User manual KANTECH KT-300
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KANTECH KT-300. We hope that this KANTECH KT-300 user guide will be useful to you.
Manual abstract: user guide KANTECH KT-300
Detailed instructions for use are in the User's Guide.
[. . . ] KT-300
Door Controller
Installation Manual
DN1315-0707
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Copyright Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Components Required to Install KT-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
KT-300 Compliance Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FCC & IC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CE Compliance Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 UL Compliance Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Otherwise, reduce the communication speed to a minimum to avoid data loss. From 60m to 1. 2 km (200 to 4, 000 feet) If the master controller is located more than 60m (200 feet), an optional VC-485 multi-function communication interface must be used. It can also be used when running a communication cable in areas unusually high in electrical noise.
NOTE: The host computer is used to program the KT-300
CABLE DESCRIPTION: UNSHIELDED TWISTED PAIR DATA CABLE, 24 GAUGE ETHERNET GRADE 3, 2 PAIR, BELDEN #1227A
BLUE
BLUE WHITE
TB2 EGND X1- X1+ +12V GND +5V WHT
RED BLACK
+5V
READER PWR
ORANGE
RS485
DB25 (740-1012) OR DB9 (740-1022)
CABLE DESCRIPTION: 1. 2 METERS (4") AWG#26, 6 WIRES, INCLUDED WITH VC-485. (MAX LENGTH 60 METERS (200"))
ORANGE WHITE
BLUE
BLUE WHITE
Controllers.
KT-300
KT-300
*NOTE: CONNECT A 120 OHMS END OF LINE RESISTOR ON THE LAST KT-300
TB1
S/N
16V AC
+12vAUX
LK1- + LK2LOCK 12V
Over Corporate Network (LAN) If the master controller is used in a LAN-enabled corporate setting, use TCP/IP-to-RS-232 converter (such as the Kantech IP Link or the Lantronix UDS-1100 communication interface) to connect the controller to the corporate network. This method uses existing wiring for data exchange between EntraPass and the controllers. The diagram on the left shows how to connect a DB-9 to RJ-12 flat cable between the master controller and the converter. Consult Application Note DN1506 to learn how to set up the communication interface.
For remote sites If the master controller is used in remote areas, modems must be used to send and receive access control data over telephone lines. For this application Kantech supports US Robotics 56K external Sportster modems at both ends of the communication line. As shown on the right, a modem connects to the master controller only using a DB25 to RJ-12 flat cable. For dial-up communication settings via software, refer to your communication settings.
EntraPass Dial-Up Setup with KT-300
EntraPass Gateway
US Robotics Sportster External 56k Part# DU-MODEM-RS
Adaptor modem to KT-300 (DB-25) Part #740-1035
Phone Jack
Remote Modem Dipswitch Settings 1, 6 UP
US Robotics Sportster External 56k Part# DU-MODEM-HOS Phone
Jack
Flat cable Part #CAB-15
Phone Line
VITAL
Host Modem Dipswitch Settings 1, 2, 6 UP
RJ12 CONNECTOR Phone Jack KT-300 MASTER
(Optional Host Modem to receive alarms only)
DN1315-0707
9
Powering the KT-300
Install 120 / 220VAC / 16VAC, 40 VA, class 2 transformer. The KT-300 Controller must be powered by a 16VAC/40VA class 2 wire-in or plug-in transformer. After you have completed all the necessary steps, you may power the KT-300 Controller. Once powered, check the VITAL LED status indicator to determine the status of communication and other vital parameters. Consult the troubleshooting section for VITAL LED behavior identification. If the AC supply is removed, the 12 Volt 7 A/h led-type backup battery will support normal operation for up to 12 hours if fully charged. Internal battery verification will cutoff battery power if the battery voltage level falls below 9. 5 Volts.
NOTE: The KT-300 Controller will not start on battery alone. NOTE: Power should only be applied to the unit when all connections are completed and
RED BLACK
BAT
AC LED
KT-300
TB1
16V AC +12vAUX LK1- + LK2- RED BLK YEL GRN LOCK 12V COMBUS
PLUG-IN ALSO AVAILABLE DO NOT CONNECT TO RECEPTACLE CONTROLLED BY A SWITCH
120 / 220 VOLTS 40VA CLASS 2 (WIRE-IN)
tested.
SEALED RECHARGEABLE BATTERY 12 VOLT 7 AMP/h
KANTECH PART # KT-BD7-12
12 V BATTERY 7Ah MAXIMUM
Installing Combus Modules
Introduction to Combus Modules The Combus terminals on the KT-300 Controller are used to connect expansion modules to add more inputs, outputs, relays and LCD time and date display. The four Combus terminals of the main panel must be connected to the four Combus terminals or wires of all modules. Four expansion modules can be connected to KT-300's Combus (more specifications on each of these modules can be found later on in this document. ): · KT-PC4108 - 8-Zone input expansion module · KT-PC4204 - 4-Relay/Power supply expansion module · KT-PC4216 - 16-Zone output expansion module · KT3-LCD - Kantech LCD keypad module Combus Specifications The Combus provides 500 mA at 12 Volts (13. 85 VDC). Each loop (module to KT-300) cannot exceed 300 m (1, 000 feet) and the total maximum cable length of all connected loops cannot exceed 1, 200 m (4, 000 feet). For example: · Only four wireruns at 1, 000 feet from the KT-300. · Only ten wireruns at 400 feet from the KT-300 Shielded wire should only be used in areas with excessive RF noise of electromagnetic interference. [. . . ] The VITAL LED will flash 3 beats at a time as soon as the controller communicates with the PC. VITAL LED status indications
LED BUZ RL1 C AUX INPUTS 7 8 LED BUZ OUTDOOR 2 OUTDOOR 1
Default Initialization
RL2
REX
5
REX DOOR C
DOOR C
Communication status and other vital controller parameters can be obtained from VITAL LED pulsations. This information is particularly useful when connecting the controller to the rest of the access control system. Consult the KT-300 Controller Wiring Diagram on page 18 to locate the VITAL LED. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KANTECH KT-300
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KANTECH KT-300 will begin.