User manual ITI CARETAKER PLUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ITI CARETAKER PLUS. We hope that this ITI CARETAKER PLUS user guide will be useful to you.


ITI CARETAKER PLUS : Download the complete user guide (3608 Ko)

Manual abstract: user guide ITI CARETAKER PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. FCC ID: B4Z-787E-SIMON ACTA Part 68 This equipment complies with Part 68 of the FCC Rules. [. . . ] The Downloader Code must match the downloader access code in the ToolBox account to perform ToolBox sessions. To set Downloader Code, press: Add--Option #--09--5-digit code--DONE. To delete Downloader Code (return to default), press: Delete--Option #--09--DONE. Note The downloader code should always be changed from the default setting to avoid competitor theft. Option 10: Entry Delay (Default = 030 sec) Determines how much time the user has to disarm the system after entering the armed premises through a designated delay door, before an alarm occurs. Beeps sound during the entire delay time to remind the user to disarm the system. When turned on, the Entry Delay can be set from 005-254 seconds (030-254 if SIA Limits Option 69 is on). To set Entry Delay, press: Add--Option #--10--3-digit delay time--DONE. To reset Entry Delay (return to default), press: Delete--Option #--10--DONE. Note For UL listed systems, the entry delay must not exceed 45 seconds. Simon Security System 22 Option 11: Exit Delay (Default = 060 sec) Determines how much time the user has to leave the premises through a designated delay door after arming the system. Beeps sound after arming the system to remind the user to leave the armed premises. If a delay door is opened after the Exit Delay expires, the Entry Delay begins. If the user arms the system with No Delay and opens a delay door after the Exit Delay expires, an alarm occurs. When turned on, the Exit Delay can be set from 005-254 seconds (045-254 if SIA Limits Option 69 is on). For UL 985 and 1635 listed systems, RF Timeout must be set to 4 hours (04). For UL 1023 listed systems, RF Timeout must be set to 24 hours (24). The timeout can be set from 02-24 hours. To reset RF Timeout (return to default), press: Delete--Option #--19--DONE. Option 20: Manual Phone Test (Default = on) Determines whether the user can perform a manual phone test to verify communication to a central station/pager (on), or not (off). To turn on Manual Phone Test, press: Add--Option #--20--DONE. 25 Simon Security System To turn off Manual Phone Test, press: Delete--Option #--20--DONE. Option 21: Opening Reports (Default = off) Determines whether the panel sends opening reports to a central station or pager whenever the system is disarmed (on), or not (off). To turn off Opening Reports, press: Delete--Option #--21--DONE. Option 22: Closing Reports (Default = off) Determines whether the panel sends closing reports to a central station or pager whenever the system is armed (on), or not (off). To turn off Closing Reports, press: Delete--Option #--22--DONE. Option 23: Force Armed Report (Default = off) Determines whether the panel sends a force armed report to a central station or pager if the user bypasses protesting sensors (indirect bypass) when arming the system (on), or not (off). To turn off Force Armed Report, press: Delete--Option #--23--DONE. Option 24: AC Power Failure Report (Default = off) Determines whether the panel sends AC power failure reports to a central station or pager after the programmed time expires (on), or not (off). When the panel is without AC power for 30 seconds, the panel LEDs turn off. When the panel is without AC power for the programmed time, an AC power failure is reported. The panel reports an AC power restoral when AC power returns to the panel. Note For UL listed systems, AC Power Failure must be set to 15 minutes. The time can be set from 5-254 minutes. To turn on AC Power Failure Report, press: Add--Option #--24--005 - 254--DONE. [. . . ] 04 Fixed auxiliary: 24 hour auxiliary sensor 05 Fixed Auxiliary: 24 hour emergency button. Siren shut off confirms CS report 06 Portable Auxiliary: 24 hour portable auxiliary alert button 07 Portable Auxiliary: 24 hour portable auxiliary button. Siren shut off confirms CS report 08 Special Intrusion: such as gun cabinets and wall safes. 10 Entry/Exit Delay: Entry/Exit Delay that require a standard delay time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ITI CARETAKER PLUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ITI CARETAKER PLUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.