User manual KENWOOD DM-9090

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KENWOOD DM-9090. We hope that this KENWOOD DM-9090 user guide will be useful to you.


KENWOOD DM-9090 : Download the complete user guide (1298 Ko)

Manual abstract: user guide KENWOOD DM-9090

Detailed instructions for use are in the User's Guide.

[. . . ] MINIDISC RECORDER DM-9090 INSTRUCTION MANUAL B60-3491-00 JA (T) MC 98/12 11 10 9 8 7 6 5 4 3 2 1 97/12 11 10 9 8 7 Introduction DM-9090 (En) 2 Before applying power Units are designed for operation as follows. Caution : Read this section carefully to ensure safe operation. U. K. and Europe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC 230 V only For the United Kingdom Factory fitted moulded mains plug 1. The fuse cover must be refitted when replacing the fuse in the moulded plug. [. . . ] 1 Track mode : PGM goes off 2 Program mode : PGM lights up "PGM" lights up OVER (-dB) ANALOG 1 MONITOR DIGITAL 2 3 2 Select the desired tracks in the desired order. ABC DEF 32kHz 44. 1kHz 48kHz 1 GH I 2 JKL 3 MNO 4 PRS 5 TUV 6 WXY CHARA. P. MODE ÷ All of the programmed tracks will be repeated. ÷ In case only one track is programmed, only that track will be repeated. 7 &( )-/ 8 QZ 9 ' , : ?! +100 0 +10 "REPEAT" lights up 2 Repeat the procedure 2. REPEAT L SEARCH R 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 MONITOR DIGITAL 2 3 3 Enter the repeat mode. REPEAT PGM 32kHz 44. 1kHz 48kHz 4 Start playback. 3 To stop repeated playback Press the REPEAT key again. ÷ The "REPEAT" indicator goes off and the playback following the current mode (PROGRAM) of the MD player starts. To repeat the entire disc 1 Enter the track mode. CHARA. P. MODE Each press switches the mode. 1 Track mode : PGM goes off 2 Program mode : PGM lights up "REPEAT" lights up 2 Enter the repeat mode. REPEAT REPEAT PGM SEARCH L R 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 MONITOR DIGITAL 2 3 32kHz 44. 1kHz 48kHz 3 Start playback. 3 To stop repeated playback Press the REPEAT key again. ÷ The "REPEAT" indicator goes off and the playback following the current mode (TRACK) of the MD player starts. Recording-related keys DM-9090 (En) AUTO/MANUAL key This key is used to select whether track numbers are to be marked automatically during recording or they are to be marked manually during or after recording. The track numbers can be used to locate the beginning of a track during playback or programming tracks. Select before starting recording. AUTO/ MANUAL 23 AUTO If a no-sound input has lasted for 2 seconds during recording, the track number will be incremented automatically by "1". When recording music containing a continuous section with a very low level, for example when recording classic music, the track number may be incremented by "1" after such a section. It is recommended to use the MANUAL mode when recording such a kind of music. During digital recording of CD, the track number is incremented automatically by "1" according to the data contained in the digital information. When the CD track number is increased during manual search of a CD, the track number recorded on the MD may sometimes fail to be incremented. A nosound track may sometimes created at the moment the played CD stops. L PGM SEARCH R 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 MONITOR MANUAL DIGITAL 2 3 32kHz 44. 1kHz 48kHz MANUAL Extinguished in "AUTO" mode, lit in "MANUAL" mode. With this setting, the MD track number is not incremented automatically during recording. Track numbers can be marked either during editing (by pressing the EDIT key) or after recording (by executing the TRACK DIVIDE operation fl). This setting is convenient when recording a CD which has been recorded in live or which contains very low-level sound such as a classical music CD. MONITOR key Press to monitor the sound being input from the source while the unit is in stop mode. When the REC INPUT is DIGITAL, the sampling rate (48 kHz, 44. 1 kHz, 32 kHz) of the input digital signal can be displayed by pressing this key. Press in stop mode. Main unit MONITOR Remote control unit L 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 MONITOR DIGITAL 2 3 MONITOR PGM SEARCH R 32kHz 44. 1kHz 48kHz "MONITOR" litghts up Recording-related keys DM-9090 (En) The recording-related settings can be adjusted precisely by selecting the proper display modes. 24 REC MODE key Selecting the setting adjustment mode 1 Switch the REC MODE on. REC MODE /CHARA. Each press switches the mode. 1 REC MODE : off 2 REC MODE : on ("D. REC LEVEL?" displayed. ) 2 Select the setting adjustment mode. 4 JOG DIAL ¢ DOWN PUSH SET UP The modes are switched by rotating the JOG DIAL. : Setting of the time for detecting a no-sound blank section during automatic track number marking. : Setting of the level for detecting a nonsound blank section during automatic track number marking. : Setting of the UTOC writing after recording. 3 Set the selection (by pressing the JOG DIAL). 4 JOG DIAL ¢ DOWN PUSH SET UP ÷ The "D. REC LEVEL" and "FADE TIME" settings are not used during analog source recording. 4 Adjust the setting value. 4 JOG DIAL ¢ ÷ Step 4 consists of adjusting the setting of the "Setting adjustment mode" selected in step 2. DOWN PUSH SET UP To change another setting, press the JOG DIAL (PUSH SET knob). (This returns to step 2 above. ) To end the setting adjustment, press the REC MODE/CHARA. key again. Recording-related keys DM-9090 (En) When "D. REC LEVEL?" is selected (Valid during digital recording) Pressing the SET key while "D. REC LEVEL?" is displayed initiates the initial display for the digital recording level adjustment. The recording level of the currently selected digital input can be varied by operating the skip up/down keys. The initial setting is "DIN[1] D 0 dB", which can be set in the level range between -` and +12 dB. Initial display L PGM SEARCH R 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 DIGITAL 2 3 25 32kHz DIN[1] Adjusted value display L PGM SEARCH R * L 0dB 12 9 7 5 3 1 0 MONITOR 44. 1kHz 48kHz 40 30 21 18 15 12 9 7 5 3 1 0 OVER (-dB) ANALOG 1 DIGITAL 2 3 PGM SEARCH 40 30 21 18 15 OVER (-dB) ANALOG 1 DIGITAL 2 3 R 32kHz 32kHz DIN[1] - dB MONITOR 44. 1kHz 48kHz DIN[1] 12 dB MONITOR 44. 1kHz 48kHz When "AUTO TIME?" is displayed (Valid during analog recording) Pressing the SET key while "AUTO TIME?" is displayed initiates the initial display for the no-sound blank detection time adjustment for automatic track number marking. The time after which a no-sound blank is detected can be varied by operating the skip up/down keys. [. . . ] Semiconductor laser Recording method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field modulation overwrite method Audio compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATRAC (Adaptive TRansform Acoustic Coding) Playing rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 rpm ~ 900 rpm (CLV) [D/A conversion] D/A conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENWOOD DM-9090




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KENWOOD DM-9090 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.