User manual IROX BAROBEAM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IROX BAROBEAM. We hope that this IROX BAROBEAM user guide will be useful to you.


IROX BAROBEAM : Download the complete user guide (367 Ko)

You may also download the following manuals related to this product:

   IROX BAROBEAM (436 ko)
   IROX BAROBEAM (407 ko)
   IROX BAROBEAM (398 ko)

Manual abstract: user guide IROX BAROBEAM

Detailed instructions for use are in the User's Guide.

[. . . ] 44 2. 3 Remote sensor (Temperature). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Set-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extended operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 4. 1 Weather forecasts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] You now have 8 seconds to begin setting your local sea level using the +/buttons. When you have reached the desired height wait 8 seconds, then the device will start receiving data from the remote sensor and then the time from the time signal transmitter DCF77. Wait until all data (time and temperature) are indicated correctly on the device. From now on your device will function without you ever having to push another button. In chapter 4 you will find details for optional settings and also information on certain procedures. 4. 3 Trend indicator You have a total of 4 different trend indicators available, 2 of them simultaneously: 1- The large Weather Icon on the upper right of the display shows the forecast for the next 12-24 hrs. On the left side of that, underneath the pressure indicator, you will see a smaller icon with 3 arrows. The small icon indicates the forecast 12 hours before, thus giving you additional information regarding the forecast development. 4. EXTENDED OPERATION All operations on the device are carried out by pressing buttons. In these chapters you will find additional information about the functions 2- Graphic pressure history - One bar equals 1 hPa. - If you change the pressure units (from hPA to inHG), the graph will remain the same. The only thing that vanishes is the scaling on the right side of the graph with the -4 to +4 hPa. In between the active receptions the time runs on integrated quartz (this is a factory setting which is reactivated after every battery replacement) 2- Strictly as a quartz clock Move to set mode with the SET TIME receiving is activated. This means the radio button you move to the next setting. With this search procedure the device searches the same sensor that was already previously logged in. If you replace the batteries in the sensor, the sensor gives itself a new code and will then no longer be recognized by the display unit. You can resolve this problem by: - removing the batteries from the display unit and replacing them with new ones or - if the batteries are still O. K. , repeating the logging in procedure as described above by pressing and holding the SYNC button and while the wave icon is blinking press and hold the SYNC button again for 3 seconds. The temperature indicator will start to blink indicating that a new sensor is being searched for and will be logged in. INDICATION AND CONDITIONS OF THE COMFORT ZONE The COMFORT ZONE is indicated for the room where the main device is positioned. There are 5 conditions COMFORT, WET, DRY, HOT and COLD. With the +/- buttons you can make changes to the setting, with the SET TIME The setting options vary depending on operating mode "On" or OFF" Operating mode 1 ­ Radio controlled clock on = On - Time indication format: 24 hours or 12 hours resp. AM/PM - Time zone setting (standard =0, adjustable from -9 to +9 hours): Time deviation as compared with the received radio time as the respectively valid time in Central Europe (Germany, France, Switzerland, Denmark etc. ). If you set a time zone "ZONE" and the accordingly corrected time will appear on the time display. The output of rechargeable batteries is often not sufficient for our devices. Issue Display unit Symptom Radio controlled clock does not receive signal Solution Reposition the device. Replace batteries (in both devices!) Display unit/ Remote sensor Remote sensor is not being received Check the position of the sensor. [. . . ] Preferable are measuring points in the shade, for example under a weather protected roof with good air circulation. · The remote sensor can be stood or mounted vertically on a wall. To do so please use the provided wall bracket, this should be mounted on the wall with a screw not with a nail. · Ideally the sensor should be placed 1. 25m (4 feet) over the ground respectively grass surface. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IROX BAROBEAM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IROX BAROBEAM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.