User manual KENMORE 625.385560

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KENMORE 625.385560. We hope that this KENMORE 625.385560 user guide will be useful to you.


KENMORE 625.385560 : Download the complete user guide (4022 Ko)

Manual abstract: user guide KENMORE 625.385560

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL E L I T E Reverse Osmosis System MODEL NO. 625. 385560 UltraFilter 650 Caution: Read and follow all safety rules and operating instructions before first use of this product. Questions ?Visit www. KenmoreWater. com or call toll free 1-800-426-9345 (M - F, 7AM - 8 PM CST) Repair or Parts ?Call toll free 1-800-366-7278 See back cover for other Sears service numbers. [. . . ] Continue pushing until the tube bottoms out against the back of the fitting. When a 1/4" tube is fully engaged, 11/16" of the tube has entered the fitting. When a 3/8" tube is fully engaged, 3/4" of the tube has entered the fitting. If using tubing other than tubing supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. See Figure 20. Push In Fitting Tube Cut tubing square with end of tubing round, smooth, with no cuts, nicks or flat spots. Tube Correctly Cut Figure 16 O-Ring Collet Tube Partially Engaged With Fitting Figure 17 O-Ring Collet Tube Fully Engaged With Fitting Figure 18 Collet (Depress to Remove Tubing) Fitting O-Ring Seal Collet Tubing Collet and O-Ring Disconnect Tubing Figure 20 Figure 19 Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com 14 Step 6 - Connect Tubes 3/8" black tubing 1/4" red tubing water supply fitting 3/8" blue tubing NOTE: Tubing lengths should allow access to the back of the assembly for servicing. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of Massachusetts before proceeding with the installation. HOT COLD sink p-trap 1/4" green tubing 3/8" yellow tubing tubing connector Tube Connections Figure 21 CONNECT YELLOW TUBE TO STORAGE TANK 1. Run the other end of the yellow tube to the fitting on top of the storage tank. This will occur in the sanitizing step. CONNECT BLUE TUBE TO REVERSE OSMOSIS ASSEMBLY The blue tube connection was completed in the faucet assembly steps. CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1. The other end needs to be attached to the black collet on the sink drain adapter. Cut this tube as needed to route in as straight of a run as possible, without loops, dips, low spots or kinks. Pull on the tube to be sure it is held firmly in the fitting. CONNECT GREEN TUBE TO COLD WATER SUPPLY PIPE 1. Run one end of the 1/4" green tube to the fitting on the water supply pipe. This is a compression fitting. CONNECT RED TUBE TO REVERSE OSMOSIS FAUCET The red tube connection was completed in the faucet assembly steps. Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com 15 Step 7 - Sanitize, Test and Purge System SANITIZE THE SYSTEM Sanitizing is recommended immediately after installation of the Reverse Osmosis system. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system. Locate the eyedropper that is included in package and common household bleach (5. 25%). Handle bleach according to bleach manufacturer's recommendations. Sanitizing the system will be completed during the pressure test and purging steps on the following page. NOTE: The bleach must be removed from the system before drinking the water. Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com 16 Step 7 - Sanitize, Test and Purge System PRESSURE TEST THE SYSTEM NOTE: Complete the sanitizing procedures on the preceding page before pressure testing. [. . . ] If rate does not increase, replace the postfilter cartridge and Reverse Osmosis membrane cartridge. See page 20. Problem: System makes lower amount of product water than usual. Cause: Storage tank air-charge less than 5-7 psi. Correction: Open Reverse Osmosis faucet and drain tank until flow slows to a drip. Close faucet to refill the tank. Problem: High total dissolved solids (TDS) in product water Cause: Water supply to the Reverse Osmosis sys- Correction: tem not within specifications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENMORE 625.385560




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KENMORE 625.385560 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.