User manual JVC DLA-X5000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JVC DLA-X5000. We hope that this JVC DLA-X5000 user guide will be useful to you.


JVC DLA-X5000 : Download the complete user guide (551 Ko)

Manual abstract: user guide JVC DLA-X5000

Detailed instructions for use are in the User's Guide.

[. . . ] 2015D039 D-ILA® Projector DLA-X550R/X5000/XC5890R/RS400 Series DLA-XC6890 Series DLA-X750R/X7000/XC7890R/RS500 Series DLA-X950R/X9000/RS600/PX1 Series JVC External Control Command Communication Specification Ver. Projector Division (*)D-ILA is the trademark of JVCKENWOOD Corp. Document No. PJ06030001B Contents 4. 7. 2 Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 CONTENTS 1 OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] For the details of the remote control codes, see the key code specifications of each model. Command code Table 4-7 REMO CMD HEX 0x52 0x43 'R' ASCII 'C' Function Remote control pass-through [Remote Code] Operation Reference Parameters Data length: 4 Table 4-8 REMO CMD DATA HEX 0x30 ~ 0x39 0x41 ~ 0x46 ASCII '0' ~ ’9’ 'A' ~ ’F’ Operation Remote control code setting Remote control code setting The remote control code specification is in hexadecimal digits. The operation transition with the remote control codes is the same as from the user remote control. For the details of the remote control codes, see the key code specifications. 15 / 47 2015D039 PJ05030305B 4 Command control 4. 4. 1 Operation Use the command as shown in the following examples. Purpose: To display MENU screen by press the “MENU” of remote control code [0x732E]. (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x21 0x89 '!'(Operation) PJ 0x01 Individual : 1 0x52 'R' 0x43 'C' 0x37 '7' 0x33 '3' 0x32 '2' 0x45 ‘E' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ← Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x52 'R' 0x43 'C' 0x0A End (3) The projector produces a MENU screen. By the above exchange, the MENU screen can be produced. 16 / 47 2015D039 PJ05030305B 4 Command control 4. 5 Setup [SetUp] Used to change the initial setting. Command code Table 4-9 SETUP CMD HEX 0x53 0X55R ASCII 'S' 'U' Function Initial setting [SetUp] Parameters Data length: No regulation Sub command table (Mandatory command only) Table 4-10 SETUP CMD SUB Reference Operation HEX ASCII Function Last Memory 0x52 0x52 0x53 0x43 'R' ‘R’ 'S' ‘C’ Switch the external command protocol Switch the IR code control No No - It consists of “Sub command” + “Setting”. The Sub command consists of ASCII character two bytes. Sub commands parameters are as follow. Parameters when the Sub command is [0x52, 0x53] : Data length 1 HEX 0x31 ASCII ‘1’ Operation Compatible command system Parameters when the Sub command is [0x52, 0x43] : Data length 1 HEX 0x30 0x31 ASCII ‘0’ ‘1’ A code(0x73) B code(0x63) Operation 17 / 47 2015D039 PJ05030305B 4 Command control 4. 5. 1 Operation Use the command as shown in the following examples. Purpose: To switch External control command to compatible command protocol. (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x21 0x89 '!'(Operation) PJ 0x01 Individual : 1 0x53 'S' 0x55 'U' 0x52 'R' 0x53 'S' 0x31 Compatible command protocol:1 End 0x0A (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ←Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x53 'S' 0x55 'U' 0x0A End (3) The projector switches external command protocol to Compatible command protocol. By the above exchange, the projector switches to Compatible command protocol. Operation on projector screen None 18 / 47 2015D039 PJ05030305B 4 Command control 4. 6 Gamma data of Gamma table “Custom 1/2/3” [GammaRed, Green, Blue] Used for sending operation of the gamma data when the Gamma table is Custom, and referencing the gamma data of the projector. Target of switching and referencing is followed by setting value of the Gamma bank. Command code Table 4-11 GAMMA DATA CMD HEX 0x47 0x47 0x47 0x52 0x47 0x42 'G' 'G' 'G' ASCII 'R' 'G' 'B' Function Gamma data of the gamma table ”Custom1/2/3” (Red) [GammaRed] Gamma data of the gamma table ”Custom1/2/3” (Green) [GammaGreen] Gamma data of the gamma table ”Custom1/2/3” (Blue) [GammaBlue] Operation Reference Parameters Data length: 512 The gamma data has 256 adjustment points composed of binary data. The byte order is little endian. When the projector is not powered on and it receives the command, the projector ignores the command and does not respond. When the gamma table of the projector is not “Custom1”, ”Custom2” or ”Custom3” and the projector receives the command, the projector ignores the command and does not respond. When the projector receives a gamma data by operation command, the projector saves the gamma data on proper area of EEPROM immediately. If the projector receives gamma data larger than 512 bytes, it is judged as invalid data and the projector does not respond. The curve is combination of the curve on the OSD and the table (Normal/A/B/C/D) in the video processor. 19 / 47 2015D039 PJ05030305B 4 Command control 4. 6. 1 Operation Use the command as shown in the following examples. Purpose: To send red gamma data of the gamma table “Custom1/2/3” to the projector. (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x21 0x89 '!'(Operation) PJ 0x01 Individual : 1 0x47 'G' 0x52 'R' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ←Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x47 'G' 0x52 'R' 0x0A End (3) The external controller transmits 512 bytes of binary data to the projector. (4) If the projector receives data (3) above and the command receipt was normal, an ACK is returned from the projector as follows. 4: ←Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x47 'G' 0x52 'R' 0x0A End 4. 6. 2 Reference Use the command as shown in the following examples. Purpose: To confirm the green gamma data of the current gamma table “Custom3”. (Current Gamma bank: Custom3) (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x3F 0x89 '?'(Reference) PJ 0x01 Individual : 1 0x47 'G' 0x47 'G' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ← Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x47 'G' 0x47 'G' 0x0A End (3) The projector transmits 512 bytes binary data to the external controller. 4. 7 Panel Alignment (zone) Data [Panel Alignment(Zone) Red, Blue] Used for transmitting operation and referencing Panel Alignment (zone) data 20 / 47 2015D039 PJ05030305B 4 Command control Command Code Table 4-12 PANEL ALIGNMENT(ZONE) DATA CMD HEX 0x50 0x50 0x52 0x42 ‘P’ ‘P’ ASCII ‘R’ ‘B’ Function Data of Red [Panel Alignment(Zone)Red] Data of Blue [Panel Alignment(Zone)Blue transmitting referencing Parameters Data Length: 256 Horizontal and Vertical data of 11x11 Adjustment zone composed of binary data. Data is assigned by 2 bytes and its order is from Horizontal to Vertical. 121 (Adjustment zone) x 2 (Horizontal / Vertical) + 13 (reserved) =256 Byte Data No. [. . . ] 1: External controller → 0x3F 0x89 '?'(Reference) PJ 0x01 Individual : 1 0x50 ‘P’ 0x4D ‘M’ 0x44 ‘D’ 0x47 'G' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ← Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x50 ‘P’ 0x4D ‘M’ 0x0A End (3) The projector transmits 512 bytes binary data to the external controller. 42 / 47 2015D039 PJ05030305B 4 Command control (Example 4) Confirm Software Version Purpose: Confirm Software Version (1) Transmit the data from the external controller to the projector as follows. 1: External Controller → 0x3F 0x89 '?' (Reference) PJ 0x01 Individual:1 0x49 ‘I’ 0x46 ‘F’ 0x53 ‘S’ 0x56 ‘V’ 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ←Projector 0x06 0x89 ACK PJ 0x01 Individual : 1 0x49 ‘I’ 0x46 ‘F’ 0x0A End (3) Then, the Projector transmits Software version to the external controller. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JVC DLA-X5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JVC DLA-X5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.