User manual JBSYSTEMS LIGHT DLP6 V1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JBSYSTEMS LIGHT DLP6. We hope that this JBSYSTEMS LIGHT DLP6 user guide will be useful to you.


JBSYSTEMS LIGHT DLP6 V1.0: Download the complete user guide (2573 Ko)

You may also download the following manuals related to this product:

   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)
   JBSYSTEMS LIGHT DLP6 V1.1 (3206 ko)
   JBSYSTEMS LIGHT DLP6 V1.2 (3198 ko)

Manual abstract: user guide JBSYSTEMS LIGHT DLP6V1.0

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual EN Other languages are available on our website WWW. SYNQ-AUDIO. COM Copyright © 2008 by BEGLEC cva. Reproduction or publication of the content, even portions, in any manner, without express permission of the publisher, is prohibited. V1. 0 EN - DISPOSAL OF THE DEVICE Dispose of the unit and used batteries in an environment friendly manner according to your country regulations. FR - DÉCLASSER L'APPAREIL Débarrassez-vous de l'appareil et des piles usagées de manière écologique Conformément aux dispositions légales de votre pays. NL - VERWIJDEREN VAN HET APPARAAT Verwijder het toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften. DU - ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes. ES - DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais. PT - COMO DESFAZER-SE DA UNIDADE Tente reciclar a unidade e as pilhas usadas respeitando o ambiente e em conformidade com as normas vigentes no seu país. ENGLISH OPERATION MANUAL ENGLISH Check the contents: Check that the carton contains the following items: User manual DLP-6 unit CDROM with PC software Mains cable OPERATION MANUAL OPERATION MANUAL Thank you for buying this SYNQ product. To take full advantage of all possibilities, please read these operating instructions very carefully. ® DON'T FORGET TO REGISTER YOUR DLP-6. YOU WILL AUTOMATICALLY RECEIVE A SAFETY INSTRUCTIONS: CAUTION CAUTION: To reduce the risk of electric shock, do not remove the top cover. Refer servicing to qualified service personnel only. REMINDER WHEN NEW SOFTWARE UPDATES ARE AVAILABLE! SURF TO: WWW. SYNQ-AUDIO. COM/REGISTER/ FEATURES This unit is radio-interference suppressed. [. . . ] PHASE: turn the DIAL (4) to choose "+" (output in phase) or "-" (output in anti-phase) SOURCE SELECT: turn the DIAL (4) to select the input that should be linked to the selected output: OFF: selected output is not used. OUTPUT PARAMETERS ­ DELAY The display shows the delays in meter, milliseconds and foot. SMALL STEPS: turn the DIAL (4) to adjust the delay in small 21µs steps. BIG STEPS: press the /buttons (9&10) to adjust the delay in big 5, 20ms steps. OUTPUT PARAMETERS ­ EQUALIZER All output channels have a 4band EQ, each band can have different settings. Use the /buttons (9&10) to jump between the different parameter settings: ON/OFF: for each band you can choose if it should be on or off, simply turn the DIAL (4) to select. EQ BAND: turn the DIAL (4) to choose the desired EQ-filter: you can choose 1 to 4. EQ TYPE: turn the DIAL (4) to choose the desired EQ-filter type: PEQ: Parametric equalizer, with the following parameters: o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0, 1dB steps. o FREQ: turn the DIAL (4) to adjust the center frequency from 19, 7Hz to 20kHz. SYNQ® 5/14 DLP-6 SYNQ® 6/14 DLP-6 ENGLISH OPERATION MANUAL ENGLISH OPERATION MANUAL o BANDWIDTH: turn the DIAL (4) to change from 0, 016 (narrow) to 4, 000 (wide). LS1: Low-shelf 6dB, with the following parameters: o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0, 1dB steps. o FREQ: turn the DIAL (4) to adjust the frequency from 19, 7Hz to 2kHz. LS2: Low-shelf 12dB, with the following parameters: o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0, 1dB steps. o FREQ: turn the DIAL (4) to adjust the frequency from 19, 7Hz to 2kHz. HS1: High-shelf 6dB, with the following parameters: o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0, 1dB steps. o FREQ: turn the DIAL (4) to adjust the frequency from 3886Hz to 21, 9kHz. HS2: High-shelf 12dB, with the following parameters: o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0, 1dB steps. o FREQ: turn the DIAL (4) to adjust the frequency from 3886Hz to 21, 9kHz. OUTPUT PARAMETERS ­ HIGH-PASS FILTER (CROSSOVER) All outputs are equipped with a fully adjustable high-pass filter. Use the /buttons (9&10) to jump between the different parameter settings: CUTOFF FREQUENCY: turn the DIAL (4) to adjust the frequency from 19, 7Hz to 21, 9kHz or to turn it OFF. FILTER TYPE: turn the DIAL (4) to select one of the filter types (Butterworth, Bessel or Linkwitz-Riley) and corresponding slopes (12dB/oct, 18dB/oct, 24dB/oct or 48dB/oct) OUTPUT PARAMETERS ­ LOW-PASS FILTER (CROSSOVER) All outputs are equipped with a fully adjustable low-pass filter. Use the /buttons (9&10) to jump between the different parameter settings: CUTOFF FREQUENCY: turn the DIAL (4) to adjust the frequency from 19, 7Hz to 21, 9kHz or to turn it OFF. FILTER TYPE: turn the DIAL (4) to select one of the filter types (Butterworth, Bessel or Linkwitz-Riley) and corresponding slopes (12dB/oct, 18dB/oct, 24dB/oct or 48dB/oct) OUTPUT PARAMETERS ­ LIMITER All outputs are equipped with a fully adjustable limiter. [. . . ] In the left upper corner you will notice the sign on the right, indicating that the software is not connected to the processor. Open the "CONFIG" menu and select the "RS-232" option. Normally you should choose "COM3" Open the "CONFIG" menu again and select "OnLine": a popup window will open where you have to select "DLP-6:2In6Out" If the software can connect to the processor than you should see the sign on the right. If this doesn't work, you should also select some other COM-settings and try again to establish a connection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT DLP6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT DLP6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.