User manual JBSYSTEMS LIGHT MICROL LED MANAGER V 1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JBSYSTEMS LIGHT MICROL LED MANAGER. We hope that this JBSYSTEMS LIGHT MICROL LED MANAGER user guide will be useful to you.


JBSYSTEMS LIGHT MICROL LED MANAGER V 1.0: Download the complete user guide (2939 Ko)

Manual abstract: user guide JBSYSTEMS LIGHT MICROL LED MANAGERV 1.0

Detailed instructions for use are in the User's Guide.

[. . . ] (R+G+B) with short-circuit protections 4 DMX channels needed: Ch1=red , Ch2=green , Ch3=Blue , Ch4=Dimmer/strobe. The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions This symbol means: Lamp Control Gear To prevent fire or shock hazard, do not expose this appliance to rain or moisture. [. . . ] This input receives instructions from a DMX-controller or from another Micro / Mini LED Manager when used in master/slave mode. DMX OUTPUT: 3pin female XLR-connector used to connect the Micro Led Manager with the next DMX appliance in the chain or with another Micro / Mini LED Manager when used in master/slave mode. The Micro / Mini LED Manager can also be used as controller for other LED projectors like for example "LED PAR56/64" 4. DIP SWITCHES: when used in DMX mode (DIP10 = OFF) you can set the DMX-starting address of the unit. When used in stand-alone mode (master, DIP10 = ON), you can use the DIP-switches to set different pre-programmed options. AUTO DMX ADDRESS BUTTON: see further to learn how to set the DMX address easily. OUTPUT TERMINALS: used to connect different 24Vdc common anode LED projectors. You can connect any 4pole electrical wire to connect the LED-projectors to this output. However to make life easier for you we suggest using the special CCM-50 cable (role = 50m). This external switch can be used to switch the general output of the Micro / Mini LED Manager on/off. (external blackout) See further for more information on how to connect the analog switch. WALL DIMMER INPUT: used to connect our LED WALL DIMMER, a small LED controller that fits in any standard "electrical wall box". See further for more information on how to connect the LED WALL DIMMER. STATUS LED: shows the status of the unit, should blink when DMX is detected. Connecting the optional LED WALL DIMMER: The LED WALL DIMMER is a small, easy to use, controller that can be installed in any standard wall connection box. This controller can be connected directly to the Micro / Mini LED Manager. The DMX-signal should be connected using a good quality balanced DMX-cable with good shielding. Remark 1: the Micro / Mini LED Manager should be set to DMX-address 001, using the traditional DIP switches (see "DMX addressing to learn how to do this) Remark 2: if you want to control more than 1 (Micro) LED manager, just connect the LED Managers together with the DMX in/outputs and put all DMX addresses to 001. Electrical installation in Master/slave-mode: You need to "daisy chain" the DMX in/outputs of 2 or more units with a good quality balanced cable The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. How to connect the LED-projectors to the output of the unit: Important: Switch the Micro / Mini LED Manager OFF before you install the LED-projectors!The maximum total load of the Micro Led Manager is 50W, spread over 3 colors: each of the 3 colors has a max. The maximum total load of the Mini Led Manager Mk2 is 100W, spread over 3 colors: each of the 3 colors has a max. [. . . ] You can only use the controls on the master unit, the controls on the slaves are disabled. Refer to the chapter "DIP SWITCH SETTINGS" to make yourself familiar with the various functions of the faders and buttons on the master unit. Connect the optional LEDCON-02 for remote control: In most cases the MICRO / MINI LED MANAGER will be installed on a wall, close to the LED-projectors. If you want to have easy access to its functions, you can connect the LEDCON-02 remote controller to the (first) Micro / Mini LED Manager. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT MICROL LED MANAGER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT MICROL LED MANAGER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.