User manual IROX HT78

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IROX HT78. We hope that this IROX HT78 user guide will be useful to you.


IROX HT78 : Download the complete user guide (307 Ko)

You may also download the following manuals related to this product:

   IROX HT78 (312 ko)
   IROX HT78 (306 ko)
   IROX HT78 (298 ko)
   IROX HT78 (2877 ko)

Manual abstract: user guide IROX HT78

Detailed instructions for use are in the User's Guide.

[. . . ] is active This key is inactive when CLEAR - Hold pressed for 3 seconds: For the channel active and flashing on the display ( reset. , CH1 . . . . CH5), the MAX/MIN memory is View from behind (with battery lid opened) Battery compartment 2 x 1. 5 batteries of the size UM-3 resp. `AA' °C/°F switchover When the battery compartment is opened, you will find above the CE label a press button with which the temperature measurement unit displayed on the LCD can be changed from ° C to ° F and vice versa at any time and independently of the setting on the sensor. The key can be operated with a sharp object (paper clip, tip of a pen, etc. ) (single short pressing of the key). 3. [. . . ] The element to be set starts flashing in the display: With the + and - keys, you can now make a setting for as long as the element is flashing. You can now move from setting to setting with a single brief pressing of the SET key. The procedure of the settings is as follows: - Date setting (year ---> month ---> day) - Time format: 24 hours or 12 hours (AM/PM) display - Time setting (Hour ---> Minute) You cannot directly interrupt the setting process. You then therefore go through the entire selection of settings with the SET key until the time of day reappears again after the minutes setting with the flashing `:' In the time. If you do not press a key in setting mode for more than 2 minutes, the settings made will be adopted and the time of day displayed. 5. 2 THERMOMETER WITH ALARM With regard to operation, the HT78 is in a 'sleep mode' when no key is pressed for more than 2 minutes. This status is then recognised by the fact that on the left-hand side of the display neither the symbol nor the number in the channel display is flashing. In such a case, the operation is activated by pressing one of the 3 keys. The corresponding symbol then flashes in the field to be operated ( or `CH' with corresponding number). The HT78 measures the temperature directly and also receives the measurements of up to a maximum of 5 IROX thermo radio sensors. In the two information windows ) the temperature currently measured is displayed in °C (or °F). (radio sensors CH1. . . . 5 and The following operations can be made in this function: 5. 2. 1 Reading of the temperature from each channel Activate the CHANNEL key briefly to jump from channel to channel. The next channel is displayed with each press of the button and activated for other operations. The sequence of the activation is --> CH1 ---> CH2 --> CH3 --> CH4 --> CH5 --> --> CH1 --> etc This is independent of whether a radio sensor is available in the system or not. Note: The measurement is always depicted in the lower window; the channels 1-5 one after the other in the middle window. 5. 2. 2 MIN/MAX memory a) With the `MEMORY' key you can read the Max/Min memory of the active channel by pressing it briefly (flashing symbol or CH1 . . . . The corresponding MIN/MAX value is displayed together with the date and the time of the recording (`time stamp'). 4 seconds in the following sequence on the display: - Maximum (=highest) temperature `MAX' - Minimum (=lowest) temperature `MIN' - Back to display of the current measurement The sequence can also be made manually by pressing the MEMORY key. If no data are available, lines appear. b) Reset of the MIN/MAX memory If you hold the CLEAR key pressed for approx. 3 seconds, the MIN/MAX memory values of the active channel (flashing or CH1 . . . . symbol 5. 2. 3 Measurement unit °C or °F You can change the unit of temperature from °C to ° F (see Chapter 2. 2). The setting on the display appliance or the sensor is to be made independent of one another and only affects the display of the corresponding device. 5. 2. 4 Temperature alarm The temperature alarm function is programmed individually per channel ( / CH1. . . . [. . . ] As soon as it is returned to a warm environment the device will function normally. - Please keep the user's manual and other documents delivered with the device stored carefully so that you can reference them at a later point if necessary. - Please also remember that old batteries should not be disposed of with household waste but should be handed in at the designated collection centres. - Important: With all Irox appliances, all disposal fees in Switzerland (vRG; advance recycling fee) and in the EU (WEEE) have been paid. 8. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IROX HT78




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IROX HT78 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.