User manual KENMORE 625.381560

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KENMORE 625.381560. We hope that this KENMORE 625.381560 user guide will be useful to you.


KENMORE 625.381560 : Download the complete user guide (2563 Ko)

Manual abstract: user guide KENMORE 625.381560

Detailed instructions for use are in the User's Guide.

[. . . ] 625. 381560 UltraFilter 450 Caution: Read and follow all safety rules and operating instructions before first use of this product. Questions ?Visit www. KenmoreWater. com or call toll free 1-800-426-9345 (M - F, 7AM - 8 PM CST) Repair or Parts ?Call toll free 1-800-366-7278 See back cover for other Sears service numbers. SAVE THIS MANUAL · Warranty · Installation · How It Works · Care Of · Specifications · Repair Parts System Tested and Certified by NSF International against NSF/ANSI Standard 42 and 58. [. . . ] When a 1/4" tube is fully engaged, 11/16" of the tube has entered the fitting. When a 3/8" tube is fully engaged, 3/4" of the tube has entered the fitting. If using tubing other than tubing supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. See Figure 20. Push In Fitting Tube Cut tubing square with end of tubing round, smooth, with no cuts, nicks or flat spots. Tube Correctly Cut Figure 16 O-Ring Collet Tube Partially Engaged With Fitting Figure 17 O-Ring Collet Tube Fully Engaged With Fitting Figure 18 Collet (Depress to Remove Tubing) Fitting O-Ring Seal Collet Tubing Collet and O-Ring Disconnect Tubing Figure 20 Figure 19 Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com 14 Step 6 - Connect Tubes NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of Massachusetts before proceeding with the installation. "b lu water supply fitting 1/4" tu 1/4" green 3/8" black tubing 3/8 red HOT COLD et ub in n tubi g sink p-trap g 3/8" yellow tubing tubing connector bing NOTE: Tube colors match Collet colors Tube Connections Figure 21 CONNECT YELLOW TUBE TO STORAGE TANK 1. Run the other end of the yellow tube to the fitting on top of the storage tank. This will occur in the sanitizing step. CONNECT BLUE TUBE TO REVERSE OSMOSIS ASSEMBLY 1. Run the other end of the 3/8" blue tube to the blue collet on the right side of the Reverse Osmosis filter assembly. Pull on the tube to be sure it's held firmly in the fitting. CONNECT GREEN TUBE TO COLD WATER SUPPLY PIPE 1. Run one end of the 1/4" green tube to the fitting on the water supply pipe. Run the other end of the green tube to green collet to the fitting on the left side of the Reverse Osmosis filter assembly. Pull on the tube to be sure it is held firmly in the fitting. CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1. The other end needs to be attached to the black collet on the sink drain adapter. Cut this tube as needed to route in as straight of a run as possible, without loops, dips, low spots or kinks. Pull on the tube to be sure it is held firmly in the fitting. CONNECT RED TUBE TO REVERSE OSMOSIS FAUCET The red tube connection was completed in the faucet assembly steps. Questions?Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater. com 15 Step 7 - Sanitize, Test and Purge System SANITIZE THE SYSTEM Sanitizing is recommended immediately after installation of the Reverse Osmosis system. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system. Locate the eyedropper that is included in package and common household bleach (5. 25%). Handle bleach according to bleach manufacturer's recommendations. [. . . ] Correction: Increase water pressure, precondition the water, etc. , as needed to conform before doing maintenance on the Reverse Osmosis system. If rate does not increase, replace the postfilter cartridge and Reverse Osmosis membrane cartridge. See page 20. Problem: System makes lower amount of product water than usual. Cause: Storage tank air-charge less than 5-7 psi. Correction: Open Reverse Osmosis faucet and drain tank until flow slows to a drip. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENMORE 625.381560




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KENMORE 625.381560 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.