User manual JANDY H05612

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual JANDY H05612. We hope that this JANDY H05612 user guide will be useful to you.


JANDY H05612 : Download the complete user guide (509 Ko)

Manual abstract: user guide JANDY H05612

Detailed instructions for use are in the User's Guide.

[. . . ] Installation and Operation Data Installation and Operation Manual JandyColors Digital Color Blending, Underwater Pool and Spa Lights ® WARNING H0561200C FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ spa service technician. Failure to follow warning notices and instructions may result in property damage, serious injury, or death. Page 3 Table of Contents Section 1. Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description and Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights NOTE The Jandy Pool and Spa Lights will not operate properly with light dimmers. Do not wire the Jandy Lights to any dimming circuitry. To the extent allowed by code and capacity of the electrical equipment, multiple Jandy Pool and Spa Lights may be controlled with a single switch so their colors will always be synchronized. Separate switches may be used to control the on/off and color functions of each Jandy Pool or Spa Light. It is recommended that these switches be located next to each other to facilitate simple color synchronization when desired. All switches must be operated at the same time to assure color synchronization otherwise the lights will work independently of each other. 5. 1 Wiring to an AquaLink® RS Control System The Jandy Pool and Spa Lights can be wired into the Jandy AquaLink RS control system to ensure simplified operation of the lights, as well as a means to synchronize the color change function. Connect the lights to one of the auxiliary relays in the Power Center. NOTE It is recommended to connect one light per relay so each light can be controlled separately. If there are more than four lights installed on one AquaLink RS system, ensure there is more than one auxiliary relay available in the Power Center. Refer to Figures 3 and 4 to connect the Jandy Pool and Spa Lights to the Power Center. CAUTION A Ground Fault Circuit Interrupter (GFCI) must be provided in this circuit. The conductors on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a GFCI. Refer to local codes for complete details. 120 VAC Power Supply 120V Jandy Light Black White Green Neutral Ground Ground GFCI Figure 3. 120-Volt Jandy Pool and Spa Light Wiring Diagram Page 12 NOTE The Jandy Pool and Spa Lights are available in 120-volt and 12-volt versions. If installing a 12-volt light, a 120-volt/12-volt step-down (AC) transformer must be used. For more information about 12-volt installations, refer to Section 8 of this manual. 120 VAC Power Supply 12V Jandy Light Black White Green Black White Green Neutral Ground Ground GFCI 120V/12V Transformer Figure 4. 12-Volt Jandy Pool and Spa Light Wiring Diagram 5. 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be wired into a basic time clock to automatically turn on the lights at a predesignated time. Refer to Figure 5 to connect the lights into the clock. Clock Motor Neutral 120 V Supply Line GFCI Ground A 1 2 Black White Green 120V Jandy Light Ground Figure 5. Wiring the Jandy Pool and Spa Light to a Time Clock Page 13 Section 6. Jandy Pool Light and Jandy Spa Light Operating Instructions 6. 1 To Operate the Light Turn the light ON. The first time the light is turned on, the color change sequence begins with the Alpine White color set and then continues through the sequence. Each color set is active for approximately 20 seconds before the light transitions to the next color (see Table 1). Table 1. Pool and Spa Lights Color Change Sequence Sequence Order 1 2 3 4 5 6 7 8 9 10 Color Set (Consists of Two Colors in Each Light) Alpine White (first cycle only) Sky Blue Cobalt Blue Caribbean Blue Spring Green Emerald Green Emerald Rose Magenta Garnet Red Violet (color remains active approximately 4 minutes) NOTE When the light is first turned on, the sequence ends at Violet and at the next rotation, starts at Sky Blue. When the light is turned off, it will remain in the color set that is currently active. When the light is turned back on, the color change sequence will start with the color set that was last active. For example, if the light is turned off when Cobalt Blue color set is active, then Cobalt Blue will be the first color set in the change sequence when the light is turned on again. 6. 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change. Wait 10 seconds before turning the light off so that the color will not reset. NOTE If a specific color is not locked on during first cycle of colors, the light will continue to follow the color change sequence. If you encounter a dimmed light, the light was probably turned off during in the middle of the color transition. [. . . ] warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: · AquaLink® RS units installed with Jandy Surge Protection Kits will be covered for two years. · NeverLube® valves are warranted for the life of pool and/or spa on which they were originally installed. · AquaPureTM Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis. This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JANDY H05612




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual JANDY H05612 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.