User manual INTERMATIC PG2500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTERMATIC PG2500. We hope that this INTERMATIC PG2500 user guide will be useful to you.


INTERMATIC PG2500 : Download the complete user guide (47 Ko)

Manual abstract: user guide INTERMATIC PG2500

Detailed instructions for use are in the User's Guide.

[. . . ] Refer to the wiring configurations and voltages on page 2 and 3 for additional information. Remove the knockout from the power bus, load center or equipment panel that will position the SPD for the shortest wire lead distance. Note that the shorter the lead length between the SPD and the connection point, the better the protection. [. . . ] If remote monitoring is used, remove the ½" knockout and connect wire leads to the terminal strip located in the monitoring section of the PanelGuard cabinet. Be sure to comply with local and national wiring codes for the voltage of the monitoring circuit. Observe the suggested torque values published by the manufacturer when circuit breakers or separate disconnect devices are used. Close and secure the hinged cover using the locking bolts provided with the cover. Make sure that each Protection Status indicator on the PanelGuard is ON. If not, turn power off and recheck each installation step listed above. If not, turn power off and recheck each installation step listed above. Verify that the audible alarm sounds and the alarm relay changes state. Verify that the audible alarm sounds and the alarm relay changes state. For troubleshooting assistance, call Intermatic at 800-391-4555. 4. 20. 21. WIRING CONFIGURATIONS 120 VAC Single Phase Transformer Secondary Load Center or equipment L1 Black VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE PanelGuard Line to Neutral Line to Ground 120 120 N G White Green Use of Circuit Breakers is optional 120/240 VAC Single (Split) Phase Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 L2 N G Black Black White Green PanelGuard Line to Line Line to Neutral Line to Ground 240 120 120 Use of Circuit Breakers is optional 120/208 VAC Three Phase WYE Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 Black L2 Black L3 Black N G White Green PanelGuard Line to Line Line to Neutral Line to Ground 208 120 120 Use of Circuit Breakers is optional 120/240 VAC Three Phase Delta High Leg Delta Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 Black L2 Red L3 Black N White G Green PanelGuard Line to Line Line to Neutral High Leg to Neutral Line to Ground High Leg to Ground 240 120 208 120 208 Use of Circuit Breakers is optional 277/480 VAC Three Phase WYE Transformer Secondary Load Center or equipment L1 Black L2 Black L3 Black N G White Green VOLTAGE CONFIGURATION CONFIRMATION PanelGuard MODE VOLTAGE Line to Line Line to Neutral Line to Ground 480 277 277 Use of Circuit Breakers is optional 480 VAC Three Phase DELTA Transformer Secondary Load Center or equipment L1 L2 L3 Black Black Black Green VOLTAGE CONFIGURATION CONFIRMATION PanelGuard MODE VOLTAGE Line to Line Line to Ground 480 480 G Use of Circuit Breakers is optional Alarm relay for remote monitoring Violet ­ n/c PanelGuard Brown - c Common - Brown Orange ­ n/o Normally Open - orange Normally Closed - Violet Normal operating condition ­ relay energized Violet ­ n/c Brown - c Orange ­ n/o AC lead connections Alarm relay connections Alarm condition ­ relay not energized Alarm Switch functions Audible alarm is silent and alarm relay is energized for proper operation. If protection is lost or reduced, the audible will sound and the alarm relay will change state. TEST POSITION: Audible alarm will sound and the alarm relay will change state. SILENCE POSITION: Audible alarm is silenced and alarm relay is not energized during alarm conditions. When protection is restored, the audible will sound and the alarm relay will energize to change state. NORMAL POSITION: TEN YEAR LIMITED PRODUCT WARRANTY For PanelGuardTM2500 SURGE PROTECTION DEVICES (1) What Is Covered By This Limited Warranty Repair or Replacement of Product Intermatic Incorporated ("Intermatic") warrants to the original purchaser only, the Intermatic PanelGuard 2500 Series Surge Protection Device shall be free from defects in material or workmanship for a period of ten years from date of purchase. If the purchaser discovers a defect in material or workmanship, the purchaser must promptly submit a warranty claim. [. . . ] TO THE EXTENT ALLOWED BY LAW, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY. (4) Limitation of Remedies In no case shall Intermatic be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict tort, or any other legal theory. Such excluded damages include, but are not limited to, damage to software, loss of data, loss of profits, loss of savings or revenue, loss of use of the Product or any associated equipment, cost of capital, cost of any substitute equipment, facilities or services, downtime, the claims of third parties including customers, damage to property and personal injury. Some states do not allow limits on warranties or on remedies for breach in certain transactions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC PG2500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC PG2500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.