P3 32 P11 Parameters: P1 Specify the frequency in Hz (11-digit). P3 RIT/ XIT frequency ±9990 in Hz 10 P4 0: RIT OFF, 1: RIT ON P5 0: XIT OFF, 1: XIT ON P6: Always 0 for the TS-480 (Memory channel bank number). P12 0: Simplex operation, 1: Split operation P9 P13 0: OFF, 1: TONE, 2: CTCSS 40 P14 Tone number (00 ~ 42). P15 A space character for the TS-480. Parameters: P1 + or " " (a space): Plus shift ­: Minus shift P2 0000 ~ 1100 IS Se t Sets and reads the IF SHIFT function status. 1 2 3 P1 3 ; 3 P1 4 P2 5 P2 6 P2 7 P2 8 ; 9 10 4 P2 4 5 P2 5 6 P2 6 7 P2 7 8 ; 8 9 10 9 10 I 1 S 2 Read I 1 S 2 Answer I S KS Se t Sets and reads the CW electric keyer's keying speed. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 N 1 R 2 Parameters: P1 0: Noise Reduction (NR) OFF 1: Noise Reduction 1 (NR1) ON 2: Noise Reduction 2 (NR2) ON Read N 1 R 2 Answer N R 14 PC CONTROL COMMAND OP Set Reads the IF filter availability. 1 2 3 4 5 6 7 8 9 10 1 R ead 2 3 ; 3 P1 4 5 6 7 8 9 10 O 1 P 2 4 P2 5 P3 6 ; 7 8 9 10 Parameters: P1 0: YF-107SN (1. 8 kHz) is not installed. 1: YF-107CN (270 Hz) is installed. Answer O P PA Set Sets or reads the pre-amplifier function status. 1 2 3 P1 3 ; 3 P1 4 P2 5 ; 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 P 1 A 2 Parameters: P1 0: Pre-amplifier OFF 1: Pre-amplifier ON P2 (Answer only) 0: Always 0 for the TS-480 Read P 1 A 2 Answer P A PB Set Sets or reads the VGS-1 or electric keyer playback status. 1 2 3 P1 3 ; 3 P2 4 P3 5 P4 6 ; 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 P 1 B 2 Read P 1 B 2 Answer P B Parameters: P1 0: Stop playing back a message. 1: Playback CH1 2: Playback CH2 3: Playback CH3 P2 ~ P4 Playback queing buffer status. 0: Inactive 1: Playback CH1 2: Playback CH2 3: Playback CH3 Parameters: TS-870 P1 005 ~ 200 (in steps of 1) for SSB/ CW/ FM/ FSK mode 005 ~ 050 (in steps of 1) for AM mode TS-480SAT P1 005 ~ 100 (in steps of 1) for SSB/ CW/ FM/ FSK mode 005 ~ 025 (in steps of 1) for AM mode PC S et Sets or reads the output power. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 ; 7 8 9 10 4 P1 4 5 P1 5 6 ; 6 7 8 9 10 7 8 9 10 P 1 C 2 Read P 1 C 2 Answer P C PL Set Sets and reads the Speech Processor input/ output level. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 P2 7 P2 8 P2 9 ; 10 4 P1 4 5 P1 5 6 P2 6 7 P2 7 8 P2 8 9 ; 9 10 10 P 1 L 2 Parameters: P1 Input level: 000 (min. ) ~ 100 (max. ) P2 Output level: 000 (min. ) ~ 100 (max. ) Read P 1 L 2 Answer P L 15 PC CONTROL COMMAND PR Se t Sets or reads the Speech Processor function ON/ OFF. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 Parameters: P1 0: Speech Processor OFF 1: Speech Processor ON P 1 R 2 Read P 1 R 2 Answer P R PS Se t Sets or reads the Power ON/ OFF status. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 P 1 S 2 Parameters: P1 0: Power OFF (The transceiver's CPU is in active mode. ) 1: Power ON 9: Power OFF (The transceiver's CPU is in sleep mode. ) When the transceiver is turned OFF and P1=9, a dummy data must be sent to the TS-480 to wake up the CPU. [. . . ] 20 10 S 1 S 2 S Answer 11 P3 S 12 P3 ST Set Sets or reads the MULTI control frequency steps. 1 2 3 P1 3 ; 3 P1 4 P1 5 ; 6 7 8 9 10 4 P1 4 5 ; 5 6 7 8 9 10 6 7 8 9 10 S 1 T 2 Read S 1 T 2 Parameters: P1 SSB/ CW/ FSK mode: 00 ~ 04 00: 0. 5 kHz, 01: 1 kHz, 02: 2. 5 kHz, 03: 5 kHz, 04: 10 kHz AM/ FM mode: 00 ~ 09 00: 5 kHz, 01: 6. 25 kHz, 02: 10 kHz, 03: 12. 5 kHz, 04: 15 kHz, 05: 20 kHz, 06: 25 kHz, 07: 30 kHz, 08: 50 kHz, 09: 100 kHz Answer S T SU Sets or reads the Program Scan (VGROUP)/ Memory Group (MGROUP) selection status. 1 2 3 P1 13 P11 3 P1 3 P1 13 P11 4 P2 14 ; 4 ; 4 P2 14 ; 5 P3 15 6 P4 16 7 P5 17 8 P6 18 9 P7 19 5 6 7 8 9 5 P3 15 6 P4 16 7 P5 17 8 P6 18 9 P7 19 S Se t 11 P9 1 Read U 12 P10 2 S 1 U 2 S Answer 11 P9 U 12 P10 Parameters: P1 0: Program Scan Group (VGROUP) 1: Memory Group (MGROUP) 10 P2 Group 0. 0: Unselected, 1 ~ 9: Selected 20 PC CONTROL COMMAND SV Se t Execute the Memory Transfer function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENWOOD TS-870




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KENWOOD TS-870 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.